Description
1. Product Presentation
The original Fukuda Denshi battery for the Cardimax FX-2111 electrocardiograph (ref. Cahnos 88888189) is the power replacement designed by the equipment manufacturer to maintain continuous diagnostics even without connection to the mains. With its 9.6 V and 1.7 Ah Ni-MH chemistry, it guarantees the accuracy and stability of electrocardiographic recording in cardiology clinics, emergency departments, health centres and ambulatory diagnostic units. It is the direct replacement pack for the FX-2111 battery compartment, with the connector and dimensions of the official construction, and is supplied with immediate dispatch in 24-72 h and a formal quotation for institutional purchases.
2. Technical explanation of the equipment and the battery
The Fukuda Denshi Cardimax FX-2111 is an interpretive electrocardiograph that operates on mains power (100-240 V AC) or, in portable mode, on direct current through its rechargeable battery pack. The Ni-MH battery (nickel-metal hydride) consists of a set of 8 x 1.2 V cells totalling the nominal 9.6 V, with a capacity of 1.7 Ah and a stored energy of 16.3 Wh, enough to complete 12-lead recording sessions without interruption.
Charging is carried out in an integrated manner: according to the manufacturer’s service documentation, when the power cable is connected to the mains and the equipment remains in standby mode (off), the electrocardiograph itself starts charging the pack automatically, with no need for an external charger. As it is an original brand battery, the mechanical fit in the compartment, the connector and the electrical parameters match the factory specification exactly, avoiding compatibility errors and voltage drops during a recording.
3. Technical Specifications
| Field | Specification |
|---|---|
| Brand / compatible system | Fukuda Denshi — Cardimax FX-2111 electrocardiograph (12-lead ECG); common use documented by authorised distributors in FCP-2155 and FX-2155 (practical market use, not manufacturer specification) |
| Original manufacturer reference | HHR-13F8G1 (official construction; this commercial data sheet transcribes it as HHR-13FBGI) |
| Alternative factory designation | 8-HRAAFD (same pack, confirmed in distribution sources) |
| Reference Cahnos (SKU) | 88888189 |
| Type | Original brand (equipment manufacturer’s construction) |
| Technology | Ni-MH (nickel-metal hydride) — 8-cell rechargeable pack |
| Nominal voltage | 9.6 V |
| Capacity | 1.7 Ah |
| Stored energy | 16.3 Wh |
| Approximate weight | 150 g |
| Pack dimensions | 75 × 45 × 30 mm |
| Recharge | Integrated by the electrocardiograph in standby mode with the mains cable connected |
| Application | Resting electrocardiographic recording, arrhythmia analysis and ambulatory diagnostics |
4. Equivalences and Cross-References
The official reference stamped by the manufacturer on the original pack of the Cardimax FX-2111 is HHR-13F8G1, consistently confirmed in distribution sources and industry catalogues; the alternative factory designation 8-HRAAFD corresponds to the same 9.6 V Ni-MH pack. The reference heading this commercial data sheet appears transcribed as HHR-13FBGI, a transcription that does not literally match the manufacturer’s official construction. There is no cross-reference equivalence table published and validated by Fukuda Denshi against other manufacturers; the third-party reference cited below has been cross-checked in catalogues from its own manufacturers or authorised distributors and is classified as comparable by category, not 1:1 interchangeable, as it differs in capacity, dimensions and originality condition:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Cameron Sino | Replacement battery for Fukuda Denshi FX-2111 / FCP-2155 / FX-2155 | CS-FXD211MD | Comparable by category (not interchangeable 1:1) | Aftermarket Ni-MH replacement of 9.6 V with higher capacity of 2000 mAh (19.2 Wh) and dimensions 115.56 × 50.25 × 14.37 mm (weight ≈ 290 g); replaces HHR-13F8G1 / 8-HRAAFD. Confirmed in authorised distributor catalogues. Check fit, connector and autonomy before replacing. |
There is no equivalence table validated by the manufacturer for this battery against other brands; consult the technical department before using in tenders. Numerous generic 2000 mAh replacements claiming compatibility based on the HHR-13F8G1 / 8-HRAAFD reference are also found on the market; they are not listed because no official technical data sheet from the pack manufacturer itself is available for verification.
5. Selection tips and variants of interest
Check the reference stamped on your battery: before ordering, confirm that the pack removed from the compartment shows the reference HHR-13F8G1 or the designation 8-HRAAFD. If your equipment works with a different pack, do not force the replacement: Fukuda electrocardiographs from the same manufacturer use different constructions depending on the model.
Do not mix families: this datasheet corresponds exclusively to the 1.7 Ah construction of the Cardimax FX-2111. At Cahnos you will find variants of the same brand for other equipment: Ni-MH 9.6 V / 1.7 Ah battery for Cardimax FX-7202 / FX-2201 / FX-7201 (ref. 88888192), original Ni-MH 9.6 V / 4 Ah battery for FCP-7101 / FX-7102 (ref. 88888905) and its compatible version (ref. 88888612), and Ni-MH 9.6 V / 3.8 Ah battery for Cardimax FX-7402 (ref. 88889321).
Ni-MH pack maintenance: to preserve capacity, carry out full charge cycles in standby and avoid prolonged deep discharges; if the equipment is to remain unused for several weeks, leave the battery charged and check the level periodically. If the battery life is markedly reduced or the equipment warns of low battery after a recent charge, replace the pack so as not to interrupt the examination.
For institutional orders, tenders or ongoing supply contracts, contact our technical-commercial department to confirm the exact reference, compatibility and formal quotation.