Description
1. Introduction
The training electrodes ZOLL TRAINER 2 CPR-D•padz (ref. 8900-0804-01) are the official replacement and training supply from ZOLL for the ZOLL AED Plus Trainer simulator and its Trainer 2 version. They are designed to faithfully reproduce the behaviour of the clinical CPR-D•padz electrodes during defibrillation and cardiopulmonary resuscitation practice, but without releasing any discharge energy: a safe, realistic and durable solution for life support schools, CPR academies, emergency services and hospital and industrial training departments that need to train staff in the use of the ZOLL AED.
2. Technical explanation of the equipment and procedure
This kit reproduces, in a teaching format, the family of CPR-D•padz electrodes from ZOLL. It incorporates a reusable electrode with Z-design, whose Z geometry facilitates the quick and correct identification of the electrode position on the manikin’s chest, and a manual CPR hand placement indicator that guides the student in the correct hand position for performing chest compressions, a critical aspect in basic life support training. The electrode is reusable: before each session, a pair of disposable adhesive gel pads, included in the kit, must be applied to it, ensuring adhesion and hygiene throughout the practice. It connects to the simulator via a cable and factory-preconnected connector, which reduces class preparation time. Important: these electrodes are exclusive to training equipment (Trainer) and must not be used on clinical defibrillators or on patients. The ZOLL AED PLUS TRAINER 2 simulator (ref. 8008-0050-10) replicates the voice prompts, rescue scenarios and operating sequence of the real AED, allowing the instructor to evaluate the student’s response without risk.
3. Technical Specifications
| Field | Specification |
|---|---|
| Model | ZOLL TRAINER 2 CPR-D•padz (training electrodes) |
| Manufacturer reference | 8900-0804-01 (ZOLL Medical Corporation) |
| SKU Cahnos | 8900-0804-01 |
| Product type | Training and simulation electrodes (non-clinical) |
| Electrode type | Reusable electrode with Z-design |
| Indicator | Manual hand placement for CPR compressions |
| Gel pads included | 1 pair of disposable adhesive gel pads (apply before each session) |
| Connection | Preconnected, proprietary ZOLL connector for Trainer |
| Compatibility | ZOLL AED Plus Trainer (previous model) and ZOLL AED Plus Trainer 2 (simulator ref. 8008-0050-10 / 8008-0050-01) |
| Shelf life | Up to 5 years from date of manufacture (according to authorised ZOLL distributor; check date on packaging) |
| Use | Exclusively for training and simulation — do not use on patients |
4. Equivalences and Cross-References
There is no manufacturer-validated equivalence table that allows replacing ref. 8900-0804-01 with training electrodes from another manufacturer: the connector, the Z design and the placement indicator are proprietary to ZOLL, so any comparison with other simulation systems should be understood as comparable at category level, not interchangeable 1:1 (the connector, geometry and simulator algorithm differ). Consult the technical department before use in tenders. Within the ZOLL family, the related references are:
| Reference | Product | Related items |
|---|---|---|
| 8900-0804-01 | CPR-D•padz training electrodes for TRAINER (this datasheet) | Reference item |
| 8900-0800-01 | Adult one-piece CPR-D•padz with Real CPR Help (1 pair, clinical use) | Clinical functional equivalent — NOT suitable for training or vice versa |
| 8900-0805-01 | Stat-Padz II training electrodes for TRAINER 2 (box of 6) | Complementary, standard practice without CPR indicator |
| 8900-00861-01 | Pedi-Padz II training electrodes for TRAINER 2 (box of 6) | Supplementary, paediatric practice |
| 8008-0050-10 | ZOLL AED PLUS TRAINER 2 (complete simulator) | Compatible equipment |
| 8008-0007 | Wireless remote control for the TRAINER 2 | Complementary for the instructor |
| 8000-0375-01 | ZOLL TRAINER 2 carry bag | Complementary, protection and transport |
5. Selection tips and variants of interest
- This kit is the recommended replacement when your simulator is used to practise guided chest compressions: the manual placement indicator and the Z-design reinforce the correct hand position in each session.
- Remember that the disposable adhesive gel pads must be applied to the reusable electrode before each practice; consider having spares available to avoid interrupting the course schedule.
- If your training programme only covers AED use without emphasis on CPR, the alternative from the same family is the Stat-Padz II training electrodes (8900-0805-01); for paediatric scenarios, the Pedi-Padz II training electrodes (8900-00861-01).
- These electrodes are exclusive to the Trainer: to equip a clinical ZOLL AED Plus / AED Pro defibrillator, the correct replacement is the clinical CPR-D•padz (8900-0800-01) or other clinical electrodes depending on the model.
- Complete your simulation classroom with the remote control (8008-0007), the ZOLL AED PLUS TRAINER 2 simulator (8008-0050-10) and the transport bag (8000-0375-01).
- Manage stock rotation by expiry: shelf life of up to 5 years from manufacture, but always check the date printed on the packaging.





Reviews