Description
1. Introduction
The two-way silicone-coated latex Foley catheter with Nelaton tip, CH 20 and 5-10 ml balloon (ref. 662020) is a single-use retention urethral catheter, manufactured from medical-grade latex with a silicone coating. It is indicated for effective and controlled urinary drainage in adult patients in urology, hospitalisation, surgery, intensive care and post-surgical care services. Its excellent value for money makes it a reliable and cost-effective solution for hospitals, clinics, social-health centres and healthcare professionals that require a constant and approved supply.
2. Technical explanation of the device
The Foley catheter is a retention urinary catheter that is inserted through the urethra into the bladder. This two-way version integrates two independent channels in a single body: a main drainage channel through which urine flows into the collection bag and a secondary inflation channel connected to the retention balloon. Once in place, the balloon is filled with sterile water or physiological saline (5-10 ml), anchoring the catheter inside the bladder and preventing accidental displacement during treatment or postoperative recovery.
The straight Nelaton tip, with lateral drainage holes, facilitates linear and atraumatic insertion, while the silicone coating over the latex reduces friction on the urethral mucosa, minimises the risk of irritation and encrustation and promotes tolerance in short- and medium-term catheterisation. The CH 20 (20 Fr) gauge offers a wide drainage flow rate, ideal for the adult patient when a generous evacuation flow is required, such as in cases of urine with sediment, haematuria or higher-flow postoperative drainage.
3. Technical Specifications
| Catheter type | Straight two-way Foley catheter with Nelaton tip |
| Number of ways | 2 (urinary drainage + balloon inflation) |
| Material | Medical-grade latex with silicone coating |
| Gauge | CH 20 (20 Fr / Charrière scale) |
| Balloon capacity | 5-10 ml |
| Length | 40 cm |
| Distal end | Straight Nelaton tip, with lateral drainage eyes |
| Connection | PVC valve compatible with Luer-type syringe; connector for urine collection bag |
| Intended use | Continuous and post-surgical bladder urinary drainage in adults |
| Sterility | Sterile, single-use, individually packaged |
| Presentation | Box of 10 units |
| Reference | 662020 |
Range of sizes of the two-way Nelaton series with PVC valve and 5-10 ml balloon (length 40 cm):
| Reference | Gauge | Cuff | Ways |
| 662012 | CH 12 | 5-10 ml | 2 |
| 662014 | CH 14 | 5-10 ml | 2 |
| 662016 | CH 16 | 5-10 ml | 2 |
| 662018 | CH 18 | 5-10 ml | 2 |
| 662020 | CH 20 | 5-10 ml | 2 |
| 662022 | CH 22 | 5-10 ml | 2 |
| 662024 | CH 24 | 5-10 ml | 2 |
| 662026 | CH 26 | 5-10 ml | 2 |
4. Equivalences and Cross-References
By specifications (CH 20 gauge, 5-10 ml balloon, two-way, Nelaton tip and silicone-coated latex), this catheter is comparable and interchangeable with 20 Fr silicone-coated latex Foley catheters from manufacturers such as Rüsch/Teleflex (Rüsch Gold range), Bard (BD group), Coloplast or B. Braun, without the need to modify the placement protocol or connection accessories. The Charrière (CH) scale is directly equivalent to the French (Fr) scale, so the CH 20 gauge is interchangeable, always verifying balloon, length and material.
Within the Cahnos catalogue, the same two-way Nelaton configuration with a 5-10 ml balloon and rubber valve corresponds to the 6622xx series (ref. 662220 in CH 20); the version with a 30 ml balloon corresponds to the 6630xx series (ref. 663020 in CH 20); the variant with a Tiemann tip and 5-10 ml balloon is the 6650xx series (ref. 665020), recommended for complex prostatic anatomy or strictures; and if simultaneous bladder irrigation is required, the three-way version ref. 668020 may be considered. For patients with latex allergy or medium- and long-term catheterisation, the 100% silicone range (6430xx series) is recommended, allowing all bladder drainage cases to be covered with a single supplier.
5. Selection tips and variants of interest
Always select the smallest gauge that ensures adequate drainage under medical criteria: the intermediate gauges CH 14, CH 16 and CH 18 are the most common in standard adult catheterisation, while CH 20 is reserved for high-flow requirements, urine with sediment, haematuria or higher-flow postoperative drainage. In the same 6620xx series, gauges from CH 12 to CH 26 are available, all with a 5-10 ml balloon and PVC valve. If you need a larger fixation surface and lower risk of accidental expulsion, consider the 30 ml balloon (6630xx series).
Always inflate the balloon with the recommended volume of sterile water or physiological saline, use a compatible water-soluble lubricant and aseptic technique, and connect the collection bag with a closed system to minimise the risk of catheter-associated urinary tract infection. Check the integrity of the sterile packaging before each use. To complete the drainage system, we recommend combining this catheter with our urine collection bags. Contact our technical-commercial team for special volume purchase conditions for hospitals and purchasing groups.





Reviews