Description
Precise and segmented control of diuresis
The M2 triple-compartment (3C) urine measurement system is the professional solution your department needs for rigorous control of urinary output in critical patients. With a 2,600 ml collection bag and 150 cm connection tube, this reference (690312) offers the flexibility and precision required by intensive care units, operating theatres and postoperative areas, ensuring continuous and reliable monitoring of fluid balance.
Technical operation of the M2 urinometer
The M2 urinometer is integrated into a closed sterile drainage circuit connected to the patient’s urinary catheter (Foley-type catheter). Urine flows down the 150 cm tube to the drip chamber, which incorporates a non-return valve to prevent reflux towards the patient. The flow is then distributed among the three measurement compartments, whose scale allows accurate readings even with very small volumes. Once the measurement has been recorded, the system is drained in a controlled manner into the 2,600 ml collection bag, fitted with a transverse emptying valve and a microfilter with a hydrophobic coating, impermeable to bacteria and liquids. The set is supplied sterile by ethylene oxide (EO), is manufactured without natural rubber latex and is single-use.
Technical specifications
| Model / family | M2 – triple-compartment urinometer (UROSID®) |
| Reference | 690312 |
| Compartments | 3 (3C) |
| Collection bag capacity | 2,600 ml |
| Urine meter scale | 500 ml |
| Reading graduation | From 5 ml |
| Tube length | 150 cm |
| Sample collection port | With needle |
| Drip chamber | With integrated non-return valve |
| Emptying system | Transverse valve |
| Bag ventilation | Hydrophobic microfilter, impermeable to bacteria and liquids |
| Sterility | Sterilised by ethylene oxide (EO) |
| Latex | Free of natural rubber latex |
| Type of use | Single-use (disposable) |
| Presentation | Box of 10 units |
The triple-compartment design allows urinary volume to be recorded at intervals, facilitating early detection of diuresis abnormalities and real-time clinical decision-making.
Equivalences and cross-references
This system corresponds to the triple-compartment urine meter UROSID® M2 from Medline/Conod. Reference 690312 (150 cm tube) belongs to the 6903×2-x family of M2 urinometers, which includes the 690322 variant with a 120 cm tube. Within the same range of closed urinometers are the single-chamber M3 model (refs. 690313 and 690323) and the double-chamber M1 model (refs. 690311 and 690321). As an alternative from other manufacturers, the closed systems from Rüsch/Teleflex (refs. 673081-000000 and 673082-000000, with a 500 ml urinometer and a 2,000 ml collector) offer comparable performance for diuresis monitoring. To connect irrigation solutions or TUR collection systems, it is recommended to always use a triple-lumen Foley catheter.
Selection tips and variants of interest
- Choose the M2 triple-compartment model when you need segmented interval monitoring of urinary output, especially in critical patients, ICU and major burn patients, where every millilitre counts for fluid balance.
- If you need a simpler and more direct measurement of accumulated volume, consider the single-chamber M3 model (ref. 690323, 120 cm tube). For an intermediate separation, the double-chamber M1 model (refs. 690311 and 690321) is a balanced option.
- The tube length should be chosen according to the distance between the patient and the bag support: 120 cm (ref. 690322) for bedside placement and 150 cm (this product) for greater versatility.
- All systems are supplied in boxes of 10 units and are compatible with standard clinical protocols for fluid balance control.






Reviews