Description
1. Reliable power for your Biocare electrocardiograph
The battery for the Biocare ECG-1200 electrocardiograph (ref. Cahnos 88881242) is the power replacement indicated for the portable Biocare ECG-1200 electrocardiograph, replacing the original reference HYLB-293. Designed for cardiology departments, clinics and primary care, it allows complete cardiac examinations to be performed without depending on a mains supply, keeping the equipment operational during transfers, emergencies and clinical situations where continuity of recording is critical. It is a rechargeable lithium-ion cell, ready to install and compatible with the device’s original charger.
2. How this battery works
The Biocare ECG-1200 electrocardiograph is a portable electrocardiographic recording device that integrates signal acquisition, display and internal storage. This 14.8 V, 2.6 Ah (38.48 Wh) battery powers the acquisition module, display and recording electronics during off-grid working sessions. Its lithium-ion chemistry provides a stable discharge curve: the voltage remains practically constant until the end, which prevents sudden interruptions mid-examination and protects the integrity of stored traces. The positive-locking connector fits directly into the rear compartment of the device, without the need for adapters or wiring modifications, and the internal protection circuit (BMS) monitors the charge and discharge of the cell, adding an extra layer of safety to the assembly.
3. Technical Specifications
| Application | Electrocardiographs Biocare ECG-1200 |
| Original reference | HYLB-293 |
| Battery type | Lithium-ion (Li-ion), rechargeable |
| Nominal voltage | 14.8 V |
| Capacity | 2.6 Ah (2600 mAh) |
| Energy | 38.48 Wh |
| Weight | Approximately 0.35 kg |
| Dimensions | 60 x 70 x 35 mm |
| Device manufacturer | Biocare |
| Presentation | Unit |
Note: the voltage, capacity and energy indicated correspond to the declared specification for reference HYLB-293. Always check the compartment and connector of your unit before replacement.
4. Equivalences and Cross-References
There is no equivalence table validated by the manufacturer Biocare that authorises third-party batteries for the ECG-1200. The references listed below come from replacement battery manufacturers that claim to replace reference HYLB-293; they are classified as comparable by category (not 1:1 interchangeable), so before replacing, each one must be verified individually: voltage (14.8 V), capacity, chemistry (Li-ion), connector and compartment dimensions.
| Manufacturer / Brand | Family / Model | Code / Reference | Equivalence level | Technical differences / Remarks |
| Cameron Sino | Medical Series (Biocare) | CS-ECG121MD | Comparable by category (not interchangeable 1:1) | Li-ion 14.8 V / 2600 mAh (38.48 Wh). Declared as a replacement for HYLB-293 and HYLB-683 for the ECG-1200, ECG-1201 and ECG-1210 models in specialised distribution datasheets; declared dimensions 67.50 x 40.10 x 36.50 mm, different from those in this datasheet: verify connector and compartment before replacement. |
| Cameron Sino | Medical Series (Biocare) | CS-ECG122MD | Comparable by category (not interchangeable 1:1) | Li-ion 14.8 V / 3400 mAh (≈50.32 Wh), ≈261 g; declared dimensions 67.50 x 40.10 x 36.80 mm. Replaces HYLB-293 with higher capacity; verify compatibility with the original charger and fit in the compartment. |
Within the device manufacturer itself, reference HYLB-683 is used on the market as an alternative pack for the same family of equipment (ECG-1200, ECG-1201 and ECG-1210), according to distribution sources; official Biocare data must be confirmed before use, as the capacities declared on the market vary between 2600 mAh and 3400 mAh.
There is no equivalence table validated by the manufacturer that authorises third-party batteries; consult the technical department before use in tenders. Before any replacement with other brands’ spare parts, voltage, capacity, chemistry, connector and dimensions must be checked against the specific unit.
5. Selection tips and variants of interest
Identify the exact model: this battery corresponds to the Biocare ECG-1200 electrocardiograph. Do not interchange it with batteries from other models of the same brand without technical validation: each device mounts a cell with specific voltage, capacity and dimensions, although some distributors associate the same reference family (HYLB-293 / HYLB-683) with the ECG-1200, ECG-1201 and ECG-1210 models. Always confirm the compartment and connector of your unit.
Battery care: keep the cell charged if the device is to remain idle for long periods and replace the battery when battery life is noticeably reduced or the device indicates low battery. Use only the electrocardiograph’s original charger to respect the Li-ion charging parameters.
Variants of the same Biocare family at Cahnos: battery for Biocare ECG-1215 MFR HYLB-952 (ref. 88889366, same characteristics 14.8 V / 2.6 Ah), battery for Biocare ECG-9803 MFR HYLB-114A (ref. 88889365) and battery for Biocare ECG-3010 MFR HYLB-947 (ref. 88889367). Do not interchange these references between models: each electrocardiograph accepts a specific voltage, capacity and geometry.
For institutional orders, tenders or ongoing supply contracts, contact our technical-commercial department to confirm compatibility, lead times and formalised quotation.