Description
Silicone Foley Catheter Tiemann Type CH12
The Silicone Foley Catheter Tiemann Type in CH12 is the reference solution in urology for bladder drainage when the patient’s anatomy presents difficulties: enlarged prostate, urethral strictures or tortuous passages. Its two-way design, its 5-10 ml fixation balloon and its manufacture in biocompatible medical silicone make it a safe, comfortable and durable choice for temporary or prolonged catheterisation, both in hospitals and in clinics and urology practices.
Medical silicone guarantees a smooth, flexible surface that is completely latex-free, which reduces urethral irritation, the risk of encrustation and allergic reactions. The result is greater comfort for the patient and a lower workload for the nursing team, with less frequent changes in long-term treatments.
Technical explanation and procedure
The Foley catheter is a bladder catheter that is inserted via the urethra into the bladder. In this two-way version, the main lumen allows continuous drainage of urine into the collection bag, while the secondary lumen is used to inflate the distal balloon with 5-10 ml of saline solution or sterile water, fixing the catheter in position and preventing accidental dislodgement.
The Tiemann tip, characterised by its curvature and terminal olive, is the great advantage of this model: it allows smooth passage through the prostatic urethra in patients with benign prostatic hyperplasia (BPH), urethral stricture, sphincter spasm or any obstruction that makes catheterisation with straight-tip catheters difficult. It is a single-use, sterile device that must be used with aseptic technique and a closed drainage system to minimise the risk of urinary tract infection (UTI). The CH12 size (12 Fr, approximately 4 mm external diameter) is indicated when less urethral trauma is required or when there is marked narrowing.
Technical specifications
| Type | Tiemann-type Foley catheter, curved end with olive tip |
| Material | Transparent medical silicone, latex-free |
| Gauge | CH 12 (12 Fr, external diameter approx. 4.0 mm) |
| Number of ways | 2 (drainage and balloon) |
| Cuff | 5-10 ml, with non-return valve |
| Length | 40 cm |
| Radiopaque line | Yes, radiopaque throughout the catheter body |
| Sterilisation | Sterile, single-use |
| Presentation | Box of 10 units |
| Intended use | Transurethral bladder drainage, temporary or prolonged, in difficult anatomy |
The Tiemann silicone range with 5-10 ml balloon is available in several sizes to suit each patient:
| Gauge | Reference | Cuff | Length |
| CH 12 | 653012 | 5-10 ml | 40 cm |
| CH 14 | 653014 | 5-10 ml | 40 cm |
| CH 16 | 653016 | 5-10 ml | 40 cm |
| CH 18 | 653018 | 5-10 ml | 40 cm |
| CH 20 | 653020 | 5-10 ml | 40 cm |
Equivalences and cross-references
This two-way silicone Foley catheter Tiemann type with 5-10 ml balloon in size CH 12 is equivalent, by specifications and clinical use, to the following common market references:
- Teleflex / Rüsch: series 186505 (Foley catheter Tiemann in silicone, sizes CH 12-24, balloon 5-15 ml, length approx. 40 cm) and reference 23.000.20.212 in size CH 12.
- Reference 097.12: two-way silicone Tiemann catheter, radiopaque line and connector with non-return valve, size 12 (Zhanjiang Star type range).
- UROSID® range (Medline): 10 ml silicone Foley catheters with Tiemann tip, same indications for bladder drainage in male patients.
- Dahlhausen range: Tiemann catheter with silicone balloon, 100% silicone, curved tip for prostatic obstruction.
All of them share the same principle: biocompatible silicone, curved olive tip, double lumen and low-volume balloon for bladder fixation. The direct correspondence between the Charrière scale (CH) and the French scale (Fr) makes this reference interchangeable with any silicone Foley Tiemann catheter CH 12 from other approved suppliers, provided that balloon, length and material are verified.
Selection tips and variants of interest
- Size selection: CH 12 is recommended in patients with marked narrowing or when minimising urethral trauma is desired; for wider flow drainage, consider CH 14 (ref. 653014) or CH 16 to CH 20 (refs. 653016, 653018, 653020).
- Catheterisation duration: silicone is the recommended material for prolonged stays (up to 12 weeks per protocol) due to its low encrustation and high tolerance; for short stays, a silicone-coated latex catheter may be considered.
- Coated variant: if the priority is to prevent catheter-associated urinary tract infections, consider the silicone Foley catheter with syringe and Glyco-SID coating in size CH 12 (ref. 642012-P).
- Correct balloon use: inflate with 5-10 ml of sterile solution respecting the indicated maximum volume to avoid bladder injury, and always deflate before removal.
- Complementary accessories: to complete the closed system we recommend a urinary drainage bag, catheter fixation device, sterile urological lubricant and catheterisation kit with aseptic technique.





Reviews