Description
1. Reliable power for your vital signs monitor
Keep your Mindray MEC1000 monitor always operational with this sealed lead-acid (SLA) rechargeable battery of 12V and 2.1Ah, corresponding to the manufacturer’s original reference M05-302R3R (Ref. Cahnos 88888384). It is the spare part designed to guarantee the equipment’s autonomy in emergencies, intra-hospital transfers, operating theatres and any situation where mains power is unavailable, without compromising continuous patient monitoring.
It is a sealed, maintenance-free replacement that installs directly in the equipment’s battery compartment, restoring the monitor to full operation in a few minutes and at a very contained cost compared with the official replacement. Ideal for medical electronics departments, hospitals, clinics and medical supply contracts.
2. Technical explanation: how this battery works
Reference M05-302R3R is the sealed lead-acid cell that Mindray fits as standard in its MEC/PM family multiparameter monitors. While the equipment is connected to the mains, the battery remains in float charge; when it is disconnected, moved or if the supply is interrupted, it automatically takes over powering the display, monitoring electronics and measurement modules without interruption.
Its sealed construction (SLA/VRLA technology, leak-proof and non-spillable) allows installation without risk of leakage and withstands repeated charge/discharge cycles with a typical design life of 3 to 5 years under nominal conditions, provided the equipment’s charge cycle is respected. A degraded battery causes unexpected shutdowns or low-battery warnings during portable use; preventive replacement with this reference restores the monitor’s original autonomy.
3. Technical Specifications
Technical data for the M05-302R3R cell taken from the product datasheet and cross-checked against specialist distribution documentation:
| Parameter | Value |
| Application | Mindray vital signs monitors MEC1000, MEC1200, MEC2000, PM7000, PM8000, Passport 2, Spectrum, Spectrum OR and Trio |
| Original manufacturer reference | M05-302R3R (Mindray) |
| Reference Cahnos | 88888384 |
| Technology | Sealed lead (SLA / VRLA), maintenance-free |
| Nominal voltage | 12 V |
| Capacity | 2.1 Ah (20-hour rate, standard for SLA cells) |
| Energy | 25.2 Wh |
| Dimensions (L x W x H) | 180 x 60 x 23 mm |
| Weight | Approximately 0.720 kg |
| Terminals | Clip type (camcorder style) according to specialised distribution; verify with the cell removed |
| Rechargeable | Yes |
| Estimated life | 3-5 years under nominal conditions (typical of SLA technology) |
| Professional use | Power supply for vital signs monitors in hospitals, emergency departments and transport |
| Recycling | Do not dispose of as municipal waste; recycle in accordance with RAEE/WEEE regulations |
4. Equivalences and Cross-References
Mindray does not publish an official equivalence table authorising third-party batteries for reference M05-302R3R. The cell conforms to the standard 12V sealed lead-acid slim-profile format (~180 x 60 x 23 mm), and the alternatives listed below share chemistry, voltage and capacity window (2.1-2.3Ah); they are classified as comparable by category, not 1:1 interchangeable, and require verification of dimensions, connector and orientation against the specific equipment before replacement.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Power-Sonic | PS series (general purpose SLA) | PS-1221 | Comparable by category (not interchangeable 1:1) | SLA cell 12V/2.1Ah, 178 x 60 x 35 mm, F1 terminals, confirmed in the cell manufacturer’s official datasheet. Same voltage and capacity (2.1Ah); check case height (35 vs 23 mm) and connector before fitting. |
| OSI Batteries (Unipower) | Biomedical battery for Mindray MEC1000 | B00932 (SKU ES2.3-12V-Mindray MEC1000) | Comparable by category (not interchangeable 1:1) | 12V SLA documented specifically as an OEM replacement for M05-302R3R in a specialist biomedical battery distributor’s datasheet; it states 2.3Ah and clip-type connector. Verify capacity and fit in the compartment. |
| GS Yuasa | NP series (reference VRLA cell of the format) | NP2.1-12 / NP2.3-12 | Comparable by category (not interchangeable 1:1) | Standard 12V SLA/VRLA cell with Faston terminals, confirmed in the cell manufacturer’s official datasheet (178 x 34 x 60-64 mm). Case format different from the MEC1000’s slim profile; for use only with housing verification. |
| Alpha Source | OEM replacement for 12V SLA medical monitors | AS00221 / AS00317 | Comparable by category (not interchangeable 1:1) | Cross-references for the 12V/2.3Ah cell of the NP2.3-12 family cited in specialist distribution tables for medical equipment. Confirm terminal version and order dimensions. |
| Interstate Batteries | 12V SLA range | SLA1015 | Comparable by category (not interchangeable 1:1) | 12V/2.3Ah cross-reference included in SLA biomedical battery compatibility tables. Check F1 terminal and dimensions before replacing. |
As support, specialist distribution cross-reference tables also associate this cell window with Panasonic LCT-1912ANK / LC-SA122R3P, MK Battery BMED00317, NCE NP2.3-12FR and Raion RG1221T1; in the Cahnos catalogue, cells of the same family (12V SLA 2.1-2.3Ah) are supplied for the Nihon Kohden Cardiofax ECG-8023G electrocardiograph (Ref. 88888423, MFR X041A) and for the Philips HeartStart XL defibrillator (Ref. 88888255, MFR M3516A), both comparable by category with the M05-302R3R.
There is no equivalence table validated by the manufacturer (Mindray) authorising third-party batteries; consult the technical department before use in tenders.
5. Selection tips and variants of interest
- Identify the equipment: this battery corresponds to the Mindray MEC1000, MEC1200, MEC2000 and PM7000/PM8000 monitors, as well as Passport 2, Spectrum, Spectrum OR, Trio and, depending on installed base, 9030P, PM9000 and VS800. Always confirm the reference printed on the removed cell before purchasing.
- Do not confuse it with other chemistries: some monitors in the family (e.g. VS800) accept on the market a lithium-ion variant (Mindray ref. 110404-O) alternative to the lead one (110594); only one variant fits each unit, so the installed cell and charging electronics must be verified before replacing.
- Check voltage and chemistry: the monitor is configured for 12V sealed lead. Do not install cells of another voltage, chemistry or with integrated wiring without validation from the technical service.
- Preventive maintenance: SLA cells self-discharge slowly at rest; if the equipment is to remain switched off for long periods, recharge it periodically to avoid falling below the recovery threshold (≈10.5V). Replace the battery when autonomy is appreciably reduced or the monitor warns of low battery.
- After replacement: fully charge the battery before first use and allow the monitor to complete its power-on self-test; a full charge/discharge cycle helps recalibrate the low-battery threshold.
- Tenders and equipment fleets: contact our technical department stating model, serial number and reference of the installed battery; we will confirm compatibility before formalising the order and offer special volume conditions.