We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Graduated 4-way oesophageal manometry catheter C58U – Perfused catheter for oesophageal motility study (L ≈ 150 cm, Ø 3 mm / 10 CV and Ø 5 mm / 15 CV)

Price on request

Graduated 4-way oesophageal manometry catheter (ref. C58U) for precise and simultaneous recording of intra-oesophageal pressures via 4 perfused ports spaced 5 cm apart, with an approximate length of 150 cm and a graduated body in centimetre scale. Available in Ø 3 mm (10 CV, ref. C58033U) and Ø 5 mm (15 CV, ref. C58050U), it is perfused with sterile water at a constant flow rate and connected to the transducers of the manometry system. Essential tool for the diagnosis of oesophageal motility disorders in gastroenterology departments, digestive physiology units and motility laboratories. Supply on request and formal quotation with special conditions for B2B professionals.

International shipping. Import duties and taxes are payable by the recipient.

Reference
C58U

Description

1. Introduction

The graduated 4-way oesophageal manometry catheter (ref. C58U) is the reference solution for your gastroenterology department, digestive physiology unit or motility laboratory that needs to rigorously study the motor activity of the oesophagus. Its multichannel perfusion design allows obtaining stable, reproducible and clinically reliable pressure curves in a single examination, facilitating the identification of functional and oesophageal transit alterations with high diagnostic reliability.

2. Technical explanation of the equipment and procedure

Oesophageal manometry measures the intraluminal pressures generated by the oesophageal wall during swallowing and at rest. The C58U catheter is inserted nasally or orally and advanced until the recording points are positioned at the level of the oesophageal body; each of its four channels is connected to a pressure transducer of the manometry system and perfused with sterile water at a constant flow rate. Thus, the four ports, spaced 5 cm apart, simultaneously record pressure at different points of the oesophagus, allowing assessment of oesophageal motility, peristaltic wave and correct bolus transit, guiding the diagnosis of functional disorders such as achalasia, gastro-oesophageal reflux or peristalsis alterations. The graduated body with a centimetre scale facilitates accurate and reproducible placement, while the independent lumens avoid interference between channels and ensure clean and clinically reliable signals throughout the examination.

3. Technical Specifications

The main features of the C58U oesophageal manometry catheter are summarised in the following table:

Reference (SKU) C58U
Configuration 4 pressure recording channels (perfusion manometry)
Port distribution 4 perfused ports spaced 5 cm apart
Total length L ≈ 150 cm
Diameter Ø 3 mm (10 CV) and Ø 5 mm (15 CV)
Measurement system Constant-flow sterile water perfusion
Graduation Graduated body with centimetre scale
Recording zone Oesophageal body, distal oesophagus and cardia
Application Oesophageal manometry, study of motility and oesophageal transit

Available versions according to internal diameter:

Reference Internal diameter Equivalence
C58033U Ø 3 mm 10 CV
C58050U Ø 5 mm 15 CV

With its 4 measurement points aligned every 5 cm, the catheter allows building a structured pressure profile of the oesophagus and tracking the peristaltic wave along the oesophageal body in a single examination.

4. Equivalences and Cross-References

The C58U meets the standard of multichannel perfusion catheter for oesophageal manometry used by the main manufacturers of digestive motility equipment. It is functionally equivalent to the water-perfused catheters from companies such as Marquat, Laborie/MMS and Albyn Medical in 4-channel configurations, as well as the perfused measurement catheters of the gastrointestinal series from the Rüsch/Teleflex group (sterile, single-use and latex-free). Within the Cahnos catalogue, its version with a more complete pressure profile is the graduated 6-way oesophageal manometry catheter C59U (3 ports at the same level above the lower oesophageal sphincter + 3 ports spaced 5 cm, L ≈ 160 cm, Ø 5 mm / 15 CV); for the paediatric population, the graduated 4-way catheter C79U is available. For the assessment of oesophageal pressure with balloon in the respiratory field, it is complemented by the C76U catheter. For exact validation of an equivalence with your centre’s current purchase reference, consult our technical-commercial team.

5. Selection tips and variants of interest

Select version C58033U (Ø 3 mm / 10 CV) when a smaller diameter is required, or version C58050U (Ø 5 mm / 15 CV) when the protocol demands a larger internal passage. If your study needs a more complete pressure profile with simultaneous recording of the lower oesophageal sphincter, consider the 6-way catheter C59U; for paediatric and infant studies, the C79U catheter. Always verify the compatibility of connectors and transducers with your manometry system and respect the perfusion flow rate recommended by the equipment manufacturer. At Cahnos we supply this device on request and formal quotation, with special conditions for B2B professionals.

Additional information

Configuration

4 pressure recording channels (perfusion manometry)

Port distribution

4 perfused ports spaced 5 cm apart

Length

L ≈ 150 cm

Gauge

Ø 3 mm (10 CV) and Ø 5 mm (15 CV)

Variants

C58033U (Ø 3 mm / 10 CV), C58050U (Ø 5 mm / 15 CV)

Measurement system

Constant-flow sterile water perfusion

Graduations

Graduated body with centimetre scale

Recording zone

Oesophageal body, distal oesophagus and cardia

Application

Oesophageal manometry, study of motility and oesophageal transit

Presentation

Supply on request and formal quotation

Reviews

There are no reviews yet.

Be the first to review “Graduated 4-way oesophageal manometry catheter C58U – Perfused catheter for oesophageal motility study (L ≈ 150 cm, Ø 3 mm / 10 CV and Ø 5 mm / 15 CV)”

Your email address will not be published. Required fields are marked *