Battery 12V 9Ah VRLA/AGM for Mortara ELI 350 Electrocardiograph | SLA Faston F1 · OEM Replacement 4800-010 · Ref. 88881113

24,00 €

12 V / 9 Ah sealed lead-acid (VRLA/AGM) battery for Mortara ELI 350 electrocardiograph, with Faston F1 terminals and direct installation in the device compartment reusing the original wiring. Rechargeable, maintenance-free, high-capacity replacement designed to keep your ECG operational throughout the clinical day in cardiology, emergency and primary care. Cell format NP9-12 / NPX-35 (151 × 65 × 94 mm), reference Cahnos 88881113. Quick replacement, extended battery life and stable performance in continuous recording.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
88881113

Description

1. The reliable power source for your Mortara ELI 350

This 12 V, 9 Ah battery is the recommended power supply replacement for the Mortara ELI 350 electrocardiograph, a resting ECG device widely used in cardiology clinics, emergency departments, occupational medicine and diagnostic centres. Its sealed lead-acid technology (VRLA/AGM) ensures a stable, leak-proof power supply with the autonomy needed to complete successive examinations without mains dependency. This high-capacity, maintenance-free, rechargeable replacement restores full operability to the device in minutes at a very competitive cost compared to the official replacement.

2. Technical explanation: how this battery works

The cell uses valve-regulated lead-acid (VRLA) chemistry with absorbed glass mat (AGM) electrolyte, making it sealed, rechargeable and suitable for use in portable medical devices. It supplies a nominal voltage of 12 V with a capacity of 9 Ah at a 20-hour rate, sufficient to power the ECG acquisition, display, interpretation and thermal printing of the ELI 350 during clinical activity. Its sealed construction allows spill-proof installation, and its standard NP9-12 / NPX-35 cell format (151 × 65 × 94 mm) with Faston F1 terminals fits the equipment’s battery compartment, reusing the original wiring. Like all VRLA cells, it offers a typical design life of 3 to 5 years under nominal use and charge conditions, with good recovery after moderate discharges.

3. Technical Specifications

Characteristic Specification
Reference Cahnos (SKU) 88881113
OEM reference of the equipment it covers Mortara Instruments 4800-010 / SERV-ASSY-171-01 (documented fleet of ELI 350)
Battery type Sealed lead-acid (VRLA / AGM), maintenance-free
Nominal voltage 12 V
Capacity 9 Ah (20-hour rate)
Chemistry Valve-regulated lead-acid, absorbed electrolyte (AGM)
Terminals Faston F1 (0.187 inches / 4.75 mm)
Dimensions (L × W × H) 151 × 65 × 94 mm (NP9-12 / NPX-35 cell format; verify equipment compartment)
Approximate weight 2.5 kg
Rechargeable Yes
Compatible equipment Mortara ELI 350 Electrocardiograph
Use Power supply for diagnostic equipment (ECG) in hospitals, clinics and diagnostic centres
Estimated life 3-5 years under nominal conditions (typical VRLA)
Installation Direct in the battery compartment, reusing the unit’s wiring
Presentation Unit

4. Equivalences and Cross-References

The cell that powers the Mortara ELI 350 corresponds to the standard sealed lead-acid 12 V / 9 Ah format with Faston terminals, equivalent to generic reference cells Yuasa NP9-12 / NPX-35. The references from other brands listed below belong to the same product category (12 V, 9 Ah VRLA battery with Faston terminal) and have been cross-checked in manufacturer datasheets and specialised distribution; they are classified as comparable by category, not 1:1 interchangeable, and require verification of terminal, dimensions and polarity against the specific device before replacement.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
CSB / Vision Battery CP Series (high discharge rate) CP1290H-FR Comparable by category (not interchangeable 1:1) Sealed lead-acid battery 12 V / 9 Ah with AGM technology and flame-retardant (FR) casing, Faston terminals, 151 × 65 × 94 mm. Confirmed in manufacturer official datasheet (Vision) and documented as replacement for Mortara ELI 350 in specialised distribution (Beck-Lee). Verify terminal and dimensions of the batch.
Power-Sonic PS series (general purpose SLA) PS-1290 Comparable by category (not interchangeable 1:1) SLA battery 12 V / 9 Ah with AGM technology, Faston terminals (F1/F2 depending on version), 151 × 65 × 94 mm. Confirmed in manufacturer official datasheet. Same electrical performance; verify terminal orientation and wiring.
GS Yuasa (Yuasa) NP / NPX Series NP9-12 / NPX-35 Comparable by category (not interchangeable 1:1) Sealed lead-acid cell 12 V / 9 Ah with Faston terminals, 151 × 65 × 94 mm (the NPX-35 is the high discharge rate variant). Confirmed in manufacturer official datasheet and cited in cross-reference tables for the ELI 350 in specialised distribution. Verify F1 terminal of the batch.

Additionally, in cross-reference tables from specialised distribution for the Mortara ELI 350 (OEM 4800-010 / SERV-ASSY-171-01) the codes Alpha Source AS35663 / SLA1075, OSI Batteries NPX-35A and MK Battery BMED00339 appear; their full attributes could not be cross-checked in manufacturer official datasheets (OSI Batteries declares for this device a battery of 12 V / 8.5 Ah), therefore they are not included as an equivalence row. There is no equivalence table validated by the device manufacturer authorising third-party batteries; consult the technical department before use in a tender. Before replacement, the following must be verified one by one: voltage (12 V), capacity (9 Ah), chemistry (sealed lead-acid VRLA/AGM), terminal type (Faston F1, 0.187 inch) and compartment dimensions (NP9-12 / NPX-35 cell format of 151 × 65 × 94 mm).

5. Selection tips and variants of interest

  • Identify the exact model of your device: this 12 V / 9 Ah battery is the one indicated for the Mortara ELI 350. Do not replace it with cells of other capacity or voltage without prior technical validation: each model in the family supports a specific voltage and capacity.
  • Beware of 7 Ah cells: some distribution tables list 7 Ah cells (PS-1270-F1) for ELI 280 / ELI 350 / ELI 380 due to shared case format; they are not safely interchangeable with the 9 Ah without validating the compartment and service autonomy requirements.
  • Check the terminal: the device requires Faston F1 terminals (0.187 inch / 4.75 mm). Do not replace with cells of other terminal sizes or with integrated wiring without prior validation.
  • Prevention and maintenance: VRLA cells self-discharge slowly at rest; if the device is to remain switched off for long periods, recharge it periodically to prevent the voltage from dropping below the recovery threshold (≈10.5 V). Replace the battery when recording autonomy decreases noticeably or the device warns of low battery.
  • Variants of the same Mortara family available at Cahnos: 12 V / 7 Ah battery for ELI 380 (ref. 88889604), 12 V / 2.3 Ah battery for ELI 250 (ref. 88889688), 12 V / 1.2 Ah battery for ELI 50 (ref. 88889503) and 6 V / 1 Ah battery for ELI 100 (ref. 88888936). Do not interchange these references between models.
  • For institutional orders, tenders or ongoing supply contracts, contact our technical-commercial department to confirm compatibility, lead times and a formal quotation.

Additional information

Battery type

Sealed lead-acid (SLA / VRLA / AGM), maintenance-free

Chemistry

Valve-regulated lead-acid, absorbed electrolyte (AGM)

Nominal voltage

12 V

Capacity

9 Ah (20-hour rate)

Terminals

Faston F1 (0.187 inches / 4.75 mm)

Cell format

NP9-12 (approx. 151 × 65 × 94 mm; total height with terminal ~99 mm)

Approximate weight

2.5 kg

Rechargeable

Yes

Compatibility

Mortara ELI 350 Electrocardiograph

Manufacturer reference

Mortara / Welch Allyn 4800-010 (documented in specialised distribution; not found in GUDID)

Estimated life

3-5 years under nominal conditions

Use

Power supply for diagnostic equipment (ECG) in hospitals, clinics and diagnostic centres

Installation

Direct in the battery compartment, reusing the unit's wiring

Dimensions

151 × 65 × 94 mm (NP9-12 / NPX-35 format)

OEM reference

Mortara Instruments 4800-010 / SERV-ASSY-171-01