We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Adult SpO₂ Pulse Oximeter Sensor for Philips (Finger Clip) – Compatible with Philips Monitors | Ref. 35277, 1.6 m Cable

Price range: 109,25 € through 123,50 €

Finger SpO₂ pulse oximetry sensor for adult patients, compatible with multiparameter monitors in the Philips family (M3, M4, MP20, MP30, MP40, MP50, MP70, MP80, VM4, VM6 and VM8). Finger clip sensor (adult finger) with 1.6 m cable, reusable design and direct connection that ensures a stable reading of oxygen saturation and pulse rate during continuous monitoring. Manufactured as an OEM reference product for Philips, classified as a class II B medical device (CND C900301) and supplied with a manual in several languages. Also available in a 3.0 m cable version (Ref. 35278). For large orders you can request a quote.

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM35277-F

Description

1. Introduction

The adult finger SpO₂ pulse oximetry sensor (Ref. 35277) is the reference monitoring accessory for equipment in the Philips family. Designed as an OEM product with the Philips reference brand, it provides direct, reliable connection of oxygen saturation and pulse rate measurement to the manufacturer’s bedside, transport and multiparameter monitors, without the need for intermediate adapters. It is the solution indicated for cardiology, emergency, ICU, operating theatre, resuscitation and inpatient ward departments that need to renew or expand the stock of reusable probes in their Philips monitor fleet.

2. Technical explanation

Pulse oximetry is a non-invasive optical technique that estimates the functional oxygen saturation of arterial haemoglobin (SpO₂) and pulse rate. The finger clip sensor (adult finger) emits light at two wavelengths through the vascular bed of the finger, and a photodetector on the opposite side analyses the differential absorption according to the degree of blood oxygenation. The sensor’s electrical design and connector follow the Philips factory reference, ensuring stable integration with compatible monitors and a quality signal during continuous monitoring of the adult patient. As a reusable sensor, it must be cleaned between patients according to the manufacturer’s instructions; all products are supplied with a manual in GB, FR, IT and ES.

3. Technical Specifications

Finger clip pulse oximetry sensor for continuous SpO₂ and pulse rate monitoring in adult patients, with direct connection cable and verified compatibility with Philips monitors. The available references and product data registered by the manufacturer are detailed below.

Available references

Reference Cable length Sales unit
GM35277 1.6 m cable 1 pc
GM35278 3.0 m cable 1 pc

Product data

Manufacturer GIMA
Sales unit 1 pc
Device type Medical device
Device class II B
CND C900301

Sensor features

Sensor type Adult finger clip (Adult Finger)
Reference brand OEM – Philips
Cable length 1.6 m (Ref. 35277) / 3.0 m (Ref. 35278)
Compatibility Philips: M3, M4, MP20, MP30, MP40, MP50, MP70, MP80, VM4, VM6, VM8
Manual included GB, FR, IT, ES

Note: the manufacturer’s literal description states a cable length of 1.6 m for the main reference 35277; measurements and references are kept exactly as they appear in the original catalogue.

4. Equivalences and Cross-References

This sensor is marketed as an OEM product with the Philips reference brand (Ref. 35277 and 35278) and is designed for the Philips monitors listed in the specifications. There is no manufacturer-validated equivalence table authorising a 1:1 cross-reference with other brands’ references: any replacement must verify the connector’s electrical design, the required cable length and the exact model of monitor installed. In the Cahnos catalogue there are SpO₂ sensors in the same category (for example, those compatible with Nellcor 9-pin series systems) that are comparable in function and patient population, but not interchangeable with this sensor without prior technical validation. Contact our technical-commercial department stating the monitor brand and model to confirm exact compatibility.

5. Selection tips and variants of interest

Choose the cable length according to the point of use: Ref. 35277 (1.6 m) is ideal for fixed bedside monitoring stations with the monitor close to the patient, while Ref. 35278 (3.0 m) offers greater reach for beds with the equipment mounted on a stand or in transport environments. Always verify connector compatibility with the Philips monitor model (M3, M4, MP20 to MP80 or VM4, VM6, VM8) before placing the order. As a reusable sensor for adult patients, clean it between patients following the instructions in the supplied manual (GB, FR, IT, ES) and periodically check the condition of the cable and the clip to avoid unstable readings. For fleets with several monitor brands, Cahnos also offers sensors compatible with other pulse oximetry protocols; contact our technical-commercial team for a supply adapted to your equipment base and special conditions for volume purchases and tenders.

Additional information

Longitud del cable

1.6 m cable, 3.0 m cable

Manufacturer reference

35277 (cable 1.6 m) / 35278 (cable 3.0 m)

Sensor type

Adult finger clip (adult finger), SpO₂ pulse oximetry

OEM reference brand

Philips

Compatibility

Philips: M3, M4, MP20, MP30, MP40, MP50, MP70, MP80, VM4, VM6, VM8

Cable length

1.6 m (Ref. 35277) / 3.0 m (Ref. 35278)

Device type

Medical device (Medical device)

CND code

C900301

Manual included

GB, FR, IT, ES

Presentacion

Unit

Tipo dispositivo

Medical device

Clase sanitaria

II b

Tipo paciente

Adult

Documentation

📄 DatasheetEnglish PDF
📜 Declaration of conformityMultilingüe PDF · Multilingüe PDF
📜 CE certificateDownload PDF
📜 ISO 9001 / 13485 certificatesMultilingüe PDF
📜 CertificatesDichiarazioni Varie PDF

Reviews

There are no reviews yet.

Be the first to review “Adult SpO₂ Pulse Oximeter Sensor for Philips (Finger Clip) – Compatible with Philips Monitors | Ref. 35277, 1.6 m Cable”

Your email address will not be published. Required fields are marked *