Description
1. Product Presentation
The original Fukuda Denshi battery for the Cardimax FX-7402 electrocardiograph (ref. Cahnos 88889321) is the power replacement designed by the equipment manufacturer to maintain continuous diagnostics even without connection to the mains. With its Ni-MH chemistry of 9.6 V and 3.8 Ah, it guarantees the accuracy and stability of electrocardiographic recording in cardiology clinics, emergency departments, health centres and ambulatory diagnostic units. It is the direct replacement pack for the FX-7402 battery compartment, with the connector and dimensions of the official construction, and is supplied with immediate dispatch 24-72 h and a formalised quotation for institutional purchases.
2. Technical explanation of the equipment and the battery
The Fukuda Denshi Cardimax FX-7402 is an interpretive 12-lead electrocardiograph with touchscreen that works with mains power (universal 100-240 V AC, 50/60 Hz) or, in portable mode, with direct current through its rechargeable battery pack of 9.6 V DC. The Ni-MH (nickel-metal hydride) battery is a smart battery made up of a set of 8 cells of 1.2 V that add up to the nominal 9.6 V, with a capacity of 3.8 Ah and a stored energy of 36.48 Wh, sufficient to complete electrocardiographic recording sessions without interruptions.
Charging is carried out in an integrated manner: according to the service documentation of the CardiMax family, when the power cable is connected to the mains and the equipment remains in standby mode (off), the electrocardiograph itself automatically starts charging the pack, without the need for an external charger. As it is an original battery of the brand, the mechanical fit to the compartment, the connector and the electrical parameters match the factory specification, avoiding compatibility errors and voltage drops during full examination.
3. Technical Specifications
| Field | Specification |
| Brand / compatible system | Fukuda Denshi — Cardimax FX-7402 electrocardiograph (12-lead ECG); common use documented by distributors in FX-7412, FX-7432, FCP-7311, FCP-7401, FCP-7411, FCP-7431/FCP-7431S, ECP-7600, ECP-7631 and ECP-7641 (practical market use, not official manufacturer specification) |
| Original manufacturer reference | 8/HRY-4/3AFD (according to the official specification sheet of the FX-7402: smart battery, Ni-MH; this commercial data sheet transcribes it as HRY-4/3AFD) |
| Reference Cahnos (SKU) | 88889321 |
| Type | Original brand (equipment manufacturer’s construction) |
| Technology | Ni-MH (nickel-metal hydride) — rechargeable pack of 8 cells of 1.2 V (smart battery) |
| Nominal voltage | 9.6 V |
| Capacity | 3.8 Ah (3800 mAh) |
| Stored energy | 36.48 Wh |
| Equipment power supply | 100-240 V AC (mains) or 9.6 V DC (rechargeable battery pack) |
| Approximate dimensions of the pack | ≈ 137 × 68 × 18-20 mm depending on documented replacement cells; verify compartment dimension |
| Approximate weight | ≈ 430-570 g depending on source |
| Recharge | Integrated by the electrocardiograph in standby mode with the mains cable connected |
| Application | Resting electrocardiographic recording, arrhythmia analysis and ambulatory diagnostics |
4. Equivalences and Cross-References
The official reference stamped by the manufacturer on the original pack of the Cardimax FX-7402 is 8/HRY-4/3AFD, confirmed in the specifications of Fukuda Denshi itself (FX-7402 data sheet) and consistently in specialised distribution catalogues; the data sheet heading this commercial listing transcribes it as HRY-4/3AFD, a common transcription in the market for the same Ni-MH pack of 9.6 V and 3.8 Ah. The extended compatibility with other families (FX-7412, FX-7432, FCP-7311, FCP-7401, FCP-7411, FCP-7431/S, ECP-7600, ECP-7631, ECP-7641) is documented by replacement battery distributors, not in the official specification of the equipment manufacturer. There is no published and validated cross-reference table by Fukuda Denshi against other manufacturers; the third-party reference cited below has been verified in catalogues of authorised distributors of its own brand and is classified as comparable by category, not interchangeable 1:1, as it differs in dimensions, weight and originality condition:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Cameron Sino | Replacement battery for Fukuda FX-7402 / Cardimax FX-7402 / FCP-7311 / FCP-7401 / FCP-7411 | CS-FXD740MD | Comparable by category (not interchangeable 1:1) | Aftermarket Ni-MH replacement of 9.6 V and 3800 mAh (36.48 Wh) with dimensions 137.13 × 67.90 × 17.40 mm and weight ≈ 510 g; replaces 8/HRY-4/3AFD. Confirmed in catalogues of authorised distributors of the brand. Verify fit, connector and autonomy before replacing. |
There is no equivalence table validated by the manufacturer for this battery against other brands; consult the technical department before using in tenders. In the market there are also numerous generic replacements of 3800 mAh (9.6 V, Ni-MH) that declare compatibility based on the reference 8/HRY-4/3AFD; they are not listed because there is no verified official technical data sheet from the pack manufacturer itself.
5. Selection tips and variants of interest
Check the reference stamped on your battery: before ordering, confirm that the pack removed from the compartment shows the reference 8/HRY-4/3AFD (or the transcription HRY-4/3AFD). If your equipment works with a different pack, do not force the replacement: Fukuda electrocardiographs from the same manufacturer use different constructions depending on the model.
Do not mix families: this datasheet corresponds exclusively to the 3.8 Ah construction of the Cardimax FX-7402. In Cahnos you will find the variants of the same brand for other equipment: Ni-MH 9.6 V / 1.7 Ah battery for Cardimax FX-7202 / FX-2201 / FX-7201 (ref. 88888192), Ni-MH 9.6 V / 1.7 Ah battery for Cardimax FX-2111 (ref. 88888189) and Ni-MH 9.6 V / 4 Ah battery for FCP-7101 / FX-7102 in original version (ref. 88888905) and compatible version (ref. 88888612).
Ni-MH pack maintenance: to preserve capacity, perform full charge cycles in standby and avoid prolonged deep discharges; if the equipment is to remain unused for several weeks, leave the battery charged and check the level periodically. If battery life drops markedly or the equipment warns of low battery after a recent charge, replace the pack so as not to interrupt the examination.
For institutional orders, tenders or ongoing supply contracts, contact our technical-commercial department to confirm the exact reference, compatibility and formal quotation.