Description
1. Introduction
Keep your ZOLL AED Pro defibrillator always operational with the replacement battery that matches the unit’s original equipment (ref. 8000-0860-01, DSA AED-Pro MFR). This is a non-rechargeable lithium-manganese primary cell that eliminates any charging and maintenance routine: the AED Pro remains on standby with full response capability and only requires you to periodically check the expiry date on the packaging. An essential solution for emergency services, ambulances, civil protection, industrial environments and any care point that manages a resuscitation device operational 24 hours a day.
2. Technical explanation
The ZOLL AED Pro supports two power strategies: rechargeable battery for intensive use and non-rechargeable battery for prolonged or intermittent deployments. Reference 8000-0860-01 corresponds to the non-rechargeable lithium-manganese (LiMnO₂) battery, a primary cell that delivers a voltage of 12 V and a capacity of 4.2 Ah directly to the device. Being single-use, the AED Pro requires no charging cycles or cell status monitoring: the user only needs to check the date on the packaging and replace the battery when depleted. This is the option recommended by ZOLL for devices intended for long standby periods or infrequent use, where a rechargeable battery would lose charge through self-discharge and require a maintenance routine that this solution completely eliminates. Replacement is manual, quick and requires no tools.
3. Technical Specifications
| Manufacturer | ZOLL Medical Corporation |
| Manufacturer reference | 8000-0860-01 (DSA AED-Pro MFR) |
| Reference Cahnos | 88888634 |
| Battery type | Disposable, non-rechargeable (primary cell) |
| Chemistry | Lithium-manganese (LiMnO₂) with high energy density |
| Nominal voltage | 12 V |
| Capacity | 4.2 Ah |
| Rechargeable | No |
| Maintenance | Maintenance-free |
| Battery life | Up to 300 shocks at 200 J or 15 h of ECG monitoring |
| Replacement notice | After approx. 200 shocks at maximum energy |
| Shelf life | 2-3 years (up to approx. 4 years on standby depending on usage conditions; check package date) |
| Dimensions | 168 x 75 x 45 mm |
| Weight | 385 g approx. |
| Operating temperature | -20 °C to +60 °C (according to distributor’s data sheet) |
| Compatibility | Defibrillator ZOLL AED Pro (exclusive) |
| Use | Single-use |
| Presentation | Unit |
Technical note: the data on this sheet have been verified against the official ZOLL documentation and correct previous descriptions that cited 3.6 V / 2500 mAh: the actual power supply of the AED Pro with this reference is 12 V / 4.2 Ah and its nature is that of a non-rechargeable primary battery.
4. Equivalences and Cross-References
This battery matches the original ZOLL unit ref. 8000-0860-01 (exact reference equivalence within the same manufacturer: identical to the AED Pro’s standard battery). However, there is no manufacturer-validated equivalence table that allows this battery to be replaced with that of another defibrillator: each manufacturer uses its own chemistry, connector and management electronics. The following references share the same typology (primary lithium batteries for AEDs) and are classified as comparable at category level, not interchangeable 1:1.
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
| Philips | HeartStart FR3 | 989803150161 (Cahnos 88888783) | Comparable by category (not interchangeable 1:1) | Primary lithium-manganese dioxide battery, 12 V; connector and management electronics exclusive to Philips. Different capacity and autonomy (up to 300 shocks). |
| CU Medical | i-PAD NF1200 (MRF family) | CUSA0601F (Cahnos 88888831) | Comparable by category (not interchangeable 1:1) | Same Li-MnO₂ chemistry and 12 V / 4.2 Ah, non-rechargeable; connector, pack dimensions and management electronics proprietary to the i-PAD. |
| Welch Allyn | DSA AED 10 | 001852 / 1852 (Cahnos 88888647) | Comparable by category (not interchangeable 1:1) | Primary lithium cell 12 V but 1.4 Ah; lower capacity and different compartment format from the AED Pro. |
| Defibtech | DSA-DEA 5 Years | DBP-1400 (Cahnos 88888845) | Comparable by category (not interchangeable 1:1) | Primary lithium battery for AEDs of 15 V / 1.4 Ah; voltage and connector different from the AED Pro (12 V). |
| Defibtech | DSA-DEA 7 Years | DBP-2800 (Cahnos 88888931) | Comparable by category (not interchangeable 1:1) | Primary lithium battery of 15 V / 2.8 Ah, up to 300 shocks or 7 years; not interchangeable with the AED Pro. |
There is no manufacturer-validated equivalence table that allows the AED Pro battery to be replaced with one from another brand; consult the technical department before use in tendering. Before accepting any alternative battery, the following must be verified one by one: voltage (12 V), capacity (4.2 Ah), chemistry (primary non-rechargeable LiMnO₂), pack dimensions and compartment connector.
5. Selection tips and variants of interest
- Expiry management: as this is a primary battery, establish a FIFO stock rotation and check the date on the packaging during the AED Pro’s periodic checks. Replace the battery before its expiry date even if the device has not recorded any shocks.
- Recommended use: optimal for devices with infrequent use or long standby periods. If your service carries out regular and intensive interventions, consider with the technical department the alternative of a rechargeable battery for the AED Pro.
- Accessories: equip the device with compatible original electrodes: Stat-Padz II (8900-0801-01), CPR-D-Padz (8900-0800-01) for compression guidance or Pedi-Padz II (8900-0810-01) if you attend to a paediatric population.
- Mixed ZOLL fleets: each model uses its own battery (e.g. AED 3 ref. 8000-000696, X Series ref. 8000-0580-01 or XL Series M ref. 8000-0500-02); this reference 8000-0860-01 is exclusive to the AED Pro and is not interchangeable with other series.
- Recycling: deposit the depleted battery at the designated WEEE collection points in accordance with current regulations (regulated lithium transport).
- Tenders and volume orders: confirm references, quantities and expiry dates with the Cahnos technical department before placing large-volume orders.