Description
1. Commercial Introduction
The connection cable for training electrodes FIAB (Ref. F5364) is the essential accessory to complete the simulation chain for your defibrillator or training simulator Weinmann Cardiaid. Manufactured by FIAB SpA (Vicchio, Florence, Italy), a European leader in defibrillation, this cable connects the practice pads (trainer pads) to the simulator unit so that CPR students, first responders and healthcare personnel can rehearse the complete action protocol with total realism and safety, without delivering a shock and without wearing out therapeutic electrodes. A hospital-grade spare part designed for training centres, emergency academies and teaching departments. Product sold on quotation: contact our technical-commercial team to formalise your B2B terms.
2. Technical explanation of the equipment
Training electrodes or trainer pads replicate the shape, size and connection system of real defibrillation electrodes, but do not release energy. For the defibrillator or training simulator to detect and read the pads correctly, it is necessary to have the specific connection cable according to the brand of the equipment. This F5364 cable is configured to work with training equipment from the brand Weinmann Cardiaid, guaranteeing a firm coupling and a reliable signal during practice. With it, trainees practise the placement of the pads, the connection of the cable to the equipment, the rhythm analysis sequence and the rescue working rhythm, repeating the sessions as many times as the teaching plan requires.
3. Technical Specifications
The manufacturer’s specifications for this connection cable are detailed below:
| Characteristic | Value |
|---|---|
| Reference FIAB | F5364 |
| Packaging | Single unit |
| Units per box (web) | 1 |
| Compatible with | Weinmann Cardiaid |
Available references
| Reference | Description |
|---|---|
| FIAB-F5364 | Cahnos SKU for the Weinmann Cardiaid training electrode connection cable |
| F5364 | Official manufacturer reference FIAB |
Product technical data
| Parameter | Value |
|---|---|
| Brand | FIAB |
| Manufacturer / original distributor | FIAB SpA (Vicchio, Florence, Italy) |
| Product type | Connection cable for training electrodes (trainer pads) |
| Compatibility | Weinmann Cardiaid training equipment |
| Manufacturer category | Defibrillation > Trainer Pads > Connection Cables |
| Sales unit | Sale on quotation |
4. Equivalences and Cross-References
This product is marketed under the manufacturer’s official reference FIAB F5364, identified in Cahnos with the SKU FIAB-F5364. No certified direct 1:1 equivalents from other manufacturers have been found in reliable sources for this reference: connection cables for training electrodes are specific accessories for each equipment brand, so any replacement must always be verified with the Cahnos technical-commercial department. Within FIAB’s own range of connection cables for trainer pads, the manufacturer offers the following references according to the brand of the training defibrillator:
| Reference FIAB | Compatible brand |
|---|---|
| F5350 | Philips, Laerdal Medical, Agilent |
| F5352 | Medtronic Physio Control, Osatu Bexen, Cardioline, Mindray |
| F5356 | Schiller |
| F5364 | Weinmann Cardiaid (this product) |
| F5366 | Defibtech |
| F5369 / F5386 | Mediana |
| F5389 | Nihon Kohden |
To complete the simulation chain, this cable is combined with the pair of FIAB Trainer Pads training electrodes for adults (Ref. F7999) or its paediatric version (Ref. F7999P), both with snap-type (clip) connection.
5. Selection tips and variants of interest
When setting up your training station, first verify the brand and model of the defibrillator or simulator you are going to use and select the compatible connection cable from the FIAB range: the F5364 is the one indicated for Weinmann Cardiaid training equipment. Combine this cable with the adult training electrodes (F7999) if your teaching plan includes adult population protocols, or with the paediatric version (F7999P) for child scenarios. It is recommended to have several cables and pairs of electrodes per training station to maintain the pace of the sessions without interruptions, and to periodically check the condition of the connectors and the cable insulation. As this is a product sold on quotation, contact Cahnos to request price, availability and B2B terms for your training centre or healthcare organisation.





Reviews
There are no reviews yet.