Description
The M1 double-compartment (2C) urinometer is the reference solution for rigorous fluid balance control in demanding hospital settings. With a 2,600 ml collection bag and a 150 cm flexible tube, this system enables continuous and safe monitoring of the patient’s urine output, helping nursing staff to detect early alterations in diuresis in critical, postoperative and patients under intensive monitoring. Its double-chamber design separates the measured volume from the accumulated volume, ensuring reliable real-time urine output readings without the need for frequent manipulation.
Technical operation of the system
The M1 urinometer integrates into a closed, sterile urinary drainage circuit that connects to the patient’s bladder catheter (Foley-type catheter) via a 150 cm flexible tube, offering versatile and comfortable placement either at the bedside or on infusion stands. Urine flows down through the drip chamber, fitted with a non-return valve that prevents reflux towards the patient, and collects in the graduated 500 ml measuring chamber, with graduations from 5 ml, allowing precise quantification of even very small volumes. The double-compartment (2C) design separates the measured volume from the accumulated volume: once the reading is recorded, the contents are poured in a controlled manner into the 2,600 ml collection bag via the transverse drainage valve. The assembly incorporates a microfilter with a hydrophobic coating, impermeable to bacteria and liquids, which regulates bag ventilation and significantly reduces the risk of nosocomial infections associated with catheterisation. It is a sterile product by ethylene oxide (EO), single-use and free from natural rubber latex.
Technical specifications
| Characteristic | Value |
|---|---|
| Model / family | M1 – double-compartment urinometer (UROSID®) |
| Reference | 690311 |
| Compartments | 2 (2C) |
| Collection bag capacity | 2,600 ml |
| Urine meter scale | 500 ml |
| Reading graduation | From 5 ml |
| Tube length | 150 cm |
| Sample collection port | With needle |
| Drip chamber | With integrated non-return valve |
| Emptying system | Transverse valve |
| Bag ventilation | Hydrophobic microfilter, impermeable to bacteria and liquids |
| Sterility | Sterilised by ethylene oxide (EO) |
| Latex | Free of natural rubber latex |
| Type of use | Single-use (disposable) |
| Presentation | Box of 10 units |
The double-compartment design allows urinary volume to be recorded by separating the measuring chamber from the collection bag, facilitating early detection of diuresis alterations and real-time clinical decision-making.
Equivalences and cross-references
This system corresponds to the double-chamber urine meter UROSID® M1 from the international urological family. Reference 690311 (150 cm tube) is the long-circuit variant of the M1 model, which is also supplied with a 120 cm tube under reference 690321. Within the same range of closed urinometers are the triple-compartment model M2 (refs. 690312 and 690322) and the single-chamber model M3 (refs. 690313, 690313-N and 690323). As an alternative from other manufacturers, the closed urinometer systems from Rüsch/Teleflex (refs. 673081-000000 and 673082-000000, with a 500 ml urinometer and a 2,000 ml collector) offer comparable performance for diuresis monitoring. Contact our commercial team to confirm equivalences according to your tender or internal protocol.
Selection tips and variants of interest
Choose the double-chamber M1 (2C) model when you need to separate the measured volume from the accumulated volume, a balanced solution between the simplicity of the single-chamber 1C and the interval segmentation of the triple-compartment 3C. If you require a shorter circuit for bedside placement, ref. 690321 with 120 cm is the appropriate option; for greater placement versatility, consider this 150 cm variant (ref. 690311). For advanced interval monitoring, consider the triple-compartment M2 (refs. 690322 and 690312), and for direct, economical control of accumulated volume, the single-chamber M3 model (refs. 690313 and 690323). All systems are supplied in boxes of 10 units and are compatible with standard clinical protocols for fluid balance control. For replacement bags in compatible systems, consult the urinometer replacement bag (ref. 1044003).






Reviews
There are no reviews yet.