Description
1. Commercial Introduction
The extension cable for SpO2 sensors (ref. 35304) is the essential accessory for gaining flexibility in oxygen saturation monitoring: it allows the pulse oximetry probe to be connected to the monitor while maintaining a comfortable and safe working distance, both at a fixed station and during intra-hospital transfers. Designed for sensors compatible with Nellcor probe technology (codes 35255-35261 / 35255-61), it is supplied per unit and is especially useful as a spare part or for completing multiparameter equipment and bedside monitors in hospital wards, emergency departments and ICUs.
2. Technical Explanation
Pulse oximetry (SpO2) is a non-invasive optical technique that measures the functional oxygen saturation of arterial haemoglobin through the differential absorption of red and infrared light across the vascular bed. The signal captured by the probe is transmitted to the monitor via a dedicated cable; when the distance between the patient and the equipment is greater than expected, the extension cable acts as an intermediate element that extends the sensor’s reach without altering the signal or the communication protocol.
This accessory is designed for sensors of the Nellcor standard (probe family 35255-35261 / 35255-61), a system widely implemented in bedside, transport and multiparameter monitors. As it is a reusable product, it must be kept in good condition and the integrity of the connector and insulation must be checked periodically to ensure reliable signal transmission.
3. Technical Specifications
Product data
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 35304 / 35255-35261 (extension cable for Nellcor SpO2 sensors) |
| Sales unit | 1 unit |
| Device type | Medical device |
| Device class | I |
| CND | Z12039080 |
| EAN | 6900234400055 |
Compatibility: SpO2 pulse oximeter sensors compatible with Nellcor probe (codes 35255-61 / 35255-35261), with the communication speed and protocol specific to the family standard. Reusable product, supplied per unit.
4. Equivalences and Cross-References
This extension cable is part of the manufacturer’s range of pulse oximetry accessories and is designed for the Nellcor probe standard. In the Cahnos catalogue there is no official manufacturer table validating a 1:1 cross-reference of this reference with cables from other manufacturers; the following items are related at the level of functional compatibility and must be verified field by field (connector, protocol and monitor model) before replacement:
| Product / Family | Reference | Related items |
|---|---|---|
| Nellcor-compatible SpO2 pulse oximeter sensors with 9-pin connector (DB9) | 18631 (adult), 18632 (paediatric), 18633 (infant), 18634 (adult/neonate) | Family of sensors of the same Nellcor/Oxismart standard in the Cahnos catalogue |
| M10 vital signs monitor with Nellcor-compatible SpO2 | 51-6005 | Bedside unit that includes an SpO2 probe extension cable in its standard equipment |
Note: always verify the monitor’s protocol variant (Oxisensor/OxiMax) and the probe connector type before placing the order, as the electrical scheme of the Nellcor standard has versions that must be confirmed with the installed equipment.
5. Selection tips and variants of interest
Always state the model and brand of your monitor or pulse oximeter to confirm the compatibility of the extension cable with the connector of the installed SpO2 probe. If the department works with Nellcor standard sensors with a 9-pin connector, the Cahnos catalogue offers compatible single-use per-patient sensors (refs. 18631, 18632, 18633 and 18634) in economical boxes of 25 units, as well as reusable clips from the same family. Be sure to periodically check the condition of the cable (connectors, insulation and bends) and avoid sharp bends that could damage the internal wires. For equipment supplies, scheduled replacements or institutional orders, contact the technical-commercial department at Cahnos: this product has no published stock.




Reviews