Ni-Cd battery 14.4 V 1.9 Ah for Defibrillator Schiller/Odam DefiGard 3002 (Bruker 3002 IH) | Ref. 88888445

48,00 €

Rechargeable nickel-cadmium (Ni-Cd) battery, 14.4 V and 1.9 Ah for the defibrillator Schiller/Odam DefiGard 3002 (Ref. 88888445), with Cs format cells and an approximate energy of 27.4 Wh. Direct replacement, no adapters or tools: restores the device’s autonomy during ECG monitoring, power-on self-test and emergency discharge, and recharges with the defibrillator’s own integrated charger. Installation in minutes, approximate weight 0.612 kg, long service life with proper maintenance and recycling in accordance with WEEE regulations. Solution indicated for hospital emergencies, ambulances and medical transport.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
88888445

Description

Ni-Cd 14.4 V 1.9 Ah battery for Schiller/Odam DefiGard 3002

Keep your defibrillator Schiller/Odam DefiGard 3002 always ready for action with this rechargeable nickel-cadmium (Ni-Cd) battery, 14.4 V and 1.9 Ah, reference 88888445. This is a direct replacement part that will restore full autonomy to the equipment, eliminate low battery warnings and guarantee an immediate response in emergencies. A reliable and cost-effective solution compared to the official replacement, designed for emergency services, critical care units, ambulances and medical transport.

How this battery works: technical explanation

The DefiGard 3002 defibrillator is a lightweight defibrillation and monitoring device designed by the medical division of Odam/Bruker (later integrated into Schiller), capable of operating connected to the mains or powered by its internal battery. While the device is plugged in, the battery remains in charging mode; when disconnected, moved or during a power cut, it automatically takes over powering the monitoring electronics, display, recording and discharge stage, without interruption of operation.

The Ni-Cd 14.4 V with 1.9 Ah capacity was the original factory configuration of this platform (approximately 27.4 Wh of energy), assembled on Cs format cells manufactured by Panasonic, according to the technical data sheet from specialised distribution (Exalium/VLAD, ISO 13485, with CE declaration of conformity). Compared to lead cells, it offers higher energy density per weight; compared to Ni-MH, it tolerates intense and rapid discharges well, typical of defibrillation. A degraded cell manifests as loss of autonomy, restarts or low battery messages during self-test; preventive replacement with this reference restores the original behaviour of the device.

Technical specifications

Technical data taken from the product data sheet and cross-checked with specialised distribution documentation (Exalium/VLAD technical data sheet with CE declaration of conformity):

Parameter Detail
Reference Cahnos 88888445
Type / technology Rechargeable nickel-cadmium (Ni-Cd) battery, maintenance-free
Nominal voltage 14.4 V
Capacity 1.9 Ah (approximately 27.4 Wh of energy)
Cells Cs format, with Panasonic cells (according to distribution technical data sheet)
Approximate weight 0.612 kg
Rechargeable Yes, via the defibrillator’s built-in charger
Compatibility Defibrillator Schiller/Odam DefiGard 3002; platform also marketed under the Bruker brand as 3002 IH / 3002 ICH and Defiscope DS
Mounting type Direct replacement in the battery compartment, without adapters or special tools
Presentation 1 unit
Recycling Do not dispose of as municipal waste; recycle in accordance with RAEE/WEEE regulations

Equivalences and cross-references

Schiller does not publish an official equivalence table authorising third-party batteries for the DefiGard 3002. The DefiGard 3002 / 3002 IH / 3002 ICH platform (also marketed by Bruker) is supplied on the market with Ni-MH chemistry batteries of 14.4 V and higher capacity; the alternatives indicated match in voltage and the intended device, but do NOT reproduce the original Ni-Cd 1.9 Ah configuration, so they are classified as comparable by category, not 1:1 interchangeable, and require verification of dimensions, connector and orientation against the specific device before replacement.

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
Bruker (OEM designations of the same platform) DefiGard 3002 / 3002 IH and Defiscope DS 12N-3000SCR · 12N-2000SCR · 12N-1800SCR Comparable by category (not interchangeable 1:1) OEM codes consistently cited by specialised distribution for the DefiGard 3002/3002 IH platform; they are supplied in Ni-MH chemistry of 14.4 V with capacities of 1.8–3.0 Ah, compared to the original Ni-Cd 1.9 Ah. Verify the installed cell.
Specialised distribution (compatible replacement) Medical battery for Schiller DefiGard 3002 / 3002 IH and Defiscope DS CS-BKR300MD Comparable by category (not interchangeable 1:1) Ni-MH 14.4 V 3000 mAh (43.2 Wh); dimensions 269.9 × 44.7 × 23.2 mm and weight approx. 951 g compared to 0.612 kg for the Ni-Cd 1.9 Ah. Different chemistry and capacity; not original Schiller; confirm housing and connector.
Specialised distribution (IH/ICH variant) DefiGard 3002 ICH / 3002 IH MGN0259 (CS-DEF300MD) Comparable by category (not interchangeable 1:1) Reference cited for the IH/ICH variants of the DefiGard 3002 in Ni-MH 14.4 V 3000 mAh; dimensions approx. 275 × 23 × 45.5 mm and weight approx. 750 g. Corresponds to another variant of the device and does not equate 1:1 to the base model without verifying the installed battery.
Specialised distribution (universal replacement for the platform) Bruker 3002 IH / Schiller DefiGard 3002 / DefiGard 3002 IH SL80536-2 Comparable by category (not interchangeable 1:1) Ni-MH 14.4 V 3000 mAh; weight 700 g and dimensions 274 × 28 × 45 mm, with higher capacity than the original Ni-Cd. Aftermarket replacement for the same platform; verify dimensions and connector before fitting.

There is no equivalence table validated by the manufacturer (Schiller) for this battery; consult with the technical department before use in tenders. As a reference, specialised distribution supplies for the same platform the cited designations 12N-3000SCR / 12N-2000SCR / 12N-1800SCR, CS-BKR300MD, MGN0259 (CS-DEF300MD) and SL80536-2, always in Ni-MH chemistry and higher capacity. Attention: in the Cahnos catalogue, the batteries of the Schiller/Odam family are specific to each device; those for the DefiGard 2000 FRED (Ref. 88888441, Ni-Cd 12 V 1.9 Ah) and the DefiGard 4 / MiniDef 2 (Ref. 88888446, Ni-Cd 12 V 1.3 Ah) must not be confused with the present reference.

Selection tips and variants of interest

Before replacing the battery of your DefiGard 3002, verify three parameters on the label of the removed cell: voltage (14.4 V), technology (Ni-Cd) and capacity (1.9 Ah). If your device is a standard configuration DefiGard 3002, this reference is the correct one.

Do not confuse it with other batteries in the Schiller/Odam family: the DefiGard 2000 FRED uses the Ni-Cd 12 V 1.9 Ah (Ref. 88888441), the DefiGard 4 / MiniDef 2 the Ni-Cd 12 V 1.3 Ah (Ref. 88888446) and the DefiGard 5000 a Li-Ion 10.8 V 4.3 Ah (Ref. 88888542). Each variant fits a specific device: always check the installed cell before purchasing.

Preventive maintenance: Ni-Cd cells can develop memory effect if always partially recharged; periodically perform a full discharge and recharge cycle. If the device is to remain switched off for long periods, keep the battery charged and let the power-on self-test verify its status. For tenders and equipment fleets, contact our technical department indicating the model, serial number and reference of the installed battery; we will confirm compatibility before formalising the order and offer you special volume conditions.

Additional information

Technology

Nickel-cadmium (Ni-Cd), rechargeable, maintenance-free

Nominal voltage

14.4 V

Capacity

1.9 Ah (approx. 27.4 Wh)

Equipment reference

Defibrillator Schiller/Odam DefiGard 3002 (also marketed as Bruker 3002 IH)

Cells

Cs format, Panasonic cells (according to distribution technical data sheet)

Weight

Approx. 0.612 kg

Recycling

RAEE/WEEE

Use

Hospitals, emergency departments, ambulances and medical transport

Approximate weight

0.612 kg

Compatibility

Defibrillator Schiller/Odam DefiGard 3002; Bruker 3002 IH / 3002 ICH and Defiscope DS platform

Mounting type

Direct replacement in the battery compartment, without adapters or tools

Presentacion

Unit

Reviews

There are no reviews yet.

Be the first to review “Ni-Cd battery 14.4 V 1.9 Ah for Defibrillator Schiller/Odam DefiGard 3002 (Bruker 3002 IH) | Ref. 88888445”