Description
1. Commercial Introduction
The Physio-Control LIFEPAK 1000 battery marketed by Cahnos (Ref. 88888490) is the original power replacement for the LIFEPAK 1000 semi-automatic external defibrillator, one of the most widely used defibrillation devices in out-of-hospital care, ambulances, workplaces and public defibrillation programmes. It is a primary lithium manganese dioxide (LiMnO₂) cell, non-rechargeable, 12 V and 4.5 Ah, which keeps the device fully available for years with minimal maintenance. An essential spare part for maintenance services, biomedical engineering and purchasing departments that need traceable replacements, with confirmed factory reference and ready to act at the critical moment.
2. Technical Explanation
The LIFEPAK 1000 is a semi-automatic external defibrillator that analyses the cardiac rhythm and delivers biphasic shocks in the event of cardiopulmonary arrest. Its availability depends entirely on an autonomous power supply: the internal battery powers the device’s periodic self-tests, rhythm analysis, voice prompts and the shock. Maintenance programmes therefore require the battery to be replaced preventively according to the installation date indicated on the label, without waiting for the device to warn of depletion.
This reference uses primary lithium manganese dioxide (LiMnO₂) chemistry, sealed and non-rechargeable: it requires no charger or charge cycles, retains its stored energy for long periods and offers approximately 4 years of standby service life when installed in the device, according to the manufacturer’s technical documentation and specialist distribution. The replacement kit includes the Battery Pak (Cat. No. 11141-000156), the discharger (P/N 3301604) and safe disposal instructions; the battery itself incorporates a charge status verification indicator (grey button). Replacement is carried out in seconds without tools: the depleted cell is removed, the new one inserted and the device is operational.
Note on the code: the reference appears in the previous datasheet as 111141-000100, but the official part number verified in manufacturer sources and in GUDID is 11141-000100 (the form 111141-000100 is a transcription with an added digit and must not be used in orders or tenders).
3. Technical Specifications
Data cross-checked against the GUDID regulatory database (FDA), the device manufacturer’s documentation and specialist distribution:
| Parameter | Specification |
|---|---|
| Reference Cahnos (SKU) | 88888490 |
| Manufacturer reference (MFR) | 11141-000100 (Physio-Control, Inc. / Stryker) — confirmed in GUDID (UDI-DI 00883873793497, class III) |
| Alternative part numbers cited | 11141-000101, 11141-000156, 3206245-000, 3206245-004, 21300-006054, 3205379-005 (according to specialist distribution) |
| Kit contents | Battery Pak (11141-000156) + discharger (3301604) + safe disposal instructions |
| Battery type | Lithium manganese dioxide (LiMnO2), primary cell, non-rechargeable |
| Nominal voltage | 12 V |
| Nominal capacity | 4.5 Ah (4500 mAh) |
| Approximate energy | ≈ 54 Wh (nominal calculation 12 V × 4.5 Ah) |
| Standby life | ≈ 4 years installed in the device (periodic self-tests) |
| Rechargeable | No — preventive replacement |
| Charge verifier | Status indicator with button (grey test gauge) integrated into the battery |
| Approximate dimensions | ≈ 203 × 57 × 33 mm (according to specialist distribution datasheets) |
| Approximate weight | ≈ 0.42 kg |
| Installation | Direct replacement in the equipment compartment, without tools |
| Compatibility | Physio-Control LIFEPAK 1000 external defibrillator (exclusive) |
| Application | Emergency defibrillation in out-of-hospital care and medical transport |
| Presentation | 1 kit (1 unit) |
| Recycling | Discharge completely before handling in accordance with WEEE regulations |
Technical note: the voltage (12 V), capacity (4.5 Ah) and chemistry (LiMnO₂) correspond to the specification of reference 11141-000100 verified in authorised distribution sources and in the official Stryker store; the dimensions and weight come from spare parts suppliers’ datasheets and must be checked against the compartment of the specific unit before fitting. Always respect the installation deadline indicated on the label.
4. Equivalences and Cross-References
Reference 11141-000100 is confirmed in the GUDID regulatory database (Physio-Control, Inc., UDI-DI 00883873793497, description LP1000 ASSEMBLY BATTERY REPLACEMENT KIT, class III). Within the manufacturer itself, the part numbers 11141-000101, 11141-000156, 3206245-000, 3206245-004, 21300-006054 and 3205379-005 are consistently cited in specialist distribution and in the official Stryker store as variants or components of this same battery for the LIFEPAK 1000. The independent manufacturer references listed below belong to this same category, have been cross-checked against battery manufacturer catalogues and specialist distribution, and are classified as comparable by category, not 1:1 interchangeable: before replacement, the voltage (12 V), capacity (4.5 Ah), chemistry (LiMnO₂ vs Li-Ion), connector and compartment housing must be verified.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Physio-Control (Stryker) | Official LIFEPAK 1000 battery (replacement kit) | 11141-000100 | Exact reference equivalence (same manufacturer) | Official part number of the product analysed; confirmed in GUDID (UDI-DI 00883873793497, class III). Kit: Battery Pak 11141-000156 + discharger 3301604. |
| Physio-Control (Stryker) | Battery Pak component of the kit | 11141-000156 | Exact reference equivalence (same manufacturer) | Battery Pak included in kit 11141-000100; consistently cited in authorised distribution catalogues and in the official Stryker store as the battery pack for the LIFEPAK 1000. |
| Physio-Control (Stryker) | Alternative service numbers | 11141-000101, 3206245-000, 3206245-004, 21300-006054, 3205379-005 | Exact reference equivalence (same manufacturer) | Alternative codes consistently documented in specialist distribution for the same LIFEPAK 1000 battery; confirm with the manufacturer before use in tenders. |
| OSI Batteries (Unipower) | LifePak 1000 biomedical battery (OEM only) | B11485 | Comparable by category (not interchangeable 1:1) | Lithium 12 V / 4.5 Ah replacing 11141-000100 and 11141-000156; distribution labelled as OEM only; verify connector, expiry date and installation deadline. |
| KingSener / BatteryMall | LIFEPAK 1000 AED replacement | 11141-000100 (independent replacement) | Comparable by category (not interchangeable 1:1) | 12 V / 4.5 Ah replacement with Li-Ion chemistry (as opposed to the original LiMnO₂); independent spare parts manufacturer, without authorisation from the device manufacturer; validate connector and electronic management before fitting. |
| Axcom | LIFEPAK 1000 Li-Metal battery | LP1000-O | Comparable by category (not interchangeable 1:1) | Non-rechargeable 12 V / 4.5 Ah battery advertised as original and a replacement for 11141-000100 / 11141-000101; verify batch and origin before replacing. |
There is no equivalence table validated by the manufacturer (Physio-Control / Stryker) that authorises third-party batteries for the LIFEPAK 1000 model; consult the technical department before use in tenders. AED batteries are proprietary and differ in connector, voltage, chemistry and electronic management: batteries from other LIFEPAK series are also not interchangeable (CR2 11141-000165, CR Plus 11403-000001, LIFEPAK 500 11141-000158 or the rechargeable packs for LIFEPAK 15 and LIFEPAK 20e), each with its specific voltage, chemistry and housing.
5. Selection tips and variants of interest
- Identify the exact model of your device: this 12 V battery is exclusive to the LIFEPAK 1000 defibrillator. Do not install it in other models in the LIFEPAK family, whose batteries are not compatible with each other.
- Always order by reference: quote code 88888490 or the official reference 11141-000100 (never 111141-000100) to avoid confusion with other references in the family.
- Preventive replacement: replace the battery approximately every 4 years from installation or at the first low battery warning; observe the installation deadline printed on the label before putting it into service.
- Do not attempt to recharge it: it is a long-life disposable primary cell; it does not accept chargers or charge cycles.
- Stock rotation (FIFO): in AED fleets, establish rotation by expiry date and keep at least one reserve battery per device for immediate replacement.
- Accessories from the same family: complete maintenance with the original consumables for the LIFEPAK 1000 (adult multifunction electrodes and paediatric mode key) available in the authorised spare parts market.
- Recycling: do not dispose of the used battery as municipal waste; fully discharge it with the included discharger and manage it in accordance with WEEE regulations.
- For institutional orders, tenders or ongoing supply contracts, contact our technical-commercial department to confirm compatibility with your defibrillator fleet, delivery times and formal quotation.