Description
1. Introduction
The adult finger SpO₂ pulse oximetry sensor (Ref. 35277) is the reference monitoring accessory for equipment in the Philips family. Designed as an OEM product with the Philips reference brand, it provides direct, reliable connection of oxygen saturation and pulse rate measurement to the manufacturer’s bedside, transport and multiparameter monitors, without the need for intermediate adapters. It is the solution indicated for cardiology, emergency, ICU, operating theatre, resuscitation and inpatient ward departments that need to renew or expand the stock of reusable probes in their Philips monitor fleet.
2. Technical explanation
Pulse oximetry is a non-invasive optical technique that estimates the functional oxygen saturation of arterial haemoglobin (SpO₂) and pulse rate. The finger clip sensor (adult finger) emits light at two wavelengths through the vascular bed of the finger, and a photodetector on the opposite side analyses the differential absorption according to the degree of blood oxygenation. The sensor’s electrical design and connector follow the Philips factory reference, ensuring stable integration with compatible monitors and a quality signal during continuous monitoring of the adult patient. As a reusable sensor, it must be cleaned between patients according to the manufacturer’s instructions; all products are supplied with a manual in GB, FR, IT and ES.
3. Technical Specifications
Finger clip pulse oximetry sensor for continuous SpO₂ and pulse rate monitoring in adult patients, with direct connection cable and verified compatibility with Philips monitors. The available references and product data registered by the manufacturer are detailed below.
Available references
| Reference | Cable length | Sales unit |
|---|---|---|
| GM35277 | 1.6 m cable | 1 pc |
| GM35278 | 3.0 m cable | 1 pc |
Product data
| Manufacturer | GIMA |
|---|---|
| Sales unit | 1 pc |
| Device type | Medical device |
| Device class | II B |
| CND | C900301 |
Sensor features
| Sensor type | Adult finger clip (Adult Finger) |
|---|---|
| Reference brand | OEM – Philips |
| Cable length | 1.6 m (Ref. 35277) / 3.0 m (Ref. 35278) |
| Compatibility | Philips: M3, M4, MP20, MP30, MP40, MP50, MP70, MP80, VM4, VM6, VM8 |
| Manual included | GB, FR, IT, ES |
Note: the manufacturer’s literal description states a cable length of 1.6 m for the main reference 35277; measurements and references are kept exactly as they appear in the original catalogue.
4. Equivalences and Cross-References
This sensor is marketed as an OEM product with the Philips reference brand (Ref. 35277 and 35278) and is designed for the Philips monitors listed in the specifications. There is no manufacturer-validated equivalence table authorising a 1:1 cross-reference with other brands’ references: any replacement must verify the connector’s electrical design, the required cable length and the exact model of monitor installed. In the Cahnos catalogue there are SpO₂ sensors in the same category (for example, those compatible with Nellcor 9-pin series systems) that are comparable in function and patient population, but not interchangeable with this sensor without prior technical validation. Contact our technical-commercial department stating the monitor brand and model to confirm exact compatibility.
5. Selection tips and variants of interest
Choose the cable length according to the point of use: Ref. 35277 (1.6 m) is ideal for fixed bedside monitoring stations with the monitor close to the patient, while Ref. 35278 (3.0 m) offers greater reach for beds with the equipment mounted on a stand or in transport environments. Always verify connector compatibility with the Philips monitor model (M3, M4, MP20 to MP80 or VM4, VM6, VM8) before placing the order. As a reusable sensor for adult patients, clean it between patients following the instructions in the supplied manual (GB, FR, IT, ES) and periodically check the condition of the cable and the clip to avoid unstable readings. For fleets with several monitor brands, Cahnos also offers sensors compatible with other pulse oximetry protocols; contact our technical-commercial team for a supply adapted to your equipment base and special conditions for volume purchases and tenders.




Reviews