Description
1. Commercial Introduction
Complete or renew the wiring of your electrocardiograph with the ECG patient cable FIAB Ref. F5747C, a replacement accessory of proven quality manufactured by FIAB SpA (Vicchio, Florence, Italy), one of Europe’s leading specialists in cables and connectivity for electrocardiography. Designed specifically for equipment on the Fukuda Denshi platform, this cable provides stable, reliable signal transmission in daily clinical practice in cardiology outpatient clinics, emergency departments, primary care and functional diagnostic centres.
Its inspectable manifold is a key advantage: it allows the condition of the internal connections to be checked visually, facilitating preventive maintenance and extending the service life of the accessory. As this product is sold on quotation, our technical-commercial team will confirm the exact compatibility with your equipment and the supply conditions.
2. Technical Explanation
The ECG patient cable is the element in the recording chain that transmits the cardiac electrical signal picked up by the electrodes placed on the patient’s chest and limbs to the input of the electrocardiograph or monitor. The quality of the trace depends directly on the condition of the cable: deteriorated insulation, a loose connector or a fatigued flex point are sources of artefacts, interference and signal loss that can compromise the diagnosis.
This model incorporates an inspectable manifold: the housing that groups the leads can be opened to visually check the condition of the internal connections, conductors and insulation, allowing signs of wear or intermittent contacts to be detected before they affect the quality of the recording. The patient end features snap terminals (press stud, referred to as CLIP by the manufacturer), the most common press-fit fixing system in electrocardiography, which attaches quickly and securely to standard disposable ECG electrodes. The opposite, specific connector attaches to the patient port of Fukuda Denshi devices, ensuring a firm fit and clean traces with minimal interference.
3. Technical Specifications
Specifications verified in the manufacturer’s official catalogue (fiab.it, section ECG > Patient Cables > Inspectable Manifold > Snap):
| Characteristic | Value |
|---|---|
| Reference FIAB | F5747C |
| Packaging | 1 unit |
| Units per box (web) | 1 |
| Compatible with | Fukuda Denshi |
Additional catalogue data:
| Parameter | Specification |
|---|---|
| Brand | FIAB |
| Original manufacturer | FIAB SpA (Vicchio, Florence, Italy) |
| Product type | Patient cable for electrocardiography (ECG) |
| Manifold / central connector | Inspectable (openable manifold) |
| Patient connection | Snap / pressure clip (CLIP) |
| Compatibility | Equipment Fukuda Denshi |
| Application | Resting electrocardiography and monitoring |
| Catalogue category FIAB | ECG > Patient Cables > Inspectable Manifold > Snap |
| Presentation | 1 unit |
| Sales unit | On request (sold in complete boxes, per tariff) |
Available references:
| Reference | Description |
|---|---|
| FIAB-F5747C | SKU Cahnos / order reference for this product |
| F5747C | Manufacturer reference FIAB for the same cable |
Technical data according to the official catalogue of manufacturer FIAB. Measurements, models and references are copied literally; unconfirmed specifications are not included.
4. Equivalences and Cross-References
Reference F5747C is the original factory code FIAB for this ECG patient cable with inspectable manifold and snap connection compatible with Fukuda Denshi devices, also registered under the distribution SKU Cahnos FIAB-F5747C: both designations identify the same product unit.
No official equivalence table authorising 1:1 replacement with cables from other manufacturers has been found in reliable sources: ECG patient cables are accessories specific to the equipment-side connector, the number of leads and the electrode attachment system, so any alternative must always be validated against the electrocardiograph’s technical data sheet.
| Reference FIAB | Electrode connection | Compatibility | Level |
|---|---|---|---|
| F5747RC | Snap (hook) | Fukuda Denshi | Family variant of the same cable (verify fit) |
| F5252C | Snap (hook) | Fukuda Denshi | Comparable by category; not interchangeable 1:1 |
| F6252 / F6747 / F6747R | 4 mm plug (socket) | Fukuda Denshi | Terminal variant; not interchangeable |
| F6747P / F6747RP | Pinch-type clamp | Fukuda Denshi | Terminal variant; not interchangeable |
| F5748RC / F5749RC | Snap (hook) | Burdick/Quinton and Siemens | Another platform; not interchangeable |
| F5746RC | Snap (hook) | Marquette, Hellige | Another platform; not interchangeable |
| F5737RC | Snap (hook) | Cardioline | Another platform; not interchangeable |
| F5738RC | Snap (hook) | Kenz | Another platform; not interchangeable |
Consult the technical department of Cahnos before considering alternatives in tenders.
5. Selection tips and variants of interest
Before placing the order, confirm that your electrocardiograph or monitor belongs to the Fukuda Denshi platform and check the terminal type of your electrodes: this reference features a snap connection (press stud / CLIP), suitable for the standard press-fit disposable ECG electrodes on the market. If your electrode stock uses a 4 mm plug or pinch-type clip, consider the FIAB variants of the same Fukuda Denshi platform (F6252 / F6747 / F6747R or F6747P / F6747RP series), subject to prior technical validation.
Take advantage of the inspectable manifold by carrying out periodic checks of the internal connections, snap terminals and cable insulation, especially before diagnostic tests or prolonged recordings. It is recommended to keep a spare cable per electrocardiograph so as not to interrupt clinical activity during maintenance, and to replace the assembly at any sign of deterioration or loss of signal quality. For hospital supplies, equipment fleets or tenders, contact the technical-commercial department of Cahnos to confirm exact compatibility with your equipment fleet and request a tailored quote.