Description
1. Commercial Introduction
The extension cable for the SpO2 pulse oximeter sensor (code 35232), reference 35302, is the ideal accessory for extending the distance between the oxygen saturation probe and the monitor or measuring device. This original cable, from one of the main European distributors of medical supplies, guarantees the compatibility and signal quality that your service needs for reliable, continuous monitoring.
Designed for care settings such as hospital wards, emergency departments, outpatient clinics and intra-hospital transport, it allows the probe to be placed on the patient with greater freedom of movement, avoiding strain on the cable and improving comfort during monitoring. A basic, low-cost spare that should always be kept available in the centre’s stock.
2. Technical Explanation
Pulse oximetry (SpO2) non-invasively measures blood oxygen saturation through the differential absorption of red and infrared light across the capillary bed. The probe detects this signal and transmits it to the monitor via a connector cable; when the distance between the patient and the equipment is insufficient, an extension cable such as model 35302 is inserted, establishing the electrical link between the probe (code 35232) and the device.
This accessory is classified as a Class I medical device, in accordance with the applicable European regulations, and is supplied as a single unit. As it is a passive connection element, it does not interfere with measurement accuracy provided it is used with the compatible probe indicated by the manufacturer.
3. Technical Specifications
Product characteristics verified in the manufacturer’s official catalogue (Product_DB.csv):
| Manufacturer | GIMA |
|---|---|
| Sales unit | 1 pc |
| Device type | Medical device |
| Device class | I |
| CND | Z12039080 |
| EAN | 6900234400031 |
Available references
| Reference | Description |
|---|---|
| 35302 | Extension cable for SpO2 pulse oximeter sensor (code 35232) |
| 35232 | Compatible SpO2 sensor to which the extension cable connects |
4. Equivalences and Cross-References
No official equivalence table validated by the manufacturer is available to confirm the interchangeability of this reference with extension cables from other brands. To guarantee signal integrity and patient safety, it is recommended to use the extension cable with the SpO2 probe of the same brand (code 35232) and to verify connector compatibility with the corresponding monitor before purchase.
In the Cahnos catalogue there are other extension cables in the monitoring family (such as the probe extension cable for handheld pulse oximeters and the extension cable for blood pressure monitors and arterial pressure monitors, ref. GM32917) that perform a similar function but with different connectors and equipment; they are not interchangeable with each other without prior technical validation.
5. Selection tips and variants of interest
- Always confirm the reference of the installed probe: this cable is designed for the SpO2 sensor with code 35232. If your monitor uses a different probe, contact our technical-commercial department to find the correct accessory.
- Check the monitor connector before ordering: connector compatibility is essential for the extension to work correctly.
- Keep several spare extension cables in stock: they are common wear items in departments with high patient turnover and facilitate the rotation of material between beds and bays.
- Complete your provision with spare SpO2 probes, electrodes and other monitoring accessories from the Cahnos catalogue for comprehensive service management.
- For institutional orders, supply contracts or technical clarifications on compatibility, contact the Cahnos technical-commercial department. For large orders you can request a quote.





Reviews