Description
1. Replacement battery for the Bionet CardioCare 2000 electrocardiograph
The Bionet CardioCare 2000 battery with original reference GPHC 132MOT (SKU Cahnos 88888889) is the ideal replacement to keep the Bionet CardioCare 2000 electrocardiograph operational in demanding medical environments. It is a rechargeable nickel-metal hydride (Ni-MH) pack of 12 V and 3.4 Ah that directly replaces the equipment’s original accumulator, guaranteeing the energy needed for the acquisition, recording and printing of electrocardiographic traces with total reliability.
Manufactured with quality cells and fitted to the original compartment, this battery is the practical solution for hospitals, clinics, health centres and medical transport units that need to keep their fleet of electrocardiographs in continuous operation, reducing downtime and maintenance costs compared to purchasing new equipment.
2. Technical function of the battery in the CardioCare 2000
The Bionet CardioCare 2000 electrocardiograph is a diagnostic cardiology device that records the electrical activity of the heart. During use it requires a stable power supply without voltage drops, as any fluctuation can cause artefacts in the trace or interruptions in the recording. The Ni-MH battery provides the nominal 12 V voltage required by the acquisition circuit and the thermal printer, allowing full autonomy when the device is not connected to the mains.
Ni-MH chemistry offers reliable performance and reduced memory effect, withstanding repeated charge and discharge cycles. When the device’s autonomy decreases noticeably or the system shows a low battery warning, replacing it with this reference restores the device’s original performance. Installation is direct: the battery sits in the original compartment and connects via its pins, without the need for adapters, wiring or modifications.
3. Technical Specifications
| Parameter | Value |
|---|---|
| Application | Electrocardiograph Bionet CardioCare 2000 |
| Original manufacturer reference | GPHC 132MOT (GPHC132MOT) |
| Technology | Ni-MH (nickel-metal hydride) rechargeable |
| Nominal voltage | 12 V |
| Capacity | 3.4 Ah |
| Energy | 40.8 Wh |
| Dimensions | 70 x 85 x 30 mm |
| Weight | Approximately 0.45 kg |
| Connection | Pin connection, direct installation in the original compartment |
| Device manufacturer | Bionet |
4. Equivalences and Cross-References
The reference GPHC 132MOT is not indexed in the GUDID regulatory database (search performed with no results), so no official cross-reference table published by Bionet has been found. Below is the alternative designation of the same pack, found repeatedly and consistently across multiple independent distributors in the sector; this information must be confirmed with the manufacturer before use in tenders or replacement.
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
|---|---|---|---|---|
| Bionet | CardioCare 2000 (same pack as the device) | GP130AAM20YMXZ / 130AAM20YMXZ | Not verified | Alternative designation of the 12 V Ni-MH pack consistently published by several independent distributors (batteryweb, battery-mall, medten, ultragreenbattery); not found in Bionet’s official catalogue or in GUDID; confirm the physical label of the battery before ordering. |
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. At family level, the same reference GPHC132MOT is documented in distribution sources for other equipment from the same brand (EKG3000, CardioTouch 3000 and Cardio 7), but each device must be verified individually (compartment, connector and polarity) before any replacement, as this cross-compatibility has not been officially confirmed.
5. Selection tips and variants of interest
- Verify the device model: confirm on the device plate that it is a Bionet CardioCare 2000 and that the compartment accepts a 12 V Ni-MH pack with pin connection.
- Check the reference engraved on the original battery: if the label shows GPHC132MOT, GP130AAM20YMXZ or 130AAM20YMXZ, this spare part is the right one; if in doubt, contact our technical department.
- Care and maintenance: perform full charge cycles periodically; avoid storing the battery fully discharged or at extreme temperatures to prolong its service life.
- Range variants: if your device belongs to another ECG family (e.g., Cardiette, Delta or series 3500/3600 from the same commercial line), consult Cahnos for the specific batteries for each model, as voltages and capacities differ (9.6 V, 12 V or 24 V depending on the device) and are not interchangeable.
For corporate orders, fleet maintenance or preparation of tenders, our technical-commercial team is at your disposal to confirm exact compatibility with your electrocardiograph before finalising the purchase.