Description
1. Commercial Introduction
Keep your Nihon Kohden defibrillator-monitor always ready for resuscitation with this pair of standard adult defibrillator electrodes with external cable (reference Cahnos F7961W). It is the replacement consumable indicated for the equipment of the Cardiolife TEC-2200, TEC-2300 and TEC-5500 series fitted with the JC-765V cable model, the manufacturer’s patch connection reference for emergency environments, ambulances, hospitals and cardio-protected spaces.
It is sold per pair (2 units) in individual heat-sealed packaging and is ready to be integrated into the cardiopulmonary resuscitation protocols of any service that has these professional defibrillators. Available with immediate shipping from Cahnos and specialised technical support for compatibility verification by model and connector.
2. Technical explanation of the equipment and procedure
Multifunction defibrillation electrodes are the interface element between the defibrillator and the patient: through them the equipment analyses the cardiac rhythm, administers the transthoracic shock and allows emergency electrocardiogram monitoring. This pair is indicated for adult patients (over 8 years old or weighing more than 25 kg) and connects to the equipment’s electrode socket via its configuration with external cable model JC-765V: the pouch contains the cable and connector, ready to be plugged into the equipment at the time of care.
The low-impedance conductive adhesive gel ensures homogeneous contact with the skin, low interface resistance and optimal transmission of the shock energy; the inner metal foil distributes the current uniformly and the 1 mm thick medical foam backing adapts to the contours of the adult chest. The recommended placement is anterolateral (sternum-apex position), following the anatomical diagrams printed on the packaging. They are single-use and disposable: do not reuse under any circumstances and replace after each intervention or upon reaching the expiry date printed on the packaging.
3. Technical Specifications
3.1 Product identification
| Reference Cahnos (SKU) | F7961W |
| Product type | Pair of standard adult multifunction defibrillator electrodes, with external cable |
| Compatible equipment brand | Nihon Kohden – Cardiolife TEC-2200 Series, TEC-2300 Series and TEC-5500 Series (proprietary connector) |
| Cable / connection | External cable model JC-765V (plug-in connector included in the pouch; not pre-connected) |
| Patient type | Adult (older than 8 years / more than 25 kg) |
| Presentation | Price per pair (2 units); 1 pair in heat-sealed packaging; 10 pairs per box in the adult range |
3.2 Technical features
| Parameter | Specification |
|---|---|
| Target population | Adult (older than 8 years / more than 25 kg) |
| Cable configuration | External cable JC-765V (plug-in connector included in the pouch; not pre-connected) |
| Total surface (per electrode) | 148 cm² |
| Active surface (per electrode) | 95 cm² |
| Adhesive ring width | 1 cm |
| Supported shocks | Up to 50 shocks (50 to 360 J) |
| Conductive gel | Low-impedance conductive adhesive gel |
| Conductive material | Metal foil |
| Backing material | Medical foam (FOAM) 1 mm thick |
| Connection type | Safety anti-shock connector or clip (depending on model), with external cable |
| ECG monitoring | Up to 24 h |
| Use | Single-use, disposable, non-sterile |
| Latex / phthalates | Latex-free and phthalate-free |
| Primary packaging | 1 pair in heat-sealed polyethylene and aluminium bag, with laser pre-cut and opening notch |
| Shelf life | Approx. 30 months from the date of production; expiry indicated on the packaging |
| Storage | Dry place, between +5 °C and +35 °C; operation between 0 °C and +50 °C |
| Regulatory classification | Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745) |
| Reference standards | ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993-10 |
3.3 Compatible equipment
| Equipment brand | Compatible models | Cable / connection |
|---|---|---|
| Nihon Kohden | Cardiolife TEC-2200 Series | External cable JC-765V |
| Nihon Kohden | Cardiolife TEC-2300 Series | External cable JC-765V |
| Nihon Kohden | Cardiolife TEC-5500 Series | External cable JC-765V |
Technical note: the values for active surface (95 cm²), total area (148 cm²), shocks (50–360 J) and adhesive ring (1 cm) correspond to the standard adult electrode series with external cable of this product family; confirm them with the technical data sheet of the supplied batch and the equipment manual before use in tenders. The JC-765V cable is the adapter used by the TEC-2200, TEC-2300, TEC-5500, TEC-7600, TEC-7700 and TEC-7531 series; the TEC-5600 and TEC-8300 series use the K342B cable (JC-865V). Always verify the correct fit of the connector in the equipment’s electrode socket.
4. Equivalences and Cross-References
The reference F7961W is the Cahnos distribution code for this electrode compatible with Nihon Kohden; it is not an official reference of the equipment manufacturer. The connector and energy management of the Cardiolife TEC defibrillators are proprietary to Nihon Kohden, so equivalences with other brands are comparable only at category level and not interchangeable 1:1. The following cross-references have a code confirmed in the manufacturer’s IFU, official catalogue or manufacturer-authorized technical distributor sheet:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Nihon Kohden | Disposable adult/child/infant pad (original equipment) | P-740K | Comparable by category (not interchangeable 1:1) | Factory original with 1.5 m cable; reference confirmed in the manufacturer’s official IFU and authorised distributors. Covers AED-2100K/2150K/2151K/2152K, AED-3100, EMS-1052 and the TEC-5500, TEC-5600, TEC-7600, TEC-7700 and TEC-8300 series; not verified for the TEC-2200/2300 series with JC-765V cable. Connector and labelling proprietary to Nihon Kohden. |
| Nihon Kohden | Disposable AED electrodes adult/child/infant (original equipment) | P-711 (order code H329) | Comparable by category (not interchangeable 1:1) | Factory original with 1.5 m cable for adult, child and infant; confirmed in the manufacturer’s official IFU and authorised distributors. Aimed at the Cardiolife AED and TEC-8300K families; not verified for the TEC-2200/2300/5500 series with JC-765V cable. |
| Nissha Medical Technologies (HeartSync) | Defibrillation pads compatible with Nihon Kohden TEC-5500, TEC-5600, TEC-7600, TEC-7700 and TEC-8300 | T100AC-NIHONKOHDEN (ref. 6600265H) | Comparable by category (not interchangeable 1:1) | Code confirmed in the manufacturer’s official catalogue: connector comparable to the original Nihon Kohden and 2 m cable inside the packaging (leads-in), radiolucent construction. The catalogued version is adult (total surface about 371 cm² per pair, larger than this series); verify connector, cable (JC-765V / K342B-JC-865V depending on series) and measurements before replacement. |
| AB Medica Group (Lessa) | Adult defibrillation pads for TEC-2200 / TEC-2300 with JC-765V cable | 99.835.66 (TEC-2200) / 99.835.22 (TEC-2300) | Comparable by category (not interchangeable 1:1) | Same functional profile: adult electrode for the TEC-2200/TEC-2300 platform with JC-765V cable. Codes confirmed in the manufacturer-distributor data sheet; connector and discharge protocol proprietary to the device; the public data sheet for the TEC-2300 variant does not confirm the full set of features, so it is not interchangeable 1:1 and is pending official validation by the equipment manufacturer. |
There is no equivalence table validated by the manufacturer (Nihon Kohden) authorising the replacement of the original electrodes with third-party pads: the connector, analysis algorithm and energy management of each defibrillator are proprietary and are not interchangeable 1:1 between brands. Any replacement must be validated against the technical data sheet and IFU of the defibrillator; consult the Cahnos technical department before use in tenders.
5. Selection tips and variants of interest
- Confirm the model and connector of the device: this pair corresponds to the Nihon Kohden Cardiolife TEC-2200, TEC-2300 and TEC-5500 defibrillators with external JC-765V cable. Check that the connector fits the electrode socket before clinical use and, if in doubt, contact the Cahnos technical department stating the model and serial number.
- Do not confuse the adult and paediatric versions: this pair is for patients over 8 years of age or over 25 kg. For the paediatric population in the same connector family, references F7961P (internal cable) and F7961PW (external cable) are available.
- External cable vs internal cable: the external cable configuration leaves the connector accessible for plugging the pair into the device at the precise moment; if you prefer an integrated connection without loose cables, the standard adult version with internal cable is the F7961, and for imaging procedures (radiology, haemodynamics) the radiotransparent version with internal cable is the F7761.
- Storage and expiry: always check the date printed on the packaging and store in a dry place between +5 °C and +35 °C; do not use expired electrodes or electrodes with damaged packaging, as the gel may lose conductivity.
- Plan your replacement stock: as this is a single-use consumable, maintain a minimum stock per defibrillation unit and rotate stock according to the expiry date (FIFO method).
- Volume orders and tenders: contact the Cahnos technical department stating the exact model and required quantities; we will confirm references, expiry dates and commercial terms before finalising the order.