Description
Compatible paediatric electrodes for Physio-Control LIFEPAK defibrillator
1. Introduction
Ensure safe and effective care for the smallest patients with this pair of compatible and disposable paediatric electrodes for defibrillator,, reference 33603 (SKU GM33603). It is the clinical replacement indicated for schools, nurseries, sports centres, paediatric practices and any cardioprotected location with children: when these pads are connected, the defibrillator delivers a shock adapted to paediatric physiology without the need for manual configuration. A medical device manufactured in Italy, latex-free, that keeps your equipment always operational and ready for the paediatric population.
2. Technical explanation of the equipment and procedure
Automated external defibrillators (AED) of the LIFEPAK family analyse the heart rhythm through disposable multifunction electrodes. This pair of paediatric electrodes incorporates an energy reduction system: the defibrillator output of 200 J is reduced to approximately 50 J at the patient, the dose adapted to the paediatric myocardium according to international cardiopulmonary resuscitation (CPR) guidelines, which set the age limit for paediatric treatment at 8 years, corresponding to about 25 kg according to standard growth curves. The pads are placed following the anatomical diagrams on the packaging and are single-use: they must be replaced after each intervention or upon reaching the expiry date printed on the packaging.
3. Technical Specifications
Paediatric multifunction reduced-energy electrode from the range of compatible electrodes, in pair presentation (kit of 2 pieces).
3.1 Available references
| Reference | Model | Sales unit |
|---|---|---|
| GM33603 | COMPATIBLE PAEDIATRIC PADS for defibrillator Medtronic Physio-Control (see also 55004) | Kit of 2 units (1 pair) |
| GM55004 | Compatible paediatric electrodes (multi-pair presentation – see reference 55004) | See reference 55004 |
3.2 Product data
| Manufacturer | GIMA |
|---|---|
| Sales unit | Kit of 2 units (1 pair) |
| Device type | Medical device (medical device) |
| Device class | II B |
| CND | C020401 |
| GMDN | 47055 |
| EAN | 8033695728265 |
3.3 Electrode characteristics
| Electrode type | Paediatric multifunction, disposable, with energy reduction system |
|---|---|
| Indicated population | Children under 8 years or weighing less than 25 kg |
| Energy | Reduction from 200 J (device output) to ≈50 J at the patient |
| Composition | Latex-free |
| Use | Single-use, disposable |
| Manufacture | Italy |
| Packaging | Multilingual: GB, FR, IT, ES, PT, DE, NL, SE, GR, RU |
3.4 Compatibility with defibrillators
| Equipment brand | Compatible models |
|---|---|
| Physio-Control | LIFEPAK 500 AED (presa rosa / pink socket) |
| Physio-Control | LIFEPAK 1000 AED |
| Physio-Control | LIFEPAK CR Plus AED |
| Physio-Control | LIFEPAK Express AED |
4. Equivalences and Cross-References
This electrode (SKU GM33603) is a compatible consumable for Physio-Control/Medtronic LIFEPAK defibrillators with pink socket, not an original factory spare part. The correspondence with the equipment manufacturer’s references and with other brands in the sector is as follows; any comparison between brands should be understood as comparable at category level, not interchangeable 1:1.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| (product manufacturer) | Compatible paediatric electrodes for LIFEPAK (this datasheet) | 33603 | Original reference | SKU Cahnos GM33603; kit of 2 units (1 pair); energy reduction 200 J → ≈50 J |
| Catalogue Cahnos | Multi-pair presentation of the same electrode | 55004 | Same product, multi-pair presentation | Reference cited in the catalogue as see also 55004; indicated for fleet replacement or centres with several devices |
| Stryker / Physio-Control | Infant/Child Reduced Energy Defibrillation Electrodes (original equipment) | 11101-000016 (spare part) / 11101-000017 (kit with carry bag) | Comparable by category (not interchangeable 1:1) | Factory original for LIFEPAK 500 (pink socket), 1000, CR Plus and Express; same paediatric criteria (under 8 years / under 25 kg) and same attenuation (÷4: 200 J → ≈50 J); own labelling, gel and packaging |
| Cahnos | Paediatric limited-energy electrodes for LIFEPAK (catalogue Cahnos) | F7952PL / F7952WPL | Functionally compatible (not interchangeable 1:1) | Same platform of LIFEPAK devices with pink socket and same energy reduction 200 J → ≈50 J; variants with internal / external cable |
| ZOLL Medical | Pedi-Padz II (paediatric electrode) | 8900-0810-01 | Comparable by category (not interchangeable 1:1) | Same paediatric range, but connector and proprietary algorithm of ZOLL AED Plus / AED Pro devices |
| Philips | Infant/Child Reduced-Energy Defibrillator Pads | M3870A | Comparable by category (not interchangeable 1:1) | For Philips HeartStart FR2 / FR2+ AEDs; proprietary connector and energy management |
There is no equivalence table validated by Physio-Control/Stryker that authorises the replacement of original references with third-party pads: the connector, the analysis algorithm and the energy management are proprietary to each platform. Always verify the exact model of the device and the fit of the connector before clinical use.
5. Selection tips and variants of interest
- Confirm the model and socket of the device: this pair of electrodes corresponds to LIFEPAK 500 AED with pink socket, LIFEPAK 1000, LIFEPAK CR Plus and LIFEPAK Express AEDs. Do not use it on devices with a different connector without prior validation from the technical service.
- Verify the reference and expiry date: check on the packaging the code 33603 and the expiry date; do not force the installation of an expired electrode, as the gel may lose conductivity and compromise the effectiveness of the shock.
- Paediatric provision: in centres with a child population always keep a pair of paediatric electrodes with the AED; the energy is automatically reduced when connecting the limited-energy pad, without manual configuration.
- Variants within the Cahnos catalogue: for the same LIFEPAK platform with pink socket, references F7952PL (internal cable) and F7952WPL (external lead-out cable) are available, both with limited energy. For adult patient care, consult reference 33587 / 55048 (SKU GM33587).
- Maintenance: manage stock rotation by expiry and always replace the electrode after use or expiration. For volume orders or tenders, contact the technical-commercial department of Cahnos indicating the exact model and serial number of your devices.





Reviews