Description
1. Commercial Introduction
Ensure hygienic, discreet and safe stool management for bedridden, immobilised or incontinent patients with the DIARFLEX® replacement collection bags with activated carbon filter, the original reference from the German manufacturer Primed Halberstadt Medizintechnik (Ref. 20865). Each kit includes two 1500 ml bags made with superabsorbent polymer, specifically designed for the DIARFLEX® ADVANCED stool drainage system. A replacement solution intended for hospitals, clinics and social healthcare centres seeking continuity of care with the best value for money in B2B volume purchasing.
2. Technical explanation of the equipment and procedure
The DIARFLEX® system is a closed stool management system that hygienically channels potentially infectious liquid and semi-liquid stool from a biocompatible silicone rectal catheter with a low-pressure balloon to a disposable collection bag. The replacement bag attaches to the end of the catheter hose via a rotary closure that ensures a firm and leak-proof connection, preventing leaks and minimising healthcare personnel contact with biological material. The interior incorporates a superabsorbent polymer that gelifies liquids and facilitates disposal of the contents, while the integrated activated carbon filter neutralises unpleasant odours during continuous use. In the ADVANCED version, the hose sealing plug allows the bag to be replaced while temporarily sealed, making replacement quick and safe at the bedside. It is a non-sterile, latex-free and DEHP-free, single-use product, with a shelf life of up to 5 years from manufacture.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Manufacturer reference | 20865 (Primed Halberstadt Medizintechnik GmbH) |
| Capacity | 1500 ml |
| Material | Superabsorbent polymer for liquid absorption |
| Filter | Integrated activated carbon filter (inhibits odours) |
| Connection | Rotary closure for easy connection to the end of the hose |
| Safety | Firmly attached closure cap to prevent leaks |
| Units per kit | 2 replacement bags |
| Compatibility | DIARFLEX® and DIARFLEX® ADVANCED systems |
| Sterility | Non-sterile, disposable single-use product |
| Composition | Latex-free and DEHP-free |
| Storage | Product usable up to 5 years (non-sterile) |
| Presentation / order | Kit of 2 bags; minimum order of 10 kits |
4. Equivalences and Cross-References
The reference 20865 is confirmed in the official catalogue of the manufacturer Primed Halberstadt Medizintechnik GmbH as ‘DIARFLEX® Replacement Bags with active carbon filter’ in a packaging unit of 2 pieces, matching exactly the article marketed. Within the same manufacturer family, the following references are verified, which should not be treated as interchangeable 1:1:
- Ref. 20128 – DIARFLEX® standard replacement bags (3 units), same 1500 ml capacity and same rotary closure but without activated carbon filter: comparable by category, not an exact equivalent if odour control is required (Cahnos Ref. 20128).
- Ref. 20762 – DIARFLEX® ADVANCED complete system (1 set with catheter, bag with filter, 2 replacements, Luer lock syringe and accessories): different product, included in the kit (Cahnos Ref. 20762).
- Ref. 20775 – DIARFLEX® adhesive faecal collector 1000 ml with hydrocolloid dressing: same brand but different function and fitting (Cahnos Ref. 20775).
The rotary closure connection is a proprietary system of the manufacturer, therefore there is no equivalence table validated by the manufacturer with bags from other brands (e.g. faecal management systems from other suppliers); consult with the technical department of Cahnos before using this product in a tender that requires interchangeability with other systems.
5. Selection tips and variants of interest
Select this kit of 2 bags with activated carbon filter (Ref. 20865) when working with the DIARFLEX® ADVANCED system and prioritising odour neutralisation and leak-tightness during replacement. If your protocol does not require a filter, the Ref. 20128 (3 standard bags) may be more cost-effective per unit; if you need to renew the complete system, the Ref. 20762 includes catheter, bag and replacements; and for patients with high mobility or intermittent use, consider the faecal collector Ref. 20775. Remember to respect the minimum order of 10 kits, check the integrity of the packaging before each use and manage the product as healthcare waste in accordance with the centre’s regulations. For B2B volume conditions, continuous supply contracts or group purchasing budgets, contact the technical-commercial team of Cahnos.





Reviews