Description
1. Commercial Introduction
The disposable prewired electrode FIAB F9054NQ/RM/80 is an ECG monitoring consumable designed specifically for paediatric and neonatal patients. Its non-woven fabric (TNT) backing of 22×22 mm, its integrated 80 cm cable and its 4 mm female connector (socket) make it the direct solution for maintaining continuous, reliable electrocardiographic recording in newborns and children, minimising the impact on their delicate skin. Manufactured by FIAB SpA (Vicchio, Florence, Italy), it is supplied in a box of 150 units (50 bags of 3 units), a format designed for the continuous supply of neonatology, paediatrics, neonatal ICU and neonatal transport services. Sale on quotation: contact our technical-commercial department for conditions and lead times.
2. Technical Explanation
The electrode acts as an interface between the patient’s skin and the bedside monitor: the non-woven fabric (TNT) backing ensures a gentle yet firm fixation on the newborn’s immature skin, with good breathability that reduces the risk of irritation during prolonged recordings. The SSC sensor element (silver/silver chloride, Ag/AgCl) on conductive gel offers a stable contact potential and low impedance, resulting in a clean ECG trace free from artefacts, even with patient movement.
The prewired 80 cm cable ends in a 4 mm female connector (socket), compatible with the lead cables of most ECG monitors and electrocardiographs with a 4 mm connection standard, eliminating the need for adapters in routine nursing practice. It is a single-use, latex-free product: it must be disposed of after each patient and the expiry date on the packaging must be respected so as not to compromise the conductivity of the adhesive or the quality of the gel.
3. Technical Specifications
| Characteristic | Value |
|---|---|
| Reference FIAB | F9054NQ/RM/80 |
| Electrode size | 22×22 mm |
| Packaging | 150 units (50 bags of 3 units) |
| Units per box (web) | 150 |
| Parameter | Specification |
|---|---|
| Brand / manufacturer | FIAB SpA (Vicchio, Florence, Italy) |
| Product type | Disposable, prewired and single-use ECG electrode |
| Population | Paediatric / neonatal |
| Support | Non-woven fabric (TNT / non woven) |
| Sensor | SSC (Ag/AgCl, silver/silver chloride) |
| Cable length | 80 cm, prewired |
| Connection | 4 mm female connector (socket) |
| Use | Single-use (disposable), latex-free |
| Application | Neonatal and paediatric ECG monitoring, neonatal ICU, incubators, neonatal transport |
Technical note: reference values, measurements, connection and presentation are taken literally from the manufacturer’s official catalogue; confirm with the technical data sheet of the supplied batch.
4. Equivalences and Cross-References
This reference belongs to the category of prewired neonatal monitoring ECG electrodes, with non-woven backing and 4 mm socket. After verifying the manufacturer’s official catalogue and authorised distribution, no 1:1 equivalence table validated by the manufacturer is available for this exact configuration. The following references are considered comparable by category (not interchangeable without field-by-field verification of backing, measurements, connector type and compatibility with the monitor’s lead cable):
| Manufacturer / Brand | Family / Model | Reference code | Equivalence level |
|---|---|---|---|
| FIAB Group | Prewired radiotransparent neonatal series, non-woven backing | F9057NQ/RM/50, F9057PRRM, F9057NRM | Comparable by category (shorter cable, DIN 1.5 mm or AAMI connector depending on version) |
| FIAB Group | Prewired neonatal foam series | F9058N / F9058NRM | Comparable by category (foam backing versus TNT) |
| 3M / Solventum (Red Dot™) | Series 2200, prewired radiolucent neonatal electrode, cloth 22×22 mm | 2282 / 2282L | Comparable by category (DIN 1.5 mm connector; verify connector) |
| Cardinal Health (Kendall™) | KittyCat™ Cloth Pre-Wired, neonatal radiolucent | 1051NPSM / 31424743 | Comparable by category (safety connector ≈1.5 mm DIN; verify connector) |
| Halbach Medical | Clinical ECG Electrode P22DR (neonatal) | EC849923 | Comparable by category (DIN 1.5 mm connector, non-woven cloth backing) |
| Medico Electrodes® | Prewired radiolucent neonatal electrode | MPGBW78RT | Comparable by category (cloth backing 22×22 mm, DIN 1.5 mm connector) |
Before any substitution, check the lead cable connector, the backing material and the patch dimensions; consult the technical department of Cahnos for use in tenders.
5. Selection tips and variants of interest
Check the connector type on your monitor: this reference uses a 4 mm female connector (socket). If your lead cable uses a DIN 1.5 mm (1.55 mm) connector, request the variants of the same FIAB family with that configuration (e.g. F9057NQ/RM series with 50 cm cable). Formats with a different connector are not interchangeable with each other without an adapter.
The 22×22 mm size is the compact format recommended for very low birth weight neonates and premature infants, reducing the adhesion surface on very delicate skin. For paediatric patients with a larger chest area, consider larger formats from the FIAB range. The non-woven fabric backing offers breathability and comfort; if imaging control is anticipated, consult the radiotransparent versions of the family.
Store the sealed bags in a dry place and respect the expiry date on the packaging: the gel may lose conductivity if the sachet deteriorates. It is a single-use, latex-free product, intended to ensure hygiene and prevent cross-contamination. For volume orders, tenders or procurement, contact the technical-commercial department of Cahnos, indicating the model of your monitor fleet and the connector type of your lead cables.