Description
1. Introduction
The RIESTER paediatric SpO2 sensor (ref. 13301) is the optional accessory designed by the German manufacturer Rudolf Riester for the RVS-100 vital signs monitor. Designed to extend pulse oximetry monitoring to child patients, this sensor allows paediatric services, emergency departments, primary care clinics and hospitalisation units to complete the monitoring station with an original, reliable solution from the same product family. Distributed in the healthcare channel under reference 33805, it guarantees connection compatibility and the performance expected by the equipment manufacturer.
2. Technical explanation
Pulse oximetry is a non-invasive technique that measures blood oxygen saturation (SpO2) by spectrophotometry: the sensor emits red and infrared light through the capillary bed of the patient’s finger and analyses the differential absorption between oxygenated and deoxygenated haemoglobin, simultaneously calculating heart rate. On the RVS-100 monitor, the Riester Oximax SpO2 module covers a measurement range of 0-100 % with 1 % resolution, accuracy of ±2 % in the 70-100 % range and averaging time setting (4, 8 or 16 seconds). This paediatric-type sensor ensures optimal contact in child patients and facilitates continuity of care in both spot-check and triage modes and continuous monitoring, with reliable detection even in patients with low peripheral perfusion.
3. Technical Specifications
| Brand | Riester |
|---|---|
| Manufacturer’s reference (Riester) | 13301 |
| Reference | 33805 |
| SKU Cahnos | GM33805 |
| Sensor type | Paediatric SpO2 pulse oximetry sensor (children) |
| Compatibility | RIESTER RVS-100 vital signs monitor |
| Sales unit | 1 pc |
| Device type | Medical device (Medical device) |
| Device class | I |
| EAN | 4045396213449 |
RVS-100 monitor SpO2 module specifications
| SpO2 measurement range | 0-100 % (resolution 1 %) |
|---|---|
| SpO2 accuracy | ±2 % (70-100 %) / ±3 % (40-69 %) |
| Averaging time | 4, 8 or 16 seconds |
| Heart rate | 20-250 bpm (resolution 1 bpm) |
| SpO2 alarm range | 0-100 % |
Available references
| SKU Cahnos | Reference | Riester reference | Description |
|---|---|---|---|
| GM33805 | 33805 | 13301 | RIESTER paediatric SpO2 sensor for RVS-100 (optional) |
4. Equivalences and Cross-References
This sensor corresponds to the original RIESTER manufacturer code 13301, distributed in the healthcare channel under reference 33805 (SKU Cahnos GM33805). According to the source catalogue, it is intended for the RIESTER RVS-100 vital signs monitor as an optional pulse oximetry accessory for paediatric patients. There is no manufacturer-validated equivalence table declaring this sensor interchangeable with sensors from other brands: the connectors and reading protocol of each monitor are specific to each manufacturer. Before replacing a sensor in a mixed equipment fleet or in a tender specification, confirm compatibility with your exact monitor model through the Cahnos technical-commercial department.
5. Selection tips and variants of interest
This paediatric sensor (GM33805, ref. 13301) is the ideal complement for the RIESTER RVS-100 multiparameter monitors in their GM33800 (1960-RRXPE) and GM33801 (1960-RRBPE) versions, which include adult pulse oximetry, non-invasive blood pressure and printer as standard. To complete the monitoring station, at Cahnos you will also find the official accessories from the same RVS-100 family: replacement adult SpO2 sensor (GM33806, ref. 13302), trolley with basket (GM33810, ref. 13317) for moving the monitor between points of care, and paediatric Velcro cuff (GM33813, ref. 129,006). It is recommended to have one replacement sensor per unit and to periodically check the condition of the clip and the connection cable. For institutional orders, tenders or purchasing groups, contact our technical-commercial department. For large orders you can request a quote.