1. Commercial Introduction
The adult finger clip SpO2 sensor from APK Technology (ref. 21.13-5202) is the pulse oximetry accessory your facility needs for continuous, non-invasive monitoring of blood oxygen saturation (SpO2) and pulse rate in adult patients. Manufactured by APK Technology and distributed through the medical ECONET catalogue, this reusable clip sensor combines a compact, ergonomic design with the robustness required for daily use in outpatient clinics, emergency departments, hospital wards and home care. An ideal replacement or expansion solution to keep your fleet of pulse oximeters and monitors from the Palmcare family and M series operational.
2. Technical explanation
Pulse oximetry is a non-invasive optical technique that measures the functional oxygen saturation of arterial haemoglobin (SpO2) by spectrophotometry: the sensor incorporates red and infrared light emitters that pass through the capillary bed of the finger and a photodetector that quantifies differential absorption according to the degree of blood oxygenation. From this plethysmographic signal, the monitor calculates and displays the SpO2 value and pulse rate in real time.
This sensor, in finger clip format (clip sensor), is designed for the adult patient anatomy, ensuring a stable and comfortable fit during monitoring. Its integrated 1.5 m cable facilitates connection to the device with sufficient working margin. As a reusable model, it allows continued use with proper cleaning and disinfection between patients, optimising the cost per measurement compared with disposable sensors.
3. Technical Specifications
| Parameter | Specification |
| Sensor type | SpO2 finger clip sensor (clipsensor), reusable |
| Patient population | Adult |
| Cable length | 1.5 m |
| Brand | APK Technology |
| Manufacturer references | 21.13-5202 (MEC21.13-5202) |
| Equipment compatibility | Palmcare DUO · M800, M850, M860, M880, M8500, Q5 |
| Reference | Description |
| 21.13-5202 (MEC21.13-5202) | Adult finger clip SpO2 sensor, 1.5 m cable (this item) |
Note: the sensor is supplied with an integrated 1.5 m cable. To extend the connection distance, compatible extension accessories may be considered (see block 5).
4. Equivalences and Cross-References
This product corresponds to reference 21.13-5202 (MEC21.13-5202) in the medical ECONET catalogue, within the range of SpO2 sensors manufactured by APK Technology for Palmcare DUO equipment and the M800/M850/M860/M880/M8500 and Q5 series. No validated 1:1 equivalents with sensors from other manufacturers have been found in reliable sources, as compatibility depends on the connector and the specific electronic protocol of each monitor.
Within the same family of sensors for these devices, the source catalogue includes other variants in the range: the paediatric finger clip SpO2 sensor (ref. 21.13-5203, for patients from 10 to 50 kg), the Softtouch sensors for adult and paediatric use (1.5 m cable), as well as extension cables and SpO2 adapters compatible with Palmcare and M series equipment. Before replacing any catheter in use, confirm the exact brand, model and connector of your monitor with our technical-commercial department.
5. Selection tips and variants of interest
Always verify the exact model of your device: this adult clip sensor is the one indicated for Palmcare DUO, M800, M850, M860, M880, M8500 and Q5 monitors. For paediatric patients from 10 to 50 kg, consider the clip variant from the same family (ref. 21.13-5203); if your department prefers a soft contact attachment instead of a clip, the range includes Softtouch sensors for adult and child.
As a reusable sensor, it is recommended to periodically check the condition of the clip, the optical surfaces and the cable, and to replace the sensor at any sign of wear to ensure measurement reliability. For institutional orders, supply contracts or tendering processes, contact the technical-commercial team at Cahnos; this product is sold on quotation.