Description
1. Introduction
The disposable otoscope speculum model W of 2.5 mm (ref. 2472025B) is the single-use accessory that every ear, nose and throat (ENT), paediatrics, general medicine and emergency department needs to combine hygiene, patient comfort and full compatibility with the most widespread Welch Allyn otoscopes on the market. With a 2.5 mm opening, it is indicated for narrow or paediatric ear canals and is supplied in a bag of 1,000 units to guarantee continuous stock for the clinic or hospital at a very competitive cost per examination.
Being a single-use device, each patient has a new and clean speculum, which avoids reprocessing of instruments between consultations, reduces the risk of cross-contamination (from ear to ear and from patient to patient) and streamlines workflow in high-turnover environments.
2. What it is and how it is used
Otoscopy allows inspection of the external auditory canal and the tympanic membrane. The speculum attaches to the otoscope head and acts as a light funnel and insertion guide: it keeps the auditory meatus open without resting on the sensitive bony area and channels the device’s illumination towards the back of the canal for a clear view of the eardrum.
The diameter of 2.5 mm corresponds to the size indicated for small ear canals and paediatric patients; it is recommended to select the size according to each patient’s anatomy (4 mm for adults and standard canals) and to use a new speculum for each ear examined. The fitting follows the bayonet-type attachment system of Welch Allyn heads: always check the seating of the speculum on the specific head before starting the examination and dispose of it after use in the clinical waste container. Made of high-impact polystyrene, it retains its geometry during insertion and is suitable for patients sensitised to latex.
3. Technical Specifications
The following specifications correspond to the technical data sheet and manufacturer’s declaration (ANSM health registration), with classification as a class I medical device, non-sterile and without expiry control.
| Characteristic | Specification |
| Reference Cahnos | 2472025B |
| Manufacturer series | 24 720 25 (model W, Welch Allyn fitting) |
| Product type | Disposable ear speculum for otoscope |
| Model / attachment system | Model W (bayonet-type fitting, compatible with Welch Allyn heads) |
| Opening diameter | 2.5 mm (paediatrics / narrow ear canal) |
| Material | High-impact polystyrene (PS/HIPS), latex-free |
| Use | Single-use – not re-sterilisable, not reusable |
| Sterility | Non-sterile |
| Use duration | Temporary (less than 30 minutes) |
| Indication | Otoscopy: examination of the external auditory canal and the tympanic membrane |
| Compatibility | Otoscopes Welch Allyn (models 20000, 25020, 22800/22820, 24031 and MacroView); verify fit with the specific head |
| Presentation | Bag of 1,000 units |
| Product classification | Medical device Class I (Royal Decree 1591/2009; Directives 93/42/EEC and 2007/47/EC) |
| Health registration | ANSM BI-07823-95 |
| GMDN code | 35348 |
| Expiry | Not applicable (no date control in storage) |
| Storage | Dry, clean place, protected from direct sunlight |
4. Equivalences and Cross-References
The model W speculum (Ø 2.5 mm, disposable) replicates the bayonet-type attachment system of Welch Allyn disposable specula and matches in function, paediatric clinical use and single-use concept with references from the original manufacturer and alternative brands in the sector. The following references have been cross-checked against catalogues of authorised distributors and the manufacturer’s official store; they are listed as a verified functional comparison, not as an official equivalence certified by the manufacturer.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Hillrom / Welch Allyn | KleenSpec® Disposable Ear Specula paediatric (Welch Allyn otoscopes 20000, 25020, 22800/22820, 24031 and MacroView) | 52432-U | Comparable by category (not interchangeable 1:1) | Same single-use concept and same Welch Allyn bayonet-type fit; nominal diameter of 2.75 mm (compared to 2.5 mm) and usual presentation in bags of 850 units. Code consistently verified in authorised Welch Allyn distributors. |
| Rudolf Riester | Disposable Ear Specula Ø 2.5 mm (black), bag of 1,000 units. | 10774-531 | Comparable by category (not interchangeable 1:1) | Same diameter (2.5 mm) and single-use, but specific fitting for the Riester system (ri-scope/e-scope/ri-mini): does not fit Welch Allyn heads without an adapter. Code verified in authorised distributor catalogues. |
| HEINE | AllSpec Disposable Tips (EcoTips) Ø 2.5 mm infant | B-000.11.128 | Comparable by category (not interchangeable 1:1) | Same diameter (2.5 mm) and single-use concept for paediatrics; specific HEINE fitting (valid for BETA 200/400, K180, Mini 3000 and Mini 3000 F.O.), not interchangeable with Welch Allyn heads. Code verified in the official technical data sheet of HEINE Optotechnik. |
There is no equivalence table validated by the manufacturer declaring this product as identical to the original Welch Allyn references; the above references are verified functional comparisons against public sources and authorised distributor catalogues, and must be confirmed with the technical department before use in tendering. The model W fitting system is specific to Welch Allyn heads and is not interchangeable with Riester, Heine, KaWe or P. Grand systems without an adapter.
5. Selection tips and variants of interest
To get the size right, consider the patient’s age and anatomy: the diameter of 2.5 mm is reserved for narrower canals or paediatric patients, while the 4 mm size (ref. 2472040B) is the standard for adults with medium or wide ear canals.
If your fleet of otoscopes is from another brand, remember that the model W is only compatible with the Welch Allyn system: for Riester otoscopes you have the model R from the catalogue (ref. 2471025B in 2.5 mm and 2471040B in 4 mm) and for Heine, KaWe or P. Grand the model H (ref. 2470125B in 2.5 mm and 2470140B in 4 mm). In high-turnover environments, the bag of 1,000 units optimises stock and reduces the cost per examination; always use a new speculum per patient and per ear and dispose of it after the examination. Store the product in a dry, clean place, away from direct sunlight; it does not require expiry control.





Reviews