Description
1. Introduction
The two-way silicone-coated latex Foley catheter with Nelaton tip, CH 26 gauge and 30 ml balloon (ref. 663026), is a single-use retention urethral catheter manufactured from medical-grade latex with a silicone coating. It is indicated for effective, controlled urinary drainage in adult patients in urology, hospitalisation, surgery, intensive care and post-surgical care departments. Its excellent value for money makes it a reliable and economical solution for hospitals, clinics, social and healthcare centres and healthcare professionals requiring a constant, approved supply.
2. Technical explanation of the device
The Foley catheter is a retention urinary catheter inserted through the urethra into the bladder. This two-way version integrates two independent channels in a single body: a main drainage channel through which urine flows into the collection bag and a secondary inflation channel connected to the retention balloon. Once the catheter is placed, the balloon is filled with sterile water or physiological saline (30 ml), anchoring the catheter inside the bladder and preventing accidental displacement during treatment or postoperative recovery.
The straight Nelaton tip, with lateral drainage holes, facilitates linear, atraumatic insertion, while the silicone coating on the latex reduces friction on the urethral mucosa, minimises the risk of irritation and encrustation and improves tolerance in short- and medium-term catheterisation. The CH 26 (26 Fr) gauge offers a very wide drainage flow rate, ideal for the adult patient when a generous evacuation flow is required, such as in haematuria, urine with sediment or high-flow postoperative drainage.
3. Technical Specifications
| Catheter type | Straight two-way Foley catheter with Nelaton tip |
| Number of ways | 2 (urinary drainage + balloon inflation) |
| Material | Medical-grade latex with silicone coating |
| Gauge | CH 26 (26 Fr / Charrière-French scale) |
| Balloon capacity | 30 ml |
| Length | 40 cm |
| Distal end | Straight Nelaton tip, with lateral drainage eyes |
| Connection | Valve compatible with Luer-type syringe; connector for urine collection bag |
| Intended use | Continuous and post-surgical bladder urinary drainage in adults |
| Sterility | Sterile, single-use, individually packaged |
| Presentation | Box of 10 units |
| Reference | 663026 |
Range of gauges in the two-way Nelaton series with 30 ml balloon (length 40 cm):
| Reference | Gauge | Cuff | Ways |
| 663012 | CH 12 | 30 ml | 2 |
| 663014 | CH 14 | 30 ml | 2 |
| 663016 | CH 16 | 30 ml | 2 |
| 663018 | CH 18 | 30 ml | 2 |
| 663020 | CH 20 | 30 ml | 2 |
| 663022 | CH 22 | 30 ml | 2 |
| 663024 | CH 24 | 30 ml | 2 |
| 663026 | CH 26 | 30 ml | 2 |
4. Equivalences and Cross-References
By specifications (CH 26 gauge, 30 ml balloon, two-way, Nelaton tip and silicone-coated latex), this catheter is comparable and interchangeable with 26 Fr silicone-coated latex Foley catheters from manufacturers such as Rüsch/Teleflex, Bard (BD group), Coloplast or B. Braun, without the need to modify the insertion protocol or connection accessories. The Charrière (CH) scale is directly equivalent to the French (Fr) scale, so the CH 26 gauge is interchangeable, always verifying balloon, length and material.
Within the Cahnos catalogue, the same two-way configuration with a 5-10 ml balloon corresponds to the 6620xx series (CH 26 equivalent: ref. 662026); the version with Tiemann tip and 30 ml balloon corresponds to the 6660xx series, recommended for complex prostatic anatomy or urethral stricture; and if simultaneous bladder irrigation is required, the three-way version may be considered. For patients with latex allergy or medium- and long-term catheterisation, the 100% silicone range is recommended, which covers the full range of bladder drainage cases with a single supplier.
5. Selection tips and variants of interest
Always select the smallest gauge that ensures adequate drainage under clinical judgement: the intermediate gauges CH 14, CH 16 and CH 18 are the most common in standard adult catheterisation, while CH 26 is reserved for very high flow requirements, urine with sediment, haematuria or high-flow postoperative drainage. The 30 ml balloon offers a larger fixation surface and a lower risk of accidental expulsion than 5-10 ml balloons, and is recommended for urinary retention requiring assisted bladder emptying.
Always inflate the balloon with the recommended volume of sterile water or physiological saline, use a compatible water-soluble lubricant and aseptic technique, and connect the collection bag with a closed system to minimise the risk of catheter-associated urinary tract infection. Check the integrity of the sterile packaging before each use. To complete the drainage system, we recommend combining this catheter with our urine collection bags. Contact our technical-commercial team for special volume purchase conditions for hospitals and purchasing groups.





Reviews