Description
1. Commercial Introduction
The metallic replacement FIAB F9006SSC is the original spare part from the Italian manufacturer FIAB SpA (Vicchio, Florence) for its reusable thoracic suction electrodes of Ø 30 mm. Designed to restore the signal pickup capacity of your precordial electrodes without having to replace the entire assembly, this contact dome in silver/silver chloride (Ag/AgCl, referred to as SSC by the manufacturer) ensures a stable ECG signal, with very low polarisation and clean traces. It is the ideal solution for cardiology practices, emergency departments, diagnostic centres and hospitals that wish to extend the service life of their suction electrode inventory with a simple, economical replacement of original quality. Product without published price: supply is provided on quotation.
2. Technical explanation of the spare part
Thoracic suction electrodes (precordial suction cup type) are attached to the chest surface by the vacuum generated by the rubber or PVC bulb, without the need for adhesives or tapes, and pick up the electrocardiographic signal from the precordial leads (V1-V6). With use and cleaning and disinfection cycles, the metallic contact surface can wear or deteriorate, affecting the quality of the recording. This F9006SSC replacement corresponds to the dome or metallic part of the Ø 30 mm electrode with SSC sensor (chlorided silver), the configuration that offers a stable electrode potential and low polarisation, reducing baseline drift and interference compared with nickel-plated finishes. As it is a spare part, it must be mounted on the bulb and the holding body of the compatible FIAB electrode, previously checking the condition of the suction cup and the patient cable connector.
3. Technical specifications and tables
Data verified against the manufacturer’s official catalogue (FIAB SpA, section ECG > Reusable Electrodes > Suction Chests > Spare Parts):
| Characteristic | Value |
|---|---|
| Reference FIAB | F9006SSC |
| Electrode size | Ø 30 mm |
| Packaging | 6 units |
| Units per box (web) | 6 |
| Parameter | Specification |
|---|---|
| Manufacturer | FIAB SpA (Vicchio, Florence, Italy) |
| Brand | FIAB |
| Product type | Replacement (spare part) for thoracic suction electrode for ECG |
| Alternative reference | FIAB-F9006SSC |
| Sensor / contact | SSC: silver/silver chloride (Ag/AgCl) |
| Diameter | Ø 30 mm |
| Compatibility | FIAB thoracic suction electrodes of Ø 30 mm (family of reusable precordial electrodes) |
| Presentation | Pack of 6 units |
| Category in the FIAB catalogue | ECG > Reusable Electrodes > Suction Chests > Spare Parts |
| Commercialisation | On request (no published price) |
4. Equivalences and Cross-References
No 1:1 equivalence table validated by the manufacturer and relating the F9006SSC replacement to identical codes from other manufacturers has been found in reliable sources. This spare part belongs to the FIAB family of reusable thoracic suction electrodes with SSC sensor; within the same range, the references FIAB F9003SSC (thoracic suction electrode Ø 30 mm, complete set), F9008SSC (Ø 15 mm, paediatric), F9009SSC (Ø 24 mm) and F9024SSC (limb forceps) allow you to complete or cross-check your inventory. Before any replacement or assembly, verify the diameter (Ø 30 mm), the sensor material (Ag/AgCl), the suction cup system and the patient cable connector with the Cahnos technical department.
5. Selection tips and variants of interest
The Ø 30 mm diameter is the recommended size for adult patients and medium-to-large chests, where a larger pickup surface is required to obtain a robust signal. For other populations, the same FIAB family offers suction electrodes of Ø 24 mm (F9009SSC) and Ø 15 mm (F9008SSC); always choose the size that guarantees a complete and stable vacuum seal. Check that the replacement dome matches the Ø 30 mm of your electrode and inspect the condition of the bulb and connector (4 mm banana, DIN or clip, depending on the patient cable) before assembly. Given its reusable nature, always follow the manufacturer’s cleaning and disinfection instructions and periodically check the condition of the silver coating to maintain optimal signal quality. For institutional orders, tenders or supply contracts, contact our technical-commercial department to confirm compatibility and a formal quotation.





Reviews