Original GE Healthcare Battery 30344270 (303-442-70) · Ni-Cd 18 V 1.8 Ah for Cardiosmart MAC 1200 Electrocardiograph (MAC 1000/1100/1200ST) · Ref. Cahnos 88888911

200,00 €

Original GE Healthcare battery ref. 30344270 for Cardiosmart MAC 1200 electrocardiograph (Hellige / Marquette family). Rechargeable medical electronics replacement in nickel-cadmium (Ni-Cd) chemistry, nominal voltage 18 V and capacity 1.8 Ah (≈32.4 Wh), with assembly that reproduces the equipment manufacturer’s specifications. Direct replacement in the compartment without tools, indicated for cardiology services, ECG clinics and preventive maintenance programmes that require original parts. Replacement management in accordance with WEEE regulations. Available at Cahnos with technical advice and fast shipping; request a quotation for institutional orders and tenders.

International shipping. Import duties and taxes are payable by the recipient.

Reference
0159033

Description

1. Commercial Introduction

At Cahnos we make available to you the original GE Healthcare battery ref. 30344270 for the electrocardiograph Cardiosmart MAC 1200, a genuine part from the equipment manufacturer (Hellige / Marquette family, now GE Healthcare). It is the replacement part that keeps your electrocardiograph operational when working in battery mode: resting ECG recording, stress testing and monitoring without depending on the mains electricity supply. Available with technical advice and fast delivery for cardiology departments, ECG clinics, internal medicine units and medical electronics maintenance programmes, with replacement management in accordance with the WEEE regulations.

2. Technical explanation of the equipment

The electrocardiographs of the Cardiosmart / MAC family (GE Healthcare, formerly Hellige and Marquette lines) incorporate two independent power supply systems: the main rechargeable battery, which powers the equipment in portable use, and a small button-type backup battery that preserves the date, time and clinical configuration during shutdown or replacement of the main battery.

This battery supplies a nominal voltage of 18 V and a capacity of 1.8 Ah (≈32.4 Wh), enough energy to maintain the electrocardiographic recording, the display and the thermal recorder during scheduled examinations. The original reference 30344270 is documented by GE HealthCare as an 18 V nickel-cadmium (Ni-Cd) battery. The pack is housed in the specific compartment of the equipment and its replacement is carried out without specialised tools.

Verification note: the official GE HealthCare documentation identifies the original part 30344270 as an 18 V Ni-Cd battery; some historical distribution data sheets have cited it as Ni-MH. We recommend verifying the batch label of the received item and confirming with the technical service before installation.

3. Technical Specifications

Data cross-checked against the product data sheet and the official GE HealthCare parts catalogue (GE HealthCare Service Shop) for reference 30344270.

Parameter Specification
Reference Cahnos (SKU) 0159033 / 88888911
Original manufacturer reference GE 30344270 (also 303-442-70)
Official GE equivalent B9902022 (cited in GE HealthCare One Self)
Equipment manufacturer GE Healthcare (Cardiosmart; Hellige / Marquette family)
Type Brand original
Application Electrocardiograph GE Healthcare Cardiosmart MAC 1200
Technology Ni-Cd (nickel-cadmium) according to official GE documentation; verify the batch label
Nominal voltage 18 V
Capacity 1.8 Ah (1800 mAh)
Energy 32.4 Wh
Weight Approximately 200 g
Dimensions 85 x 60 x 35 mm (data sheet value; the authorised distribution documents ≈215 x 68 x 23 mm; verify with the battery removed)
Use Rechargeable; periodic replacement in preventive maintenance
Recycling Management in accordance with WEEE regulations

Documented compatibility of the original reference 30344270 (GE HealthCare Service Shop parts catalogue): CardioSmart, MAC 1100, MAC 1200 WU_0332 and MAC 1200ST. The authorised distribution extends compatibility to MAC 1000; always verify the model label of the equipment.

4. Equivalences and Cross-References

Note on the code: reference 30344270 is the original part of the equipment, verified in the official GE HealthCare parts catalogue (GE HealthCare Service Shop), where it appears as an 18 V nickel-cadmium battery for diagnostic ECG. GE HealthCare indicates as the official equivalent article reference B9902022, defined as a replacement for 30344270 in the GE HealthCare One Self catalogue. There is no equivalence table validated by GE Healthcare that cross-references this part with third-party manufacturers under 1:1 replacement conditions; the following cross-references have been checked against battery manufacturer and authorised distribution catalogues, but must be validated field by field (chemistry, voltage, capacity, dimensions and connector).

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
GE Healthcare Battery ECG Cardiosmart (official GE equivalent, GE HealthCare One Self catalogue) B9902022 Comparable by category (not interchangeable 1:1) Cited by GE HealthCare as a replacement for 30344270; 18 V Ni-Cd with a declared capacity of 1.3 Ah. Validate availability, chemistry and batch label before ordering.
Cameron Sino Replacement battery for CardioSmart / MAC 1000-1200, MAC 1200ST and Hellige Cardio Smart ES500 CS-GME100MD Comparable by category (not interchangeable 1:1) 18 V, 2000 mAh (≈36 Wh), Ni-MH chemistry and dimensions 215 x 68 x 23 mm; replaces 30344270 / 303-442-70. Slightly higher capacity; confirm charging electronics, connector and fit.
R&D Batteries Replacement battery for GE Healthcare Mac 1000 / 1100 / 1200 Cardio Smart 5877 Comparable by category (not interchangeable 1:1) 18 V Ni-Cd of 1.8 Ah documented as a replacement for the 30344270; same chemistry and nominal capacity as the original part. Third-party construction; verify connector and dimensions.
Davis Medical Electronics Battery GE / Marquette Mac 1200 (ECG) RDS-EKG-5877 Comparable by category (not interchangeable 1:1) 18 V, 1.8 Ah, Ni-Cd, OEM compatibility with GE MAC 1200 ECG. Third-party replacement; verify connector and compartment fit.

There is no equivalence table validated by the equipment manufacturer (GE Healthcare) that cross-references this part with third parties; the cross-references indicated have been verified against the official GE HealthCare parts catalogue and against authorised distribution sources (Cameron Sino, R&D Batteries, Davis Medical Electronics, among others), but the 1:1 replacement must be validated field by field before use in tenders. Consult the technical department before use in tenders.

5. Selection tips and variants of interest

  • Verify the exact model of the equipment: this battery is the one indicated for the Cardiosmart MAC 1200; the original reference 30344270 is also documented for Cardiosmart, MAC 1100, MAC 1200 WU_0332 and MAC 1200ST (official GE HealthCare source) and distribution extends it to MAC 1000.
  • Check the chemistry: the original GE part 30344270 is Ni-Cd 18 V. If your maintenance plan allows a more economical alternative, Cahnos offers a compatible version in Ni-MH chemistry with the same voltage and housing (ref. 88888210); validate the charging compatibility with the technical service before fitting.
  • Do not confuse it with the backup battery: the Cardiosmart MAC 1200 also uses a BR2330FH button cell of 3 V with 2 tabs for clock and memory (ref. Cahnos 88888227), which does not replace the main battery nor vice versa.
  • Nor with other batteries in the MAC family: the MAC 5000 / Mac Pac uses 18 V Ni-MH of 3.5 Ah (ref. Cahnos 88888228) and the Mac PC 19.2 V (ref. Cahnos 88888221), with different capacity and housing.
  • Size the spare part: compare the dimensions with the removed battery; the datasheet indicates 85 x 60 x 35 mm while the authorised distribution documents ≈215 x 68 x 23 mm for this reference.
  • After installation: perform a full charge cycle before putting the equipment into service and check the battery indicator of the electrocardiograph.
  • Environmental management: deliver the exhausted battery to a specialised collection point (WEEE); do not dispose of it in the general waste container.
  • For institutional orders, tenders or continuous supply contracts, contact our technical-commercial department to confirm compatibility, exact reference and formalised quotation.

Additional information

Manufacturer reference

GE 30344270 (also 303-442-70)

Official GE equivalent

B9902022 (18 V Ni-Cd, 1.3 Ah according to GE HealthCare One Self)

Product type

Original rechargeable battery for electrocardiograph

Technology

Ni-Cd (nickel-cadmium) according to official GE documentation; verify the batch label

Nominal voltage

18 V

Capacity

1.8 Ah (1800 mAh)

Energy

32.4 Wh

Approximate weight

Approximately 200 g

Dimensions

85 x 60 x 35 mm (data sheet value; authorised distribution ≈215 x 68 x 23 mm; verify with battery removed)

Compatibility

GE Healthcare Cardiosmart MAC 1200; documented for Cardiosmart, MAC 1100, MAC 1200 WU_0332 and MAC 1200ST; distribution extends it to MAC 1000

Use

Rechargeable; portable power supply for the electrocardiograph in cardiology, ECG clinics and maintenance

Rechargeable

Yes; recharges with the equipment connected to the mains

Installation

Direct replacement in the equipment compartment, without tools

Recycling

Management in accordance with WEEE regulations

Application

Portable power supply for the electrocardiograph; cardiology, ECG clinics and preventive maintenance

Presentacion

Unit

Reviews

There are no reviews yet.

Be the first to review “Original GE Healthcare Battery 30344270 (303-442-70) · Ni-Cd 18 V 1.8 Ah for Cardiosmart MAC 1200 Electrocardiograph (MAC 1000/1100/1200ST) · Ref. Cahnos 88888911”

Your email address will not be published. Required fields are marked *