Description
1. The reliable power source for your Mortara ELI 380
This 12 V and 7 Ah battery is the power supply replacement indicated for the Mortara ELI 380 electrocardiograph, a resting ECG device found in cardiology consultations, emergency departments and occupational medicine. Its sealed lead-acid (VRLA/AGM) technology guarantees a stable and leak-free power supply, with the autonomy needed to complete successive examinations without depending on the mains. It is a high-performance, maintenance-free and rechargeable replacement that restores full operability to the equipment in a few minutes.
2. Technical explanation: how this battery works
The battery uses valve-regulated lead-acid (VRLA) chemistry with absorbed glass mat (AGM) electrolyte, making it leak-proof, rechargeable and suitable for use in portable medical devices. It supplies a nominal voltage of 12 V with a capacity of 7 Ah (20-hour rate), sufficient to power the ECG recording, display and electronics of the ELI 380 during clinical activity. Its sealed construction allows spill-free installation, and its standard NP7-12 cell format (151 × 65 × 97.5 mm) with Faston F1 terminals fits into the equipment’s battery compartment, reusing the original wiring. Like all VRLA cells, it offers a typical design life of 3 to 5 years under nominal use and charge conditions, with excellent recovery after deep discharges.
3. Technical Specifications
| Characteristic | Specification |
| Reference Cahnos (SKU) | 88889604 |
| OEM reference of the equipment it covers | Mortara / Welch Allyn 4800-013 |
| Battery type | Sealed lead-acid (VRLA / AGM), maintenance-free |
| Nominal voltage | 12 V |
| Capacity | 7 Ah (20-hour rate) |
| Chemistry | Valve-regulated lead-acid, absorbed electrolyte (AGM) |
| Terminals | Faston F1 (0.187 inches / 4.75 mm) |
| Dimensions (L × W × H) | 151 × 65 × 97.5 mm (NP7-12 cell format) |
| Approximate weight | 2.04 kg |
| Rechargeable | Yes |
| Compatible equipment | Electrocardiograph Mortara ELI 380 (cell format shared with ELI 280; verify compartment) |
| Use | Power supply for diagnostic equipment (ECG) in hospitals, clinics and diagnostic centres |
| Estimated life | 3-5 years under nominal conditions (typical VRLA) |
| Installation | Direct in the battery compartment, reusing the unit’s wiring |
| Presentation | Unit |
4. Equivalences and Cross-References
The cell that powers the Mortara ELI 380 conforms to the standard sealed lead-acid 12 V / 7 Ah format with Faston F1 terminals, equivalent to the generic reference cell Yuasa NP7-12; the equipment’s OEM reference (4800-013) is confirmed in specialist distribution catalogues and battery manufacturer datasheets. The references from other brands listed below belong to the same product category (12 V and 7 Ah VRLA battery with F1/T1 terminal) and have been cross-checked against manufacturer datasheets and specialist distribution cross-reference tables; they are classified as comparable by category, not 1:1 interchangeable, and require verification of terminal, dimensions and polarity against the specific equipment before replacement.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| GS Yuasa (Yuasa) | NP series (VRLA cell) | NP7-12 / NP7-12FR | Comparable by category (not interchangeable 1:1) | Sealed lead-acid cell 12 V / 7 Ah with Faston F1 terminals, 151 × 65 × 97.5 mm. Confirmed in official manufacturer datasheet (FR variant with flame-retardant casing). Same electrical performance; check F1 terminal of the batch. |
| Power-Sonic | PS Series (AGM) | PS-1270-F1 | Comparable by category (not interchangeable 1:1) | 12 V / 7 Ah with F1 Faston terminal and AGM technology, documented as a replacement for OEM Mortara 4800-013 in ELI 280 / ELI 350 / ELI 380 electrocardiographs in specialist distribution tables. Verify dimensions and polarity. |
| Raion Power | RG series (medical battery) | RG1270T1 | Comparable by category (not interchangeable 1:1) | 12 V / 7 Ah with T1 terminals (Faston 0.187″), documented as compatible with Mortara ELI 280 electrocardiograph in manufacturer datasheet. Same performance; verify terminal orientation and wiring. |
| OSI Batteries | Mortara biomedical battery | B00320 | Comparable by category (not interchangeable 1:1) | Sealed lead-acid battery 12 V / 7 Ah for Mortara Instruments ELI 280 / 4800-013, confirmed in manufacturer/distributor datasheet. Same dimensions as NP7-12 cell. |
| Danlee Medical | 12 V biomedical range | SLA1075 | Comparable by category (not interchangeable 1:1) | Battery comparable to OEM Mortara 4800-013 (12 V SLA AGM); the distributor datasheet declares 8 Ah nominal, so capacity, terminal and dimensions must be verified before replacement. |
There is no equivalence table validated by the equipment manufacturer that authorises third-party batteries; consult the technical department before use in tenders. Before replacement, each parameter must be verified one by one: voltage (12 V), capacity (7 Ah), chemistry (sealed lead-acid VRLA/AGM), terminal type (Faston F1 0.187″) and compartment dimensions (NP7-12 format).
5. Selection tips and variants of interest
Identify the exact model of your equipment: this 12 V / 7 Ah battery is the one indicated for the Mortara ELI 380 and shares the cell format with the ELI 280; always confirm the compartment and terminal before replacement. Do not swap it for cells of a different capacity or with integrated wiring without prior technical validation.
Prevention and maintenance: VRLA cells self-discharge slowly when idle; if the equipment is to remain switched off for long periods, recharge it periodically to prevent the voltage from dropping below the recovery threshold (≈10.5 V). Replace the battery when the recording autonomy is noticeably reduced or the equipment warns of low battery.
Variants of the same Mortara family on Cahnos: 12 V / 9 Ah battery for ELI 350 (ref. 88881113), 12 V / 2.3 Ah battery for ELI 250 (ref. 88889688), 12 V / 1.2 Ah battery for ELI 50 (ref. 88889503) and 6 V / 1 Ah battery for ELI 100 (ref. 88888936). Do not interchange these references between models: each equipment accepts a specific voltage and capacity.
For institutional orders, tenders or continuous supply contracts, contact our technical-commercial department to confirm compatibility, lead times and formalised quotation.