Rechargeable Battery Kit 14.4V 1.8Ah for Patient Lift Quick Raiser · Swing 4+4+4D (Molift/PRAXIS) | Original Ref. 0540000 | Ref. Cahnos 88888394

66,00 €

Rechargeable battery kit 14.4V 1.8Ah for Quick Raiser and Swing 4+4+4D patient lifts (Molift/PRAXIS), corresponding to the original reference 0540000 (Power Pac). Quality Exalium replacement that restores the equipment’s autonomy for safe patient lifting and transfer operations. It features 25.92Wh of energy, dimensions of 140 x 75 x 40 mm and approximately 0.6 kg in weight: direct installation in the lift’s compartment, without modifications. Ideal for hospitals, care homes, home care and tenders for transfer hoist fleets.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
0159025

Description

1. Reliable power for your patient lift

Keep your Quick Raiser or Swing 4+4+4D patient lift always operational with this 14.4V 1.8Ah rechargeable battery kit (Ref. Cahnos 88888394), corresponding to the device’s original reference 0540000 (Molift Power Pac) from manufacturer PRAXIS. It is the replacement designed to guarantee the equipment’s autonomy in rooms, assisted bathrooms, care homes and intra-hospital transfers, avoiding interruptions during patient lifting and transfer.

It is a kit for direct installation in the lift’s battery compartment, restoring the equipment to full operation in a few minutes and at a very contained cost compared to the official replacement. Ideal for medical electronics services, hospitals, residential centres and supply contracts for medical supplies.

2. How this battery works in the patient lift

The Quick Raiser / Swing lift uses its battery as the power source for the lifting actuators when the equipment is not connected to the mains. While the charger is plugged in, the pack remains charging; when disconnected, the battery takes over powering the control electronics and the hydraulic or electric motor that performs the patient lifting and lowering manoeuvre.

Its construction from rechargeable nickel cells (Ni-MH chemistry according to the data sheet; specialised distribution documentation identifies the original reference 0540000 as Ni-Cd) supports repeated charge and discharge cycles. A degraded battery causes slow descents, low battery warnings or stops of the manoeuvre at mid-height; preventive replacement with this reference restores autonomy and transfer safety.

3. Technical Specifications

Technical data for the kit taken from the product data sheet and cross-checked with specialised distribution documentation:

Parameter Value
Application Quick Raiser and Swing 4+4+4D patient lifts (Molift / PRAXIS)
Original manufacturer reference 0540000 (Molift Power Pac)
Reference Cahnos 88888394 (SKU 0159025)
Technology Ni-MH (Nickel-Metal Hydride) according to data sheet; distribution documentation identifies the original 0540000 as Ni-Cd
Nominal voltage 14.4 V
Capacity 1.8 Ah
Energy 25.92 Wh
Dimensions (L x W x H) 140 x 75 x 40 mm
Approximate weight 0.6 kg
Rechargeable Yes
Professional use Hospitals, clinics, care homes, home care and intra-hospital transport
Recycling Do not dispose of as household waste; recycle in accordance with WEEE regulations

4. Equivalences and Cross-References

Reference 0540000 is the original battery pack from the device manufacturer (PRAXIS/Molift) for the Quick Raiser and Swing 4+4+4D lifts. Neither PRAXIS nor Molift-Etac publishes an official equivalence table authorising third-party batteries for this reference; the alternatives indicated below share nickel chemistry, voltage (14.4V) and capacity window (1.8-1.9Ah) and are classified as comparable by category, not 1:1 interchangeable, so connector, orientation and fit must be verified against the removed pack before replacement.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Molift (Etac) / PRAXIS Power Pac (original device battery) 0540000 Comparable by category (not interchangeable 1:1) Original reference from the device manufacturer (Quick Raiser · Swing 4+4+4D), documented in official catalogue and specialised distribution: Ni-Cd 14.4V 1.8Ah pack. This is the reference that this kit replaces; verify connector and orientation.
NCE Cell insert for Molift Power Pac N1200INS Comparable by category (not interchangeable 1:1) Ni-Cd 14.4V 1.8Ah insert cited as a cross reference for 0540000 by a specialised distributor; requires assembly in the original Power Pac housing.
AKKUmed Ni-Cd conversion for Molift Power Pac 0540000 110391-U Comparable by category (not interchangeable 1:1) 14.4V 1.9Ah retrofit carried out on the original housing with CE marking; slightly higher capacity (1.9 vs 1.8Ah).
Laboiteapiles Compatible battery for Molift Power Pac 12-BK300SC Comparable by category (not interchangeable 1:1) Assembled in France; declared compatible with Power Pac Ni-MH 0541000 and Ni-Cd 0540000 (HR23/43 cells). Verify chemistry and connector before assembly.

As support, specialised distribution cross-reference tables also associate this cell window with HR23/43 cells (sub-C nickel format); the Ni-MH variants 0541000 (14.4V 2.6Ah) and 0541000-2 (14.4V 3Ah) of the same Power Pac are comparable by category with this kit due to their higher capacity and different chemistry, and the latter corresponds in the Cahnos catalogue to Ref. 88888391 for the Swing 4+4+4H. There is no equivalence table validated by the manufacturer (PRAXIS/Molift-Etac) authorising third-party batteries for reference 0540000; consult the technical department before use in tenders.

5. Selection tips and variants of interest

Identify the lift model: this kit corresponds to the Quick Raiser and Swing 4+4+4D systems. Always confirm the reference printed on the removed pack (0540000) before purchasing, and do not confuse it with the higher capacity variant 4+4+4H (original Ref. 0541000-2, 14.4V 3Ah), which should only be installed if the equipment allows it.

Chemistry and maintenance: the original pack 0540000 is Ni-Cd; some replacement versions are supplied in Ni-MH. For Ni-Cd chemistry, it is advisable to perform full charges periodically to minimise the memory effect, and not to leave the pack fully discharged for long periods. Replace the battery when the operation loses power or the equipment warns of low battery.

After replacement: fully charge the kit before first use and perform a complete lifting and lowering cycle with no load to confirm correct seating of the contacts.

Tenders and equipment fleets: contact our technical department stating model, serial number and reference of the installed battery; we will confirm compatibility before formalising the order and offer special conditions for volume.

Additional information

Technology

Ni-MH according to data sheet; specialised distribution documentation identifies the original reference 0540000 as Ni-Cd

Nominal voltage

14.4 V

Capacity

1.8 Ah

Energy

25.92 Wh

Manufacturer reference

0540000

Dimensions

140 x 75 x 40 mm

Approximate weight

0.6 kg

Application

Molift Quick Raiser – Swing 4+4+4D patient lifting systems

Compatibility

Quick Raiser and Swing 4+4+4D patient lifts (Molift/PRAXIS)

Rechargeable

Yes

Recycling

WEEE / recycling point

Battery type

Rechargeable battery kit (Exalium replacement) for patient lift

Use

Hospitals, clinics, care homes, home care and intra-hospital transport

Presentacion

Unit

Reviews

There are no reviews yet.

Be the first to review “Rechargeable Battery Kit 14.4V 1.8Ah for Patient Lift Quick Raiser · Swing 4+4+4D (Molift/PRAXIS) | Original Ref. 0540000 | Ref. Cahnos 88888394”

Your email address will not be published. Required fields are marked *