Description
The Silicone Foley Catheter with Glyco-SID in CH12 calibre, 10 ml balloon and 40 cm length is the reference solution for safe and prolonged bladder drainage in adult patients. Its entire body of 100% biocompatible medical silicone, free from latex, guarantees high tissue tolerance, reduces urethral irritation and allows prolonged stays with total comfort and clinical safety. An essential reference for hospitals, urological clinics, nursing homes and social-health centres seeking consistent quality, traceability and patient comfort.
Technical description of the device
The Foley catheter is a bladder catheter inserted via the urethra into the bladder for continuous urine drainage. This two-way version integrates two independent channels in a single silicone body: a main drainage lumen through which urine flows to the collection bag and a secondary lumen connected to the distal fixation balloon. The 10 ml balloon is inflated with sterile water or physiological saline using the included pre-filled syringe and its non-return valve, fixing the catheter in position and preventing accidental removal.
The Glyco-SID lubricant coating reduces friction during insertion and indwelling, promoting smooth and atraumatic catheterisation, reducing patient discomfort and the risk of urethral mucosal injury, as well as catheter-associated urinary tract infections (CAUTI). The CH12 calibre (12 Fr, approximate external diameter 4.0 mm) offers efficient drainage with minimal urethral trauma, being especially suitable for patients with strictures or when maximum tolerance is sought.
Technical specifications
| Characteristic | Specification |
| Type | Two-way Foley catheter, Nelaton tip |
| Material | Medical silicone with Glyco-SID coating (latex-free) |
| Gauge | CH12 (12 Fr, external diameter approx. 4.0 mm) |
| Number of ways | 2 (drainage and balloon) |
| Balloon capacity | 10 ml, with non-return valve and included syringe |
| Length | 40 cm |
| Coating | Glyco-SID (reduces the risk of infections) |
| Use | Urinary catheterisation in adults, temporary or prolonged, and postoperative drainage |
| Sterilisation | Sterile, single-use |
| Reference | 642012-P |
This catheter is part of a complete range of sizes with Glyco-SID coating to suit each patient:
| Gauge | Reference | Cuff | Length |
| CH12 | 642012-P | 10 ml | 40 cm |
| CH14 | 642014-P | 10 ml | 40 cm |
| CH16 | 642016-P | 10 ml | 40 cm |
| CH18 | 642018-P | 10 ml | 40 cm |
| CH20 | 642020-P | 10 ml | 40 cm |
| CH22 | 0691086 | 10 ml | 40 cm |
| CH24 | 642024-P | 10 ml | 40 cm |
Equivalences and cross-references
By specifications and clinical use, this two-way silicone Foley catheter with 10 ml balloon in CH12 calibre is equivalent to the usual references of international silicone balloon ranges, such as the Rüsch/Teleflex family of urinary drainage (silicone series 186505, sizes CH12-24, balloon 5-15 ml, approximate length 40 cm) and the UROSID® ranges from Medline of 10 ml silicone Foley catheters with Glyco-SID syringe. The direct correspondence between the Charrière (CH) scale and the French (Fr) scale allows this reference to be interchanged with any CH12 silicone Foley catheter from other approved suppliers, provided that balloon, length and material are verified.
Selection tips and variants of interest
The CH12 calibre is the recommended option when seeking to minimise urethral trauma or in patients with marked stricture. Silicone is the material of choice for prolonged stays due to its low encrustation and high tissue tolerance. If a higher drainage flow rate is required, consult the larger sizes of the same Glyco-SID range: CH14 (642014-P), CH16 (642016-P), CH18 (642018-P), CH20 (642020-P), CH22 (0691086) and CH24 (642024-P). For catheterisation with difficult anatomy (enlarged prostate or tortuous tracts), consider the Tiemann-type silicone Foley catheter (refs. 6530xx). Always inflate the balloon with the indicated volume (10 ml) and deflate before removal. To complete the closed system, a urinary drainage bag, catheter fixation device, sterile urological lubricant and catheterisation kit with aseptic technique are recommended. For volume orders intended for hospitals and purchasing centres, please consult our technical-commercial team.