Description
1. Commercial Introduction
The HYLB-722 Li-ion battery, 14.4 V and 2.6 Ah is the natural replacement for the original battery of the Edan 6010 electrocardiographs. Designed for medical electronics services, cardiology clinics and preventive maintenance programmes for portable ECG fleets, it ensures your equipment is always operational during examinations, patient transfers and mains power cuts. Direct installation in the battery compartment, without tools or adaptations: remove the depleted battery and insert this unit.
2. Technical Explanation
The Edan 6010 electrocardiograph is a portable cardiac recording device that, to operate without depending on the mains power supply, incorporates an internal rechargeable lithium-ion (Li-ion) battery. This chemistry offers a high energy density in a lightweight, compact format, with no memory effect, and a stable discharge curve that maintains equipment performance until the end of the charge.
This battery delivers a nominal voltage of 14.4 V with a capacity of 2.6 Ah (2,600 mAh), representing a total energy of 37.44 Wh. It recharges automatically while the electrocardiograph remains connected to its charger or to the mains. When battery life is noticeably reduced or the equipment warns of low battery after only a few hours of charge, it is time to replace the battery.
Reference HYLB-722 corresponds to the original battery for this ECG platform and, according to third-party technical catalogues, is shared by the ECG-6010 and ECG-6020 models of the same family.
3. Technical Specifications
| Reference Cahnos (SKU) | 88890216 |
| Original equipment reference (OEM) | HYLB-722 |
| Application | Edan 6010 electrocardiograph (ECG-6010 / ECG-6020 platform documented in third-party catalogues) |
| Technology | Li-ion (lithium-ion), rechargeable |
| Nominal voltage | 14.4 V |
| Capacity | 2.6 Ah (2,600 mAh) |
| Energy | 37.44 Wh |
| Dimensions | 90 x 70 x 20 mm |
| Weight | Approximately 0.2 kg |
| Device manufacturer | Edan |
| Installation | Direct replacement in the equipment compartment, without tools |
| Recharge | Automatic, integrated in the equipment when connected to the mains |
| Presentation | 1 unit |
4. Equivalences and Cross-References
The original factory battery reference for the Edan 6010 electrocardiograph is HYLB-722, a code consistently documented in industry catalogues and specialised medical battery distribution. The equipment manufacturer does not publish an official cross-reference table with third-party batteries; the alternative indicated below belongs to this same product category, has been cross-checked against manufacturer and authorised distribution catalogues and is classified as comparable by category, not 1:1 interchangeable: before replacement it must be validated field by field (voltage, chemistry, capacity, dimensions and connector).
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Cameron Sino | Medical battery for ECG-6010 / ECG-6020 / iE6 | CS-ECG602MD / MED-CS-ECG602MD | Comparable by category (not interchangeable 1:1) | Li-ion 14.8 V / 3,400 mAh (50.32 Wh), dimensions 73.2 x 70.0 x 18.4 mm; documented replacement for the HYLB-722. Nominal voltage (14.8 V vs 14.4 V) and capacity (3,400 vs 2,600 mAh) differ; verify connector and charging protocol before replacing. Verified in multiple authorised distribution catalogues. |
There is no equivalence table validated by the equipment manufacturer that authorises third-party batteries for reference HYLB-722; the references indicated have been cross-checked against battery manufacturer datasheets and authorised distribution catalogues, but replacement must be validated field by field (voltage, chemistry, capacity, dimensions and connector) before use in tenders. Consult the technical department before using this reference in public procurement.
5. Selection tips and variants of interest
- Confirm the exact model of your equipment: this battery is the one indicated for the Edan 6010 electrocardiograph. Also check the label of the installed battery: the original reference is HYLB-722.
- Voltage group: in the replacement market, the 14.4 V and 14.8 V variants are considered to be in the same voltage group for this platform, but compatibility of the connector and battery management system (BMS) with the equipment must be confirmed before replacing.
- Li-ion maintenance: to extend service life, avoid regular deep discharges and do not expose the battery to extreme temperatures; replace the battery when battery life is noticeably reduced.
- Always order by reference: quote code 88890216 or the equipment’s original reference (HYLB-722) to avoid confusion with other batteries in the Edan family, such as the HYLB-727 for the SE-601 (14.8 V / 5.2 Ah).
- Institutional orders: our catalogue of electrocardiograph batteries includes spare parts for the Edan families and other brands; for tenders or continuous supply contracts, contact our technical-commercial department to confirm compatibility and a formal quotation.





Reviews