Description
1. Introduction
Keep your Cardioline Cardiette AR600 electrocardiograph (and its AR600 ADV variant) operational with the replacement battery of original reference MFR BATT/110236, supplied under the Cahnos reference 88888090. This rechargeable 9.6 V, 1.7 Ah pack is the power component that ensures the device’s continuity of care during resting ECG recordings, emergencies and primary care, allowing successive electrocardiograms to be completed without mains connection. An essential spare part for cardiology departments, clinics, diagnostic centres and fleets of portable equipment, available with immediate dispatch and special terms for institutional purchases, maintenance contracts and tenders.
2. Technical Explanation
The portable electrocardiographs of the Cardiette AR600 / AR600 ADV series (Cardiette family from Cardioline, Elettronica Trentina group) are powered by an internal rechargeable battery with a nominal voltage of 9.6 V and a capacity of 1.7 Ah (1700 mAh), sufficient to support the acquisition of the ECG recording, signal processing and thermal printing of the trace during clinical activity. The usual chemistry of this platform is Ni-MH (nickel-metal hydride), a rechargeable technology that offers good voltage stability during discharge and a low memory effect; the configuration of 8 cells of 1.2 V in series gives the nominal 9.6 V, a figure that must always be confirmed on the batch label.
Replacement is carried out by removing the depleted battery from the device compartment and installing the new one respecting the orientation of the specific Cardiette connector (positive terminal facing forward, with a locking tab that seats against the wall of the housing), without the need for tools or adaptations. After installation, it is recommended to allow the device to complete its startup self-test without interruptions and to perform a full charge and discharge cycle before clinical use so that the battery management system (BMS) correctly recognises the new pack.
3. Technical Specifications
| Field | Specification |
| Application | Electrocardiograph (ECG machine) Cardioline Cardiette AR600 / AR600 ADV (Cardiette family) |
| Original manufacturer reference | BATT/110236 (MFR); associated alternative code: 120236 |
| Reference Cahnos (SKU) | 88888090 |
| Nominal voltage | 9.6 V |
| Nominal capacity | 1.7 Ah (1700 mAh) |
| Estimated nominal energy* | ≈ 16.3 Wh (9.6 V × 1.7 Ah) |
| Type / chemistry* | Rechargeable Ni-MH battery (nickel-metal hydride); verify batch label |
| Cell configuration* | 8 cells of 1.2 V in series (up to 9.6 V nominal); verify batch label |
| Reference dimensions of the pack** | ≈ 57.96 × 51.46 × 29.38 mm (compatible spare parts verified in specialised distribution) |
| Rechargeable | Yes |
| Installation | Direct replacement in the battery compartment (Cardiette-specific connector) |
| Presentation | Unit |
*Data estimated from the family platform and compatible spare parts verified in specialised distribution; they must be checked on the batch label and against the device compartment before purchase. The main specifications (9.6 V, 1.7 Ah, reference BATT/110236) come from the official datasheet of the line. **Dimensions declared in public datasheets of replacement battery manufacturers (Cameron Sino / CS, 2500 mAh), not from the device manufacturer.
4. Equivalences and Cross-References
The original reference BATT/110236 (Cardioline, Cardiette AR600 series) has been cross-checked against specialised distribution catalogues and battery replacement manufacturers. The code 120236 appears consistently in multiple independent sources as the alternative OEM construction of the same pack. There is no official equivalence table published by the device manufacturer cross-referencing BATT/110236 with other brands; the following references share the electrical specifications (9.6 V, Ni-MH chemistry, AR600 platform connector) and have been verified in public datasheets of their respective suppliers and battery manufacturers, so they are classified as comparable by category, not 1:1 interchangeable, and must be validated with the technical department before use in tenders.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| BatteryWeb / Battery Specialists (spare part, USA) | Compatible battery Cardiette AR600 / ECG Recorder AR600ADV — replaces OEM 120236 and BATT/110236 | BW-CS-CAG600MD | Comparable by category (not interchangeable 1:1) | 9.6 V, 2500 mAh (24 Wh), Ni-MH; dimensions 57.96 × 51.46 × 29.38 mm and gross weight ≈ 307 g declared in the supplier’s datasheet; compatibility declared with AR600 and AR600ADV (same 9.6 V platform and same connector); higher capacity than the original reference (2.5 Ah vs 1.7 Ah). Confirmed in the supplier’s datasheet. |
| CS (spare part manufacturer) / Batteries America | Spare part for Colson ECG Cardiette AR600 — replaces Cardiette 120236 and BATT/110236 | CS-CAG600MD | Comparable by category (not interchangeable 1:1) | Same electrical specifications (9.6 V, Ni-MH, 2500 mAh); MPN confirmed in the replacement manufacturer’s datasheet and at an authorised distributor; dimensions 57.96 × 51.46 × 29.38 mm. Capacity higher than the original; connector and BMS declared compatible with AR600 / AR600ADV. |
| Energystox (spare part, USA) | Replacement for Cardiette AR600 E.C.G. / ECG Recorder AR600ADV (120236 / BATT/110236) | EX-L346 | Comparable by category (not interchangeable 1:1) | 9.6 V, 2500 mAh, Ni-MH; supplier’s own reference associated with the same OEMs (120236 / BATT/110236), confirmed in its public datasheet; dimensions and connector pending verification against the device manufacturer’s primary source. |
There is no equivalence table validated by the manufacturer (Cardioline / Elettronica Trentina); consult the technical department before use in tenders. The market also offers numerous third-party spare parts sold under marketplace codes (e.g. TollCor, ZEEKAY, NEENO, FBNPIUT) without a manufacturer code verified in a primary source: their use as a substitute requires prior verification (not verified).
5. Selection tips and variants of interest
Identify the exact model of your device: the reference BATT/110236 (120236) corresponds to the Cardiette AR600 and AR600 ADV series; confirm the part number shown on the depleted battery label before placing the order. Do not use it in other series of the family (AR1200, Delta, Elan) that use different voltages and connectors.
Verify chemistry and connector: the platform uses rechargeable Ni-MH packs of 9.6 V with a specific Cardiette connector; do not replace with lead-acid cells or packs with a different connector without prior validation.
First charge cycle: after installing the new battery, allow the device to complete the startup self-test without interruptions and perform a full charge and discharge cycle so that the BMS adjusts its thresholds and avoids false low-battery warnings during the first clinical use.
Storage: Ni-MH batteries self-discharge at rest (1–2 % daily); if the device remains off for long periods, recharge it periodically and avoid the voltage dropping below the pack’s recovery threshold (typically 8.0–8.4 V in 9.6 V packs). At the end of its service life, dispose of the battery at a WEEE collection point; never incinerate it.
Variants of the same family in Cahnos: for the Cardiette AR1200 / AR1200 ADV we have the MFR 120176 12 V battery (ref. 88888089); for the Delta 60+ series the MFR 110260 24 V (ref. 88888778); for Delta 1+/3 the MFR 1220211-01 (ref. 88888069) and for Cardiette Elan the MFR 110260 12 V and 2.7 Ah (ref. 888881326). Do not interchange these references between models: each unit accepts a specific voltage, capacity and connector. For institutional orders, consortia or maintenance contracts, contact our technical-commercial team at Cahnos to confirm exact compatibility and obtain a formal quotation under B2B volume conditions.





Reviews