Description
1. Introduction
The two-way silicone-coated latex Foley catheter with Nelaton tip, CH 16 calibre and 30 ml balloon (ref. 663016) is a single-use retention urethral catheter, manufactured from medical-grade latex with a silicone coating. It is indicated for effective and controlled urinary drainage in adult patients in urology, hospitalisation, surgery, intensive care and post-surgical care services. Its excellent value for money makes it a reliable and economical solution for hospitals, clinics, social health centres and healthcare professionals who need a constant and approved supply.
2. Technical explanation of the device
The Foley catheter is a retention urinary catheter that is inserted through the urethra into the bladder. This two-way version integrates two independent channels in a single body: a main drainage channel through which urine flows into the collection bag and a secondary inflation channel connected to the retention balloon. Once the catheter is placed, the balloon is filled with sterile water or physiological saline (30 ml), anchoring the catheter inside the bladder and preventing accidental displacement during treatment or postoperative recovery.
The straight Nelaton-type tip, with lateral drainage holes, facilitates linear and atraumatic insertion, while the silicone coating over the latex reduces friction on the urethral mucosa, minimises the risk of irritation and encrustation and improves tolerance in short- and medium-term catheterisations. The CH 16 (16 Fr) calibre is one of the most commonly used in standard adult catheterisation, with a drainage flow rate suitable for most common clinical indications.
3. Technical Specifications
| Catheter type | Straight two-way Foley catheter with Nelaton tip |
| Number of ways | 2 (urinary drainage + balloon inflation) |
| Material | Medical-grade latex with silicone coating |
| Gauge | CH 16 (16 Fr / Charrière-French scale) |
| Balloon capacity | 30 ml |
| Length | 40 cm |
| Distal end | Straight Nelaton tip, with lateral drainage eyes |
| Connection | Valve compatible with Luer-type syringe; connector for urine collection bag |
| Intended use | Continuous and post-surgical bladder urinary drainage in adults |
| Sterility | Sterile, single-use, individually packaged |
| Presentation | Box of 10 units |
| Reference | 663016 |
Range of calibres in the two-way Nelaton series with 30 ml balloon (length 40 cm):
| Reference | Gauge | Cuff | Ways |
| 663012 | CH 12 | 30 ml | 2 |
| 663014 | CH 14 | 30 ml | 2 |
| 663016 | CH 16 | 30 ml | 2 |
| 663018 | CH 18 | 30 ml | 2 |
| 663020 | CH 20 | 30 ml | 2 |
| 663022 | CH 22 | 30 ml | 2 |
| 663024 | CH 24 | 30 ml | 2 |
| 663026 | CH 26 | 30 ml | 2 |
4. Equivalences and Cross-References
By specifications (CH 16 calibre, 30 ml balloon, two-way, Nelaton tip and silicone-coated latex), this catheter is comparable and interchangeable with 16 Fr silicone-coated latex Foley catheters from manufacturers such as Rüsch/Teleflex, Bard (BD group), Coloplast or B. Braun, without the need to modify the placement protocol or connection accessories. The Charrière (CH) scale is directly equivalent to the French (Fr) scale, so the CH 16 calibre is interchangeable, always checking balloon, length and material.
Within the Cahnos catalogue, the same two-way configuration with a 5-10 ml balloon corresponds to the 6620xx series (in CH 16: ref. 662016); the version with Tiemann tip and 30 ml balloon corresponds to the 6660xx series (ref. 666016 in CH 16), recommended for complex prostatic anatomy or strictures; and if simultaneous bladder irrigation is required, the three-way version ref. 668016 can be considered. For patients with latex allergy or medium- and long-term catheterisations, the 100% silicone range (ref. 643016 in CH 16) is recommended, which allows all bladder drainage cases to be covered with a single supplier.
5. Selection tips and variants of interest
Always select the smallest calibre that guarantees adequate drainage under medical criteria: CH 14, CH 16 and CH 18 are the most common calibres in standard adult catheterisation, while CH 20 and above are reserved for high flow requirements, urine with sediment, haematuria or post-surgical drainage with higher flow. The 30 ml balloon offers a larger fixation surface and a lower risk of accidental expulsion than 5-10 ml balloons, being recommended in urinary retention requiring assisted bladder emptying.
Always inflate the balloon with the recommended volume of sterile water or physiological saline, use compatible water-soluble lubricant and aseptic technique, and connect the collection bag with a closed system to minimise the risk of catheter-associated urinary tract infection. Check the integrity of the sterile packaging before each use. To complete the drainage system, we recommend combining this catheter with our urine collection bags. Contact our technical-commercial team for special volume purchase conditions for hospitals and purchasing centres.




Reviews
There are no reviews yet.