We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Professional Triplex Antigen Test Covid-19 | Influenza A and B | RSV Hightop – Simultaneous Detection of SARS-CoV-2, Influenza A/B and Respiratory Syncytial Virus in 10 Minutes | Box of 20 Kits (TES-H107)

Price on request

Professional-use triplex antigen test for the simultaneous detection of SARS-CoV-2, influenza A/B and RSV in a single nasal or nasopharyngeal sample, with results in 10 minutes. Included in the common EU list of antigen detection tests for COVID-19 diagnostics. It is supplied in a box of 20 kits with triple-reading cassettes, sterile swabs and extraction tubes pre-filled with buffer solution. Clinical data validated against PCR: sensitivity of 95.00% and specificity of 99.75% for SARS-CoV-2; 93.02% and 97.26% for Influenza A/B; and 94.12% and 97.87% for RSV. Ideal for emergency departments, primary care, care homes and seasonal respiratory infection screening campaigns.

International shipping. Import duties and taxes are payable by the recipient.

Reference
TES-H107

Description

1. Commercial Introduction

The antigen test Triplex Covid | Flu A and B | RSV Hightop (ref. TES-H107) is a diagnostic solution for exclusively professional use that covers, in a single test, three of the most seasonally circulating respiratory pathogens: SARS-CoV-2 (COVID-19), Influenza A/B (flu) and respiratory syncytial virus (RSV). Designed for the point of care, this test improves workflow efficiency in hospitals, emergency departments, primary care, private practices, pharmacies and healthcare residences, since with a single sample collection and in just 10 minutes the professional obtains a differential and reliable result, without the need for additional equipment.

2. Technical explanation of the procedure

The device is a rapid diagnostic test (TROD) based on a sandwich-type lateral flow chromatographic immunoassay. Specific antibodies immobilised on the cassette capture the viral antigens present in the sample (SARS-CoV-2 nucleocapsid protein, Influenza A/B nucleoproteins and RSV antigens). After inserting the nasal or nasopharyngeal swab into the pre-filled blood collection tube with buffer solution, the mixture migrates by capillary action along the test strip: the appearance of coloured lines on the triple result reader (COVID, Flu A/B and RSV) indicates the presence of the corresponding pathogen, while the control line (C) validates the correct functioning of the assay. The complete procedure is carried out in a few steps: sample collection, extraction in the buffer, addition to the cassette well and reading of the result within a maximum of 10 minutes.

3. Technical Specifications

General characteristics

Parameter Specification
Detection method Lateral flow chromatographic immunoassay (TROD rapid antigen test)
Pathogens detected SARS-CoV-2 (COVID-19), Influenza A/B (flu) and Respiratory Syncytial Virus (RSV)
Sample type Nasal or nasopharyngeal swab
Reading time Maximum 10 minutes
Format Test cassette with triple result reader
Reference method PCR
Certification Included in the EU common list of antigen detection tests for the diagnosis of COVID-19
Presentation Box of 20 kits · 48 boxes per carton (960 kits per carton)

Clinical data (validated against PCR)

Pathogen Clinical sensitivity Clinical specificity
SARS-CoV-2 95.00 % 99.75 %
Influenza A/B 93.02 % 97.26 %
RSV 94.12 % 97.87 %

Contents of each box (20 kits)

Materials included Quantity
Test cassettes (triple result reader) 20
Sterile swabs 20
Pre-filled blood collection tubes with buffer solution 20
Workstation 1
Instruction manual 1

Packaging and logistics

Item Value
Kits per box 20 kits
Boxes per carton 48 boxes
Kits per carton 960 kits

4. Equivalences and Cross-References

The TES-H107 triplex panel (Hightop) is part of the Cahnos rapid respiratory test family and is functionally equivalent to other combined antigen tests in the same catalogue. Notable references with equivalent or extended coverage include: IRT-545 / IRT-545-1 (4-5 in 1 panel Covid | Flu A and B | RSV | Adenovirus), MF-71-1 (multiplex self-test Covid | Flu A and B | RSV, 12 min reading), IU-COVTESGVRS-1 and ISIR-9334 (combined SARS-CoV-2 / Flu A-B / RSV antigen kits). As reduced-spectrum alternatives (Covid + flu A/B) there are IU-COVTESG-8 (Safecare), COIF-522 / COIF-522C (SEJOY, box of 25 units) and ICIC-525. The choice of one reference or another will depend on the required viral coverage, the volume per pack and the scope of application (professional use, self-test or mass screening).

5. Selection tips and variants of interest

  • Triple coverage in a single sample: this test simultaneously differentiates COVID-19, flu A/B and RSV, ideal for the differential diagnosis of winter respiratory infections.
  • High-volume centres: the presentation in a box of 20 kits with 960 kits per carton optimises the cost per determination, storage and replenishment during peak season.
  • Sampling versatility: accepts nasal or nasopharyngeal swab, adapting to the centre’s protocol and patient tolerance (especially relevant in paediatrics and geriatrics).
  • Clinical recommendation: confirm positive results by PCR before making therapeutic decisions, especially in at-risk populations.
  • Catalogue alternatives: if you also need to cover adenovirus, consider the 5-in-1 panel (IRT-545-1); if RSV is not a priority, the Covid + Flu A/B panels (COIF-522, IU-COVTESG-8) may offer a more competitive cost per test.

Additional information

Method

Lateral flow chromatographic immunoassay (TROD rapid antigen test)

Pathogens detected

SARS-CoV-2 (COVID-19), Influenza A/B, Respiratory Syncytial Virus (RSV)

Sample type

Nasal or nasopharyngeal swab

Result time

Maximum 10 minutes

Reference method

PCR

Format

Test cassette with triple result reader

Clinical sensitivity

95.00% (SARS-CoV-2) · 93.02% (Influenza A/B) · 94.12% (RSV)

Clinical specificity

99.75% (SARS-CoV-2) · 97.26% (Influenza A/B) · 97.87% (RSV)

Presentation

Box of 20 kits · 48 boxes per carton (960 kits per carton)

Box contents

20 cassettes, 20 sterile swabs, 20 pre-filled blood collection tubes, 1 workstation, 1 instruction manual

Certifications

EU common list of antigen detection tests for COVID-19

Use

Professional (exclusive)

Reviews

There are no reviews yet.

Be the first to review “Professional Triplex Antigen Test Covid-19 | Influenza A and B | RSV Hightop – Simultaneous Detection of SARS-CoV-2, Influenza A/B and Respiratory Syncytial Virus in 10 Minutes | Box of 20 Kits (TES-H107)”

Your email address will not be published. Required fields are marked *