We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Siliconised Latex Foley Catheter Two-Way Nelaton | PVC Valve | 5-10 ml Balloon | CH 18 (18 Fr) | Length 40 cm | Sterile

7,85 €

Two-way siliconised latex Foley catheter with Nelaton tip, gauge CH 18 (18 Fr), 5-10 ml retention balloon, PVC valve and length 40 cm. Sterile single-use urethral catheter, indicated for continuous and post-surgical urinary drainage in adult patients in urology, hospitalisation, surgery and intensive care departments. The silicone coating reduces friction on the urethral mucosa, facilitates comfortable and atraumatic insertion and minimises the risk of irritation and encrustation. Includes PVC valve compatible with Luer-type syringe and standard connector for urine collection bag. Presentation in box of 10 units. Reference 662018.

International shipping. Import duties and taxes are payable by the recipient.

Reference
662018
Tags

Description

1. Introduction

The two-way siliconised latex Foley catheter with Nelaton tip, CH 18 gauge and 5-10 ml balloon (ref. 662018) is a single-use retention urethral catheter, made of medical-grade latex with silicone coating. It is indicated for effective, safe and controlled urinary drainage in adult patients, in urology, hospitalisation, surgery, intensive care and post-surgical care departments. Its excellent value for money and its configuration with PVC valve make it a reliable and economical solution for hospitals, clinics, social health centres and healthcare professionals who need a constant and approved supply.

2. Technical explanation of the device

The Foley catheter is a retention urinary catheter that is inserted through the urethra into the bladder. This two-way version integrates two independent channels in the same body: a main drainage channel through which urine flows to the collection bag and a secondary inflation channel connected to the retention balloon. Once the catheter is placed, the balloon is filled with sterile water or saline solution (5-10 ml), which anchors the catheter inside the bladder and prevents accidental displacement during treatment or postoperative recovery.

The straight Nelaton tip, with lateral drainage eyes, facilitates linear and atraumatic insertion, while the silicone coating over the latex reduces friction on the urethral mucosa, minimises the risk of irritation and encrustation and promotes tolerance in short- and medium-term catheterisation. The PVC valve allows balloon inflation with a Luer-type syringe and guarantees a hermetic seal of the system during the indwelling period. The CH 18 gauge is one of the most common sizes in standard adult catheterisation and offers an excellent balance between drainage flow and patient comfort.

3. Technical Specifications

Catheter type Straight two-way Foley catheter with Nelaton tip
Number of ways 2 (urinary drainage + balloon inflation)
Material Medical-grade latex with silicone coating
Gauge CH 18 (18 Fr / Charrière-French scale; external diameter approx. 6.0 mm)
Balloon capacity 5-10 ml
Length 40 cm
Distal end Straight Nelaton tip, with lateral drainage eyes
Connection PVC valve compatible with Luer-type syringe; connector for urine collection bag
Intended use Continuous and post-surgical bladder urinary drainage in adults
Sterility Sterile, single-use, individually packaged
Presentation Box of 10 units
Reference 662018

Range of sizes of the two-way Nelaton series with PVC valve and 5-10 ml balloon (length 40 cm):

Reference Gauge Cuff Ways
662012 CH 12 5-10 ml 2
662014 CH 14 5-10 ml 2
662016 CH 16 5-10 ml 2
662018 CH 18 5-10 ml 2
662020 CH 20 5-10 ml 2
662022 CH 22 5-10 ml 2
662024 CH 24 5-10 ml 2
662026 CH 26 5-10 ml 2

4. Equivalences and Cross-References

By specifications (CH 18 gauge, 5-10 ml balloon, two-way, Nelaton tip and siliconised latex), this catheter is comparable and interchangeable, without the need to modify the insertion protocol or connection accessories, with 18 Fr siliconised latex Foley catheters from manufacturers such as Rüsch/Teleflex (Rüsch Gold range), Bard (BD group), Coloplast or B. Braun. The Charrière (CH) scale is directly equivalent to the French (Fr) scale, so the CH 18 gauge is interchangeable, always verifying balloon, length, valve and material.

Within the Cahnos catalogue, the same two-way Nelaton configuration with rubber valve corresponds to ref. 662218 (CH 18); the version with 30 ml balloon corresponds to the 6630xx series (ref. 663018 in CH 18); the variant with Tiemann tip corresponds to the 6660xx series (ref. 666018), recommended in complex prostatic anatomy or stenosis; and if simultaneous bladder irrigation is required, the three-way version (ref. 668018) may be considered. For patients with latex allergy or medium- and long-term catheterisation, the 100% silicone range (ref. 643018) is recommended, allowing all bladder drainage cases to be covered with a single supplier.

5. Selection tips and variants of interest

The CH 18 gauge is one of the most frequent sizes in adult patient catheterisation, suitable for standard drainage and for medium-high flow requirements, such as urine with sediment or post-surgical drainage. Always select the smallest gauge that guarantees adequate drainage under medical criteria: CH 14 and CH 16 for narrower urethras or lower demand, and CH 20 or higher when high flow is required (haematuria, sediment or high-flow post-surgical cases).

The 5-10 ml balloon is the usual option for bladder fixation in short- and medium-term catheterisation, offering a lower volume profile and great comfort. Inflate the balloon only after confirming correct bladder placement, with the recommended volume of sterile water or saline solution, and use compatible water-soluble lubricant and aseptic technique. Connect the collection bag with a closed system to minimise the risk of catheter-associated urinary tract infection and check the integrity of the sterile packaging before each use. To complete the drainage system, we recommend combining this catheter with our urine collection bags. Consult our technical-commercial team for special volume purchase conditions for hospitals and purchasing groups.

Additional information

Material

Medical-grade latex with silicone coating

Gauge

CH 18 (18 Fr, Charrière-French scale)

Approx. external diameter

6.0 mm

Number of ways

2 (urinary drainage + balloon inflation)

Balloon capacity

5-10 ml

Distal end

Straight Nelaton tip with lateral drainage eyes

Connection

PVC valve compatible with Luer-type syringe; connector for collection bag

Intended use

Continuous and post-surgical bladder urinary drainage in adults

Sterility

Sterile, single-use, individually packaged

Presentation

Box of 10 units

Reference

662018

Longitud

40 cm

Reviews

There are no reviews yet.

Be the first to review “Siliconised Latex Foley Catheter Two-Way Nelaton | PVC Valve | 5-10 ml Balloon | CH 18 (18 Fr) | Length 40 cm | Sterile”

Your email address will not be published. Required fields are marked *