Description
1. Reliable backup power for your STERIS CMAX table
This set of 2 sealed lead-acid batteries of 12V and 24Ah is the power replacement indicated for the STERIS CMAX operating table, one of the most widely used surgical devices in operating theatres, trauma wards and diagnostic units. With this reference, your table recovers the backup energy needed to keep the elevation, tilt, Trendelenburg and control electronics operational even if the power supply is interrupted or during patient transfer between rooms.
It is a direct replacement solution for medical electronics services, hospital maintenance and institutional purchasing that need traceable spare parts, of consistent quality and with an excellent price-quality ratio compared to the original part.
2. Technical explanation: how this battery works in your equipment
The motorised STERIS CMAX operating tables incorporate a dual power supply system: mains electricity or direct current through internal sealed lead-acid accumulators mounted in a set of 2 units per table. While the table remains connected to the mains, the batteries are kept in float charge; when the equipment is disconnected, the accumulator automatically takes over the power supply to the actuators and control electronics without interrupting the operation.
The cell uses valve-regulated lead-acid (VRLA) chemistry with electrolyte absorbed in glass fibre (AGM), which makes it leak-proof, maintenance-free and non-spillable. It delivers a nominal voltage of 12V with a capacity of 24Ah at a 20-hour rate, in the standard cell format NP24-12 (166 × 175 × 125 mm), with low self-discharge at rest and a typical design life of 3 to 5 years under nominal conditions of use and charging.
3. Technical Specifications
Data for the set and the cell, cross-checked with manufacturer technical data sheets and specialised distribution:
| Characteristic | Specification |
|---|---|
| Reference Cahnos (SKU) | 88888417 |
| Presentation | Set of 2 batteries (the ones fitted to the table) |
| Compatible equipment | STERIS CMAX operating table (2 batteries per table) |
| Reference of the original equipment kit | STERIS P764331223 (12V battery kit, 2 units), according to the official Shop STERIS catalogue |
| Installation | Direct replacement in the table housing, reusing the original wiring |
| Maintenance | Maintenance-free, without electrolyte replacement |
| Recycling | WEEE (lead); deliver to an authorised collection point |
| Cell parameter | Specification |
|---|---|
| Battery type | Sealed lead-acid (SLA / VRLA / AGM), leak-proof, maintenance-free |
| Nominal voltage | 12 V (per battery) |
| Capacity | 24 Ah (20-hour rate) |
| Cell format | NP24-12 (market standard) |
| Dimensions (L × W × H) | 166 × 175 × 125 mm (per cell; verify housing) |
| Approximate weight | ≈ 8.3 – 8.7 kg per cell according to manufacturer; ≈ 19 kg the set |
| Terminals | Verify with the battery removed (screw terminals M5 or Faston F2 depending on batch) |
| Rechargeable | Yes, with the table’s integrated charger |
| Estimated life | 3-5 years under nominal conditions (typical VRLA) |
4. Equivalences and Cross-References
The cell that powers the STERIS CMAX table conforms to the standard sealed lead-acid 12V / 24Ah NP24-12 format, in a 2-unit per table assembly. The references from other brands listed below belong to the same product category (12V and 24Ah VRLA/AGM battery in NP24-12 format) and have been cross-checked against official cell manufacturer data sheets and the official STERIS spare parts store; they are classified as comparable by category, not 1:1 interchangeable, and require verification of the terminal, dimensions and polarity against the specific table before replacement.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| STERIS (OEM of the equipment) | Kit of 2 batteries 12V for CMAX / 3085 SP / 5085 SRT / 4085 table | P764331223 | Comparable by category (not interchangeable 1:1) | Original kit of 2 batteries from the equipment manufacturer, confirmed in the official Shop STERIS store for CMAX and other tables of the brand. OEM part of the equipment, not of the cell. |
| GS Yuasa (EnerSys) | NP series (VRLA/AGM) | NP24-12 / NP24-12B / NP24-12I | Comparable by category (not interchangeable 1:1) | Sealed lead-acid cell 12V / 24Ah, 166 × 175 × 125 mm, screw terminals M5 (variant B) or Faston 0.250″ (F2), ≈ 8.65 kg. Confirmed in the manufacturer’s official data sheet; it is the reference cell format of the CMAX. Verify terminal type and table wiring. |
| Power-Sonic | PS series (general purpose SLA) | PS-12240 | Comparable by category (not interchangeable 1:1) | 12V / 24Ah (20-hour rate) with AGM technology, 166 × 175 × 125 mm. Confirmed in the manufacturer’s official data sheet and documented as equivalent to the NP24-12 format in specialised distribution. Compare terminals (F2 vs M5) before replacing. |
| CSB Battery | GP series (VRLA/AGM) | GP12240 | Comparable by category (not interchangeable 1:1) | 12V with nominal capacity of 24Ah (some replacement tables declare it as 26Ah), 166 × 175 × 125 mm, terminal type NB. Confirmed in the manufacturer’s data sheet; verify capacity, terminal and batch dimensions before replacement. |
There is no equivalence table validated by the equipment manufacturer (STERIS) that authorises third-party batteries for the CMAX table; consult the technical department before using in tenders. Before a replacement, each of the following must be verified one by one: voltage (12V), capacity (24Ah), chemistry (sealed lead-acid VRLA/AGM), terminal type and compartment dimensions (NP24-12 format).
5. Selection tips and variants of interest
Identify your table: this reference supplies the set of 2 batteries of 12V / 24Ah fitted to the STERIS CMAX table. Confirm the reference stamped on the removed battery and the table’s serial number before placing the order.
Check the terminal: depending on the batch and cell manufacturer, the NP24-12 format may have M5 screw terminals or blade terminals (Faston 0.250″); confirm the equipment connector before replacing to avoid damaging the original wiring.
Preventive maintenance: VRLA cells self-discharge slowly at rest; if the table is to remain switched off for long periods, recharge it periodically to prevent the voltage from falling below the recovery threshold. Replace the complete set of 2 units to maintain charge balance when the battery autonomy is appreciably reduced or the table warns of low battery.
Variants of the same family in Cahnos: for other surgical tables we have references such as the 12V / 8Ah battery for Maquet Alphamaquet/BetaMaquet 1150 tables (ref. 88888360, MFR 2270184) or the 12V / 24Ah cell in NP24-12 format for the Maquet Kion ventilator (ref. 88889550). Do not interchange these references between equipment: each table supports a specific voltage, capacity and connector.
For institutional orders, tenders or ongoing supply contracts, contact our technical-commercial department to confirm exact compatibility with your installed base of tables, lead times and formal quotation.