We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Two-way Silicone Foley Catheter CH12 (12 Fr) with Glyco-SID Syringe | 10 ml Balloon | 40 cm Length | Adult Urinary Catheter | Latex-free | Ref. 642012-P

16,56 €

Silicone Foley catheter CH12 (12 Fr) two-way with Glyco-SID syringe for inflating the 10 ml balloon and 40 cm length. Made entirely of biocompatible medical silicone and latex-free, it incorporates a lubricant coating that facilitates smooth and atraumatic insertion, reduces urethral friction and minimises the risk of irritation and encrustation during indwelling. Includes inflation syringe and non-return valve for stable and secure fixation. Indicated for temporary or prolonged urinary catheterisation in adult patients, postoperative bladder drainage and long-term medical treatments. Ideal for hospitals, urological clinics, nursing homes and social-health centres. Reference 642012-P.

International shipping. Import duties and taxes are payable by the recipient.

Reference
642012-P

Description

The Silicone Foley Catheter with Glyco-SID in CH12 calibre, 10 ml balloon and 40 cm length is the reference solution for safe and prolonged bladder drainage in adult patients. Its entire body of 100% biocompatible medical silicone, free from latex, guarantees high tissue tolerance, reduces urethral irritation and allows prolonged stays with total comfort and clinical safety. An essential reference for hospitals, urological clinics, nursing homes and social-health centres seeking consistent quality, traceability and patient comfort.

Technical description of the device

The Foley catheter is a bladder catheter inserted via the urethra into the bladder for continuous urine drainage. This two-way version integrates two independent channels in a single silicone body: a main drainage lumen through which urine flows to the collection bag and a secondary lumen connected to the distal fixation balloon. The 10 ml balloon is inflated with sterile water or physiological saline using the included pre-filled syringe and its non-return valve, fixing the catheter in position and preventing accidental removal.

The Glyco-SID lubricant coating reduces friction during insertion and indwelling, promoting smooth and atraumatic catheterisation, reducing patient discomfort and the risk of urethral mucosal injury, as well as catheter-associated urinary tract infections (CAUTI). The CH12 calibre (12 Fr, approximate external diameter 4.0 mm) offers efficient drainage with minimal urethral trauma, being especially suitable for patients with strictures or when maximum tolerance is sought.

Technical specifications

Characteristic Specification
Type Two-way Foley catheter, Nelaton tip
Material Medical silicone with Glyco-SID coating (latex-free)
Gauge CH12 (12 Fr, external diameter approx. 4.0 mm)
Number of ways 2 (drainage and balloon)
Balloon capacity 10 ml, with non-return valve and included syringe
Length 40 cm
Coating Glyco-SID (reduces the risk of infections)
Use Urinary catheterisation in adults, temporary or prolonged, and postoperative drainage
Sterilisation Sterile, single-use
Reference 642012-P

This catheter is part of a complete range of sizes with Glyco-SID coating to suit each patient:

Gauge Reference Cuff Length
CH12 642012-P 10 ml 40 cm
CH14 642014-P 10 ml 40 cm
CH16 642016-P 10 ml 40 cm
CH18 642018-P 10 ml 40 cm
CH20 642020-P 10 ml 40 cm
CH22 0691086 10 ml 40 cm
CH24 642024-P 10 ml 40 cm

Equivalences and cross-references

By specifications and clinical use, this two-way silicone Foley catheter with 10 ml balloon in CH12 calibre is equivalent to the usual references of international silicone balloon ranges, such as the Rüsch/Teleflex family of urinary drainage (silicone series 186505, sizes CH12-24, balloon 5-15 ml, approximate length 40 cm) and the UROSID® ranges from Medline of 10 ml silicone Foley catheters with Glyco-SID syringe. The direct correspondence between the Charrière (CH) scale and the French (Fr) scale allows this reference to be interchanged with any CH12 silicone Foley catheter from other approved suppliers, provided that balloon, length and material are verified.

Selection tips and variants of interest

The CH12 calibre is the recommended option when seeking to minimise urethral trauma or in patients with marked stricture. Silicone is the material of choice for prolonged stays due to its low encrustation and high tissue tolerance. If a higher drainage flow rate is required, consult the larger sizes of the same Glyco-SID range: CH14 (642014-P), CH16 (642016-P), CH18 (642018-P), CH20 (642020-P), CH22 (0691086) and CH24 (642024-P). For catheterisation with difficult anatomy (enlarged prostate or tortuous tracts), consider the Tiemann-type silicone Foley catheter (refs. 6530xx). Always inflate the balloon with the indicated volume (10 ml) and deflate before removal. To complete the closed system, a urinary drainage bag, catheter fixation device, sterile urological lubricant and catheterisation kit with aseptic technique are recommended. For volume orders intended for hospitals and purchasing centres, please consult our technical-commercial team.

Additional information

Product type

Two-way Foley catheter, Nelaton tip

Material

Medical silicone, 100% biocompatible, latex-free

Gauge

CH12 (12 Fr, external diameter approx. 4.0 mm)

Number of ways

2 (drainage and balloon)

Balloon capacity

10 ml, with non-return valve and included syringe

Coating

Glyco-SID (lubricated surface)

Sterilisation

Sterile, single-use

Presentation

Unit with inflation syringe

Intended use

Urinary catheterisation in adults, temporary or prolonged, and postoperative drainage

Reference

642012-P

Longitud

40 cm

Reviews

There are no reviews yet.

Be the first to review “Two-way Silicone Foley Catheter CH12 (12 Fr) with Glyco-SID Syringe | 10 ml Balloon | 40 cm Length | Adult Urinary Catheter | Latex-free | Ref. 642012-P”

Your email address will not be published. Required fields are marked *