We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Pair of standard paediatric defibrillation electrodes with external cable, compatible with Weinmann MEDUCORE Standard and MEDUCORE Easy defibrillators (single-use)

39,75 €

Pair of standard paediatric electrodes with external cable (single-use) compatible with Weinmann MEDUCORE Standard and MEDUCORE Easy defibrillators. Indicated for paediatric patients under 8 years or 25 kg, with an active surface area of 40 cm² per electrode, low-impedance conductive adhesive gel and 130 cm cable for quick and safe connection in emergencies. Supports up to 50 shocks, latex-free and complies with Directive 93/42/EEC as a Class IIb device. Always check connector compatibility and expiry date before use. SKU F7964PW.

International shipping. Import duties and taxes are payable by the recipient.

Reference
F7964PW

Description

1. General description

Keep your Weinmann MEDUCORE defibrillator always ready for immediate response with this pair of standard paediatric electrodes with external cable. It is an essential consumable for emergency services, ambulances, clinics and healthcare centres that treat children, as it guarantees effective transmission of the shock with the reduced energy suitable for paediatric patients.

The price corresponds to a pair of electrodes (2 units), individually packaged and ready to be integrated into your centre’s defibrillation protocols. Reference Cahnos: F7964PW.

2. Technical explanation

Multifunction defibrillation electrodes are the interface element between the defibrillator and the patient: they transmit the energy of the transthoracic shock and, in many models, also allow emergency ECG monitoring. In paediatric patients (under 8 years or weighing less than 25 kg) it is essential to attenuate the delivered energy to avoid myocardial injury; therefore this electrode is designed with a reduced active surface area (40 cm² per electrode) and must only be used with the device’s paediatric mode switch or with the attenuator indicated in the defibrillator manual.

The recommended placement is anterolateral (anteroapical position), so that both pads do not come into contact with each other on the child’s chest. They are single-use and disposable: do not reuse under any circumstances, and replace after a maximum of 24 hours of continuous monitoring.

3. Technical Specifications

Brand / compatibility Compatible with Weinmann MEDUCORE Standard and MEDUCORE Easy defibrillators
Electrode type Standard paediatric with external cable
Target population Paediatric patients (< 8 years / < 25 kg)
Total surface (per electrode) 75 cm²
Active surface (per electrode) 40 cm²
Cable length 130 cm
Backing material Medical foam (FOAM) 1 mm thick
Conductive material Metal foil
Conductive gel Low-impedance conductive adhesive gel
Supported shocks 50 shocks (reduced energy in paediatric configuration; verify according to device instructions)
Type of use Single-use, disposable, non-sterile
Classification Medical device class IIb (Directive 93/42/EEC)
Reference standards ANSI/AAMI DF-80; IEC/EN 60601-1; IEC/EN 60601-2-4; ISO 10993
Latex / phthalates Latex-free
Expiry / shelf life Indicated on the packaging (approximately 36 months from manufacture)
Storage Dry place, between +5 °C and +35 °C; protect from direct sunlight
Presentation Price per pair of electrodes (2 units)

4. Equivalences and Cross-References

This electrode belongs to the family of standard paediatric consumables with external cable for defibrillation. Below is the original replacement reference from the equipment manufacturer, verified through authorised distribution sources:

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Weinmann (original spare part) MEDUCORE paediatric defibrillation electrodes (Standard / Standard²) WM45419 Comparable by category (not interchangeable 1:1) Original factory replacement for paediatric electrodes of the MEDUCORE series; depending on the device version, the cable length (0.6 m vs 1.3 m) and electrode surface area (54 cm² vs 40 cm² active) may differ. Verify the exact device version (Standard, Standard² or Easy), cable length and active surface area before replacing.

Within the Cahnos catalogue there are other references of the same family (standard paediatric with external cable) but intended for equipment from other manufacturers, therefore they are not interchangeable with each other: F7961PW (Nihon Kohden), F7967PW (Schiller), F7969PW (Mediana HeartOn) and F7984PW (Instramed). The adult version for the same Weinmann equipment is F7964W.

There is no equivalence table validated by the manufacturer; consult the technical department before use in tender.

5. Selection tips and variants of interest

  • Confirm the exact model of the device: verify that your defibrillator is a Weinmann MEDUCORE Standard or MEDUCORE Easy and that the external cable connector fits correctly into the device socket before clinical use.
  • Do not confuse paediatric and adult versions: the paediatric version is indicated for patients under 25 kg; for adult patients use reference F7964W.
  • Use with AED: do not use these electrodes with fully automatic defibrillators without verifying that the device allows manual switching to paediatric function/energy.
  • Storage and expiry: always check the expiry date and storage conditions (+5 °C to +35 °C, dry place); expired electrodes or those with damaged packaging must not be used.
  • Plan your replenishment: as it is a single-use consumable, it is recommended to maintain a minimum stock per defibrillation unit and rotate stock according to expiry date.

Additional information

Compatibility

Weinmann MEDUCORE Standard / MEDUCORE Easy

Patient type

Paediatric (< 8 years / < 25 kg)

Total surface per electrode

75 cm²

Active surface per electrode

40 cm²

Conductive material

Metal foil

Conductive gel

Low-impedance conductive adhesive gel

Supported shocks

50 shocks

Use

Single-use, disposable

Regulatory classification

Medical device class IIb (Directive 93/42/EEC)

Regulatory standard

ANSI/AAMI DF-80; IEC/EN 60601-1; IEC/EN 60601-2-4; ISO 10993

Storage

Dry place, between +5 °C and +35 °C, protect from direct sunlight

Presentation

Pair of electrodes (2 units)

Brand / compatibility

Compatible with Weinmann MEDUCORE Standard and MEDUCORE Easy

Electrode type

Standard paediatric with external cable

Target population

Paediatric patients (< 8 years / < 25 kg)

Cable length

130 cm

Backing material

Medical foam (FOAM) 1 mm thick

Type of use

Single-use, disposable, non-sterile

Classification

Medical device class IIb (Directive 93/42/EEC)

Latex, phthalates

Latex-free

Shelf life

Approximately 36 months from manufacture

Latex

Latex-free

Reviews

There are no reviews yet.

Be the first to review “Pair of standard paediatric defibrillation electrodes with external cable, compatible with Weinmann MEDUCORE Standard and MEDUCORE Easy defibrillators (single-use)”

Your email address will not be published. Required fields are marked *