We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Standard paediatric defibrillator electrode with external cable (pair) – Compatible with Nihon Kohden Cardiolife TEC-5500, TEC-5600 and TEC-7600 · Ref. F7961PW

39,75 €

Pair of defibrillator electrodes paediatric multifunction with preconnectable external cable for Nihon Kohden defibrillators of the Cardiolife TEC-5500, TEC-5600 and TEC-7600 series. Indicated for patients under 8 years of age or weighing less than 25 kg, with a reduced active surface area of 40 cm² per electrode, low-impedance conductive adhesive gel, safety anti-shock connector and ECG monitoring for up to 24 h. They withstand up to 50 shocks at 100 J in paediatric configuration. Single-use medical device, without latex or phthalates, class IIb. Reference Cahnos F7961PW with immediate availability and technical support for compatibility verification by model and connector.

International shipping. Import duties and taxes are payable by the recipient.

Reference
F7961PW

Description

1. Introduction

Ensure safe and effective cardiac care for the smallest patients with this pair of standard paediatric defibrillator electrodes with external cable (reference Cahnos F7961PW), a replacement consumable compatible with Nihon Kohden defibrillators from the Cardiolife TEC-5500, TEC-5600 and TEC-7600 series. It is the ideal solution for emergency departments, paediatric intensive care units (PICU), ambulances and any clinical setting that cares for children: a single pair of disposable pads keeps the equipment ready to act in the event of a cardiorespiratory arrest. Available with immediate dispatch from Cahnos and specialised technical support for compatibility verification by model and connector.

2. Technical Explanation

Disposable multifunction electrodes are the interface between the defibrillator and the patient: through them the device analyses the rhythm, delivers the transthoracic shock and monitors the response. This paediatric model allows external transthoracic defibrillation, synchronised cardioversion, non-invasive transcutaneous cardiac pacing and ECG monitoring (up to 24 h), adapted to paediatric physiology. The configuration with external cable (pre-connected electrode) keeps the connector accessible and allows the device to be ready for immediate connection, a decisive advantage in paediatric resuscitation.

In patients under 8 years of age or weighing less than 25 kg, it is essential to attenuate the delivered energy to avoid myocardial injury; therefore, this electrode incorporates a reduced active surface of 40 cm² per electrode and must be used with the device’s paediatric mode switching or with the reduced energy configuration indicated in the defibrillator manual. The low-impedance conductive adhesive gel ensures stable adhesion and a reliable signal, while the metal foil and 1 mm medical foam (FOAM) guarantee a uniform distribution of current. They are single-use: do not reuse under any circumstances and replace after each intervention or upon reaching the expiry date printed on the packaging.

3. Technical specifications and compatibility

3.1 Technical specifications

Parameter Specification
Patient type Paediatric (<8 years / <25 kg)
Cable configuration External cable (pre-connected), 100 cm
Total surface per electrode 75 cm²
Active surface per electrode 40 cm²
Adhesive ring width 1 cm
Supported shocks Up to 50 shocks at 100 J
Conductive gel Low-impedance conductive adhesive gel
Conductive material Metal foil
Backing material Medical foam (FOAM) 1 mm thick
Connection type Safety anti-shock connector
ECG monitoring Up to 24 hours
Regulatory classification Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745)
Reference standards ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993
Primary packaging 1 pair in heat-sealed polyethylene and aluminium bag
Sales format 5 pairs per box (paediatric series)
Shelf life 30 months from the date of production (see expiry date on the packaging)
Storage Dry place, between +5 °C and +35 °C
Composition Latex-free and phthalate-free · Single-use

3.2 Compatibility with defibrillators

Equipment brand Compatible models Cable / required accessories
Nihon Kohden Cardiolife TEC-5500 Series, TEC-5600 Series, TEC-7600 Series Cable JC-755V (TEC-5500, TEC-7600) · Cable K342A / JC-855V (TEC-5600)

Note: always verify the fit of the connector and the cable of your device before use; the TEC-5600 series use the K342A / JC-855V cable, while TEC-5500 and TEC-7600 use JC-755V.

4. Equivalences and Cross-References

The reference F7961PW is a consumable compatible with the aforementioned Nihon Kohden Cardiolife TEC defibrillators, not an original spare part certified by the device manufacturer: the connector and energy management are proprietary to Nihon Kohden. After verifying official manufacturer catalogues and regulatory databases, the following cross-references with codes confirmed in public sources have been identified. In no case is there an official equivalence table validated by the manufacturer for this reference.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Nihon Kohden Disposable adult/child/infant pad (original equipment) P-740K Comparable by category (not interchangeable 1:1) Factory original with 1.5 m cable; reference confirmed in the manufacturer’s official IFU and authorised distributors. Covers AED-2100K/2150K/2151K/2152K, AED-3100 and TEC-5500/5600/7600/7700/8300 series. Connector, gel and labelling proprietary to Nihon Kohden; verify paediatric size and connector fit before replacement.
Nissha Medical Technologies (HeartSync) Defibrillation pads compatible with Nihon Kohden TEC-5500, TEC-5600, TEC-7600, TEC-7700 and TEC-8300 T100AC-NIHONKOHDEN (ref. 6600265H) Comparable by category (not interchangeable 1:1) Code confirmed in the manufacturer’s official catalogue: connector comparable to the original Nihon Kohden and cable included in the packaging. The catalogued version is adult (total surface 371 cm²); verify paediatric size, connector and cable (JC-755V / K342A-JC-855V depending on series) before replacement.

In public sources, no verifiable original paediatric electrode from Nihon Kohden specific to the TEC-5500/5600/7600 series with JC-755V or K342A cable has been found; the manufacturer publishes electrodes with paediatric capability aimed at its AED and TEC-8300 families (P-711, P-713, P-740K). There is no equivalence table validated by the manufacturer that authorises the replacement of original electrodes with third-party pads: the connector and energy management of each defibrillator are proprietary. Any replacement must be validated against the technical data sheet and instructions for use of the defibrillator; consult the technical department of Cahnos before use in tenders.

5. Selection tips and variants of interest

  • Select according to the patient: this paediatric reference is indicated for children under 8 years of age or weighing less than 25 kg. For patients over 25 kg, use the adult version of the same Nihon Kohden connector family (F7961W, external cable JC-765V).
  • Verify the device cable Nihon Kohden: the TEC-5600 series models use the K342A / JC-855V cable; the TEC-5500 and TEC-7600 series use JC-755V. Always check the connector fit before clinical use.
  • Variants of the same Cahnos family: paediatric version with internal cable for Nihon Kohden (F7961P, for TEC-2200, TEC-2300 and TEC-5500 with JC-765V), standard multi-brand version with external cable (F7955PW) or with internal cable (F7955P) which also covers these TEC series, and radiolucent version with internal cable (F7755P) if X-rays or CT scans are anticipated during care.
  • Paediatric mode: ensure the device switches to reduced paediatric energy (up to 100 J) according to the defibrillator manual; on manually adjustable models always select it before the shock.
  • Storage: keep in a dry place between +5 °C and +35 °C and observe the expiry date stated on the packaging (30 months from production); the conductive gel may dry out and reduce its conductivity after the expiry date.
  • Single-use: do not reuse; one pair per patient and clinical event. It is recommended to maintain minimum stock per unit and rotate stock (FIFO).

Immediate availability from Cahnos with technical support for compatibility verification by model and connector before placing volume orders or submitting tenders.

Additional information

Cable type

External cable (pre-connected), 100 cm

Compatibility

Nihon Kohden Cardiolife TEC-5500 Series, TEC-5600 Series and TEC-7600 Series

Device cable

JC-755V (TEC-5500, TEC-7600) · K342A / JC-855V (TEC-5600)

Total surface per electrode

75 cm²

Active surface per electrode

40 cm²

Adhesive ring width

1 cm

Supported shocks

Up to 50 shocks at 100 J

Conductive gel

Low-impedance conductive adhesive gel

Conductive material

Metal foil

ECG monitoring

Up to 24 hours

Regulatory classification

Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745)

Regulatory standard

ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993

Presentation

Pair (2 units); 5 pairs per box (paediatric series)

Sales format

5 pairs per box (paediatric series)

Shelf life

30 months from production (expiry on packaging)

Storage

Dry place, between +5 °C and +35 °C

Use

Single-use, disposable

Latex-free and phthalate-free

Yes

Compatible brand

Nihon Kohden – Cardiolife TEC-5500 Series, TEC-5600 Series, TEC-7600 Series

Required cables

JC-755V (TEC-5500, TEC-7600) · K342A / JC-855V (TEC-5600)

Patient type

Paediatric (

Electrode type

Standard with external cable (pre-connected)

Cable length

100 cm

Backing material

1 mm medical foam (FOAM)

Connection type

Safety anti-shock connector

Primary packaging

Heat-sealed polyethylene and aluminium bag