Description
1. Reliable power for your Biocare electrocardiograph
The battery for the Biocare ECG-1215 MFR electrocardiograph (ref. Cahnos 88889366) is the power supply spare part indicated for the portable Biocare ECG-1215 electrocardiograph, replacing the original reference HYLB-952. Designed for cardiology departments, clinics and primary care, it allows complete cardiac examinations to be performed without depending on a mains socket, keeping the equipment operational during transfers, emergencies and clinical situations where continuity of recording is critical. It is a rechargeable lithium-ion cell, ready to install and compatible with the device’s original charger.
2. How this battery works
The Biocare ECG-1215 electrocardiograph is a portable electrocardiographic recording device that integrates signal acquisition, screen and internal storage. This 14.8 V, 2.6 Ah (38.48 Wh) battery powers the acquisition module, the screen and the recording electronics during off-grid working sessions. Its lithium-ion chemistry provides a stable discharge curve: the voltage remains practically constant until the end, avoiding sudden cut-offs in the middle of an examination and protecting the integrity of stored traces. The positive-locking connector fits directly into the equipment compartment, without the need for adapters or wiring modifications, and the internal management system (BMS) monitors the charge and discharge of the cell, adding an extra layer of safety to the whole.
3. Technical Specifications
| Application | Electrocardiographs Biocare ECG-1215 |
| Original reference | HYLB-952 |
| Battery type | Lithium-ion (Li-ion), rechargeable |
| Nominal voltage | 14.8 V |
| Capacity | 2.6 Ah (2600 mAh) |
| Energy | 38.48 Wh |
| Weight | Approximately 0.35 kg |
| Dimensions | 60 x 70 x 35 mm |
| Device manufacturer | Biocare |
| Presentation | Unit |
Note: the voltage, capacity and energy indicated correspond to the declared specification for reference HYLB-952. Always verify the compartment and connector of your unit before replacement.
4. Equivalences and Cross-References
There is no equivalence table validated by the manufacturer Biocare that authorises third-party batteries for the ECG-1215. The references listed below come from replacement battery manufacturers that declare they replace reference HYLB-952; they are classified as comparable by category (not 1:1 interchangeable), so before replacing, each one must be verified individually: voltage (14.8 V), capacity, chemistry (Li-ion), connector and compartment dimensions.
| Manufacturer / Brand | Family / Model | Code / Reference | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Cameron Sino | Medical Series (Biocare) | CS-ECG215MD / MED-CS-ECG215MD | Comparable by category (not interchangeable 1:1) | Li-ion 14.8 V / 2600 mAh (38.48 Wh). Declared as a direct replacement for HYLB-952 for the ECG-1215 in multiple specialised distribution datasheets; declared dimensions 132.20 x 37.70 x 19.70 mm, different from those in this datasheet: verify connector and orientation in the compartment before replacement. |
| Kingsener | Medical series (Biocare) | HYLB-952 (compatible ECG-1215) | Comparable by category (not interchangeable 1:1) | Li-ion 14.8 V / 2600 mAh (38.48 Wh), 100% new condition with 1 year declared warranty. Replaces HYLB-952 for the ECG-1215 model; confirm pack dimensions and compatibility with the equipment’s original charger. |
Within the device manufacturer itself, the Biocare ECG-1200 / ECG-1201 / ECG-1210 equipment family uses electrically equivalent packs (14.8 V / 2.6 Ah / 38.48 Wh) under references HYLB-293 and HYLB-683, according to distribution sources; official Biocare data must be confirmed before use and physical interchangeability between models must not be assumed without validating the compartment and connector. Likewise, some replacement manufacturers (AolsteCell, Cowon and others) declare HYLB-952 compatibility with the ECG-1210, ECG-1220 and ECG-1260 models; these compatibility extensions come from third-party catalogues and are not validated by Biocare.
There is no equivalence table validated by the manufacturer that authorises third-party batteries; consult the technical department before use in tenders. Before any replacement with other brands’ spare parts, voltage, capacity, chemistry, connector and dimensions must be checked against the specific unit.
5. Selection tips and variants of interest
Identify the exact model: this battery corresponds to the Biocare ECG-1215 electrocardiograph. Do not swap it for batteries from other models of the same brand without technical validation: each device is fitted with a cell with specific voltage, capacity and dimensions. Also check the label of the installed battery: the original reference is HYLB-952.
Battery care: keep the cell charged if the equipment is to remain idle for long periods and replace the battery when the autonomy is noticeably reduced or the equipment indicates low battery. Use only the electrocardiograph’s original charger to respect the Li-ion charging parameters and avoid habitual deep discharges.
Variants of the same Biocare family at Cahnos: battery for Biocare ECG-1200 MFR HYLB-293 (ref. 88881242, same electrical characteristics 14.8 V / 2.6 Ah), battery for Biocare ECG-9803 MFR HYLB-114A (ref. 88889365) and battery for Biocare ECG-3010 MFR HYLB-947 (ref. 88889367). Do not interchange these references between models: each electrocardiograph accepts a specific voltage, capacity and geometry.
For institutional orders, tenders or continuous supply contracts, contact our technical-commercial department to confirm compatibility, lead times and formalised quotation.