Description
The UROSID2000 Urine Bag (Ref. 690212-N) is the reference solution for continuous urinary drainage in patients requiring safe, hygienic and reliable collection of urine. With a capacity of 2 litres, 120 cm tube and vertical design without needle, this product combines comfort, safety and versatility in both hospital and home settings.
Operation and clinical application: this drainage bag connects to a urinary catheter (Foley type) to collect urine passively and continuously by gravity. The vertical design optimises downward flow, reducing the risk of reflux and obstructions, and facilitates attachment to the bed or patient support. As it contains no additives (s.a.) in its composition, it minimises the risk of interference or reactions on contact with the drained fluid, making it especially suitable for prolonged treatments, postoperative care and patients with urinary retention or reduced mobility.
Technical specifications:
| Characteristic | Specification |
|---|---|
| Product type | Urine bag / urinary drainage catheter UROSID2000 |
| Reference | 690212-N |
| Volume | 2 litres (2000 ml) |
| Tube length | 120 cm |
| Design | Vertical |
| Connection type | Without needle (without drainage) |
| Composition | Without additives (s.a.) |
| Application | Urinary drainage in hospital, clinic and home |
| Presentation | Box of 25 units |
Equivalences and cross-references: the UROSID2000 range from Cahnos maintains the same 2-litre volume with different configurations to suit positioning and clinical preference. Reference 690212 corresponds to the same 120 cm vertical version with needle. Alternatives from the same family include: 690210-N (120 cm horizontal without needle), 690090-N (90 cm horizontal without needle) and 690092-N (90 cm vertical without needle). For greater autonomy needs, the UROSID20 series (690190, 690120, 690120-H) completes the range of drainage bags in the same category.
Selection advice and variants: choose the 120 cm vertical design when the patient remains bedridden and a longer tube length is required to facilitate mobility and handling. For lower positions or patients with greater ambulation, the 90 cm variants or horizontal designs may be more suitable. If the protocol requires sample collection or specific fixation systems, consider the versions with needle or the UROSID range systems. Always check the compatibility of the connector with the patient’s catheter and the sterility conditions required by the centre’s protocol.





Reviews
There are no reviews yet.