Description
1. The reliable power source for your Mortara ELI 250
This 12 V and 2.3 Ah battery is the power replacement indicated for the Mortara ELI 250 electrocardiograph, one of the most common ECG units in cardiology clinics, emergency departments and primary care. Its sealed lead-acid (VRLA/AGM) technology guarantees a stable, leak-free power supply with the autonomy needed to complete successive examinations without relying on the mains. It is a high-performance, maintenance-free and rechargeable replacement that restores the equipment to full operation in minutes.
2. Technical explanation: how this battery works
The battery uses valve-regulated lead-acid (VRLA) chemistry with absorbed glass mat (AGM) electrolyte, making it sealed, rechargeable and suitable for use in portable medical devices. It supplies a nominal voltage of 12 V with a capacity of 2.3 Ah (20-hour rate), sufficient to power the ECG recording, thermal printing and display of the ELI 250 during clinical activity. Its sealed construction allows spill-proof installation, and its compact format (178 × 34 × 60 mm, Faston F1 0.187″ terminals) fits into the equipment’s battery compartment. Like all VRLA cells, it offers a typical design life of 3 to 5 years under nominal use and charge conditions, with excellent recovery after deep discharges.
3. Technical Specifications
| Characteristic | Specification |
| Battery type | Sealed lead-acid (VRLA / AGM), maintenance-free |
| Nominal voltage | 12 V |
| Capacity | 2.3 Ah (20-hour rate) |
| Chemistry | Valve-regulated lead-acid, absorbed electrolyte (AGM) |
| Terminals | Faston F1 (0.187 inches / 4.75 mm) |
| Dimensions (L × W × H) | 178 × 34 × 60 mm (NP2.3-12 cell format) |
| Rechargeable | Yes |
| Compatible equipment | Mortara ELI 250 Electrocardiograph (cell format also documented in the ELI 250c / ELI 150 / ELI 210 family; check compartment) |
| Use | Power supply for diagnostic equipment (ECG) in hospitals, clinics and diagnostic centres |
| Estimated life | 3-5 years under nominal conditions (typical VRLA) |
| Installation | Direct fit in the battery compartment, no adaptations required |
| Reference Cahnos | 88889688 |
4. Equivalences and Cross-References
The cell that powers the Mortara ELI 250 conforms to the standard sealed lead-acid format 12 V / 2.3 Ah with Faston F1 terminals, equivalent to the generic reference cell Yuasa NP2.3-12. The references from other brands listed below belong to the same product category (12 V and 2.3 Ah VRLA battery with F1 terminal) and have been verified against manufacturer datasheets and specialist distribution cross-reference tables; they are classified as comparable by category, not 1:1 interchangeable, and require verification of terminal, dimensions and polarity against the specific equipment before replacement.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| GS Yuasa (Yuasa) | NP series (VRLA cell) | NP2.3-12 / NP2.3-12FR | Comparable by category (not interchangeable 1:1) | Sealed lead-acid cell 12 V / 2.3 Ah with Faston F1 terminals, 178 × 34 × 60 mm. Confirmed in official manufacturer datasheet (FR variant with flame-retardant casing). Same electrical performance; verify F1 terminal of the batch. |
| Raion Power | RG series (medical battery) | RG1223T1 | Comparable by category (not interchangeable 1:1) | 12 V / 2.3 Ah with T1 terminals (Faston 0.187″), documented as compatible with Mortara ELI 250 / ELI 250c electrocardiograph in manufacturer datasheet and authorised distribution. Check terminal orientation. |
| Alpha Source | OEM replacement for Mortara ELI 250 | AS00317 / AS00221 | Comparable by category (not interchangeable 1:1) | Cross-references listed for the Mortara Instruments ELI 250 (12 V / 2.3 Ah SLA) in specialist distribution tables. Confirm terminal version of the order. |
| OSI Batteries | Mortara ELI 250 biomedical battery | B00317 | Comparable by category (not interchangeable 1:1) | Sealed lead-acid battery 12 V / 2.3 Ah for Mortara Instruments ELI 250, confirmed in manufacturer/distributor datasheet. Same dimensions as NP2.3-12 cell. |
| Interstate Batteries | SLA 12 V range | SLA1015 | Comparable by category (not interchangeable 1:1) | 12 V / 2.3 Ah cross-reference included in the ELI 250 compatibility table from specialist distribution. Verify F1 terminal before replacing. |
| MK Battery | Biomedical range | BMED00317 | Comparable by category (not interchangeable 1:1) | Cross-reference documented for the Mortara ELI 250 in distribution tables (12 V / 2.3 Ah). Verify presentation and terminals of the batch. |
There is no equivalence table validated by the equipment manufacturer that authorises third-party batteries; consult with the technical department before use in tenders. Before replacement, each parameter must be verified one by one: voltage (12 V), capacity (2.3 Ah), chemistry (sealed lead-acid VRLA), terminal type (Faston F1 0.187″) and compartment dimensions.
5. Selection tips and variants of interest
Identify the exact model of your equipment: this 12 V / 2.3 Ah battery is the one indicated for the Mortara ELI 250. If your equipment is an ELI 250c, ELI 150 or ELI 210, confirm the compartment with the technical department, as they share the cell format in much of the installed base but this should not be assumed without verification.
Check the terminal: the equipment requires Faston F1 (0.187″) terminals. Do not replace with cells with terminals of another size or with integrated wiring without prior validation.
Prevention and maintenance: VRLA cells self-discharge slowly at rest; if the equipment will remain off for long periods, recharge it periodically to prevent the voltage from dropping below the recovery threshold (≈10.5 V). Replace the battery when the recording autonomy is noticeably reduced or the equipment warns of low battery.
Variants of the same Mortara family on Cahnos: 12 V / 9 Ah battery for ELI 350 (ref. 88881113), 12 V / 7 Ah battery for ELI 380 (ref. 88889604), 12 V / 1.2 Ah battery for ELI 50 (ref. 88889503) and 6 V / 1 Ah battery for ELI 100 (ref. 88888936). Do not interchange these references between models: each equipment accepts a specific voltage and capacity.
For institutional orders, tenders or ongoing supply contracts, please contact our technical-commercial department to confirm compatibility, lead times and a formal quotation.