Paediatric SpO2 Finger Clip Sensor (10-50 kg) APK Technology | Ref. 21.13-5203 | Compatible with Palmcare DUO and M Series Monitors

69,00 €

Paediatric SpO2 finger clip sensor, designed for paediatric patients from 10 to 50 kg and manufactured by APK Technology (reference 21.13-5203 / MEC21.13-5203). It offers non-invasive, continuous and reliable monitoring of oxygen saturation (SpO2) and pulse rate in paediatric consultations, emergency departments, hospitalisation wards and home care. Its clip system fits firmly onto the patient’s finger, ensuring stable positioning during measurement, and its 1.5 m cable provides the necessary freedom of movement in the healthcare environment. It is compatible with the Palmcare DUO equipment and the M800, M850, M860, M880, M8500 and Q5 monitors. Product distributed through the medical ECONET catalogue. Sale on quotation: contact our technical-commercial team at Cahnos.

International shipping. Import duties and taxes are payable by the recipient.

Reference
MEC21.13-5203

Description

1. Commercial Introduction

The paediatric SpO2 finger clip sensor from APK Technology (ref. 21.13-5203) is the pulse oximetry accessory your centre needs for continuous, non-invasive monitoring of blood oxygen saturation and pulse rate in paediatric patients from 10 to 50 kg. Manufactured by APK Technology and distributed through the medical ECONET catalogue, this reusable clip sensor combines a compact, ergonomic design with the robustness required for daily use in consulting rooms, emergency departments, paediatrics, hospitalisation and home care. An ideal replacement or expansion solution to keep your fleet of pulse oximeters and monitors from the Palmcare family and the M series operational.

2. Technical explanation

Pulse oximetry is a non-invasive optical technique that measures the functional oxygen saturation of arterial haemoglobin (SpO2) by spectrophotometry: the sensor incorporates red and infrared light emitters that pass through the capillary bed of the finger and a photodetector that quantifies differential absorption according to the degree of blood oxygenation. From this plethysmographic signal, the monitor calculates and displays the SpO2 value and pulse rate in real time.

This sensor, in the finger clip (clipsensor) format, is specifically designed for the anatomy of the paediatric patient from 10 to 50 kg, ensuring a stable and comfortable fit during monitoring. Its 1.5 m cable facilitates connection to the equipment with sufficient room for manoeuvre. Being a reusable model, it allows continued use with proper cleaning and disinfection between patients, optimising the cost per measurement compared with disposable sensors.

3. Technical Specifications

Parameter Specification
Sensor type SpO2 finger clip sensor (clipsensor), reusable
Patient population Children / paediatric: 10-50 Kg
Cable length 1.5 m
Brand APK Technology
Manufacturer references 21.13-5203 (MEC21.13-5203)
Use / presentation Reusable; intended for clinical use. Indicative image (Abb. ähnlich).

Equipment compatibility

  • Palmcare DUO
  • M800
  • M850
  • M860
  • M880
  • M8500
  • Q5

Available references

Reference Description
21.13-5203 (MEC21.13-5203) Paediatric SpO2 finger clip sensor (10-50 kg), 1.5 m cable (this item)

Note: the sensor is supplied with an integrated 1.5 m cable. To extend the connection distance, compatible extension accessories may be considered (see block 5).

4. Equivalences and Cross-References

This product corresponds to reference 21.13-5203 in the medical ECONET catalogue, within the range of SpO2 sensors manufactured by APK Technology for the Palmcare DUO equipment and the M800/M850/M860/M880/M8500 and Q5 series. No validated 1:1 equivalents with sensors from other manufacturers have been found in reliable sources, since compatibility depends on the connector and the specific electronic protocol of each monitor.

Within the same family of sensors for these devices, the original catalogue includes other variants in the range: the SpO2 Fingerclipsensor für Erwachsene (adult clip sensor, 1.5 m cable), the SpO2 Softtouchsensor für Kinder and the SpO2 Softtouchsensor für Erwachsene (soft contact sensors, 1.5 m cable), as well as extension cables and SpO2 adapters. Before replacing any catheter in use, confirm the exact brand, model and connector of your monitor with our technical-commercial department.

5. Selection tips and variants of interest

Always verify the exact model of your device: this paediatric clip sensor is the one indicated for patients from 10 to 50 kg and for the Palmcare DUO, M800, M850, M860, M880, M8500 and Q5 monitors. For heavier patients, consider the adult clip variant from the same family (same 1.5 m cable); if your department prefers a soft contact fixation instead of a clip, the range includes the paediatric and adult Softtouch sensors.

As it is a reusable sensor, it is recommended to periodically check the condition of the clip, the optical surfaces and the cable, and to replace the sensor at any sign of wear to ensure measurement reliability. For institutional orders, supply contracts or tendering processes, contact the technical-commercial team at Cahnos; this product is sold on a quotation basis.

Additional information

Manufacturer reference

21.13-5203 / MEC21.13-5203

Sensor type

SpO2 finger clip sensor (clipsensor)

Patient population

Paediatric: 10-50 Kg

Cable length

1.5 m

Compatibility

Palmcare DUO; M800, M850, M860, M880, M8500, Q5

Catalogue distributor

medical ECONET GmbH

Presentation

Indicative image (similar illustration)

Tipo uso

Reusable

Reviews