Description
1. Product Presentation
We present the patient cable for electrocardiography Ref. F6726P/9 from FIAB, a professional spare part designed to connect the patient’s surface electrodes to the electrocardiographs of Siemens, Bosch and Custo Med equipment. It is an essential component in the monitoring and recording of 12-lead ECG, manufactured by FIAB SpA (Vicchio, Florence – Italy), one of the leading European manufacturers of cables and accessories for cardiac diagnostics.
Its configuration with an inspectable manifold and forceps termination allows simple maintenance and timely replacement of each lead, extending the service life of the assembly and reducing replacement costs in hospitals, clinics, cardiology practices and emergency departments. The sale is made on quotation.
2. Technical explanation of the equipment
In a standard electrocardiography system, the patient cable constitutes the bridge between the adhesive electrodes placed on the patient’s chest and limbs and the input of the electrocardiograph. Each lead (right limb, left limb, left leg and precordial leads) transmits a low-amplitude bioelectric signal that must reach the equipment without loss or interference.
This cable incorporates an inspectable manifold (inspectable manifold): a detachable connection box that allows checking the condition of the tracks and each output without disassembling the entire cable, facilitating rapid fault diagnostics and replacement of a single section if necessary. The patient-side termination is of the forceps (pinch) type, which attaches firmly and securely to forceps electrodes or pinch-type electrodes commonly used in clinical practice, ensuring stable contact during recording.
3. Technical Specifications
| Characteristic | Value |
|---|---|
| Reference FIAB | F6726P/9 |
| Manufacturer | FIAB SpA (Vicchio, Florence – Italy) |
| Product type | Patient cable for electrocardiograph (ECG) |
| Distributor (manifold) | Inspectable |
| Patient connection | Forceps (pinch type) |
| Compatibility | Siemens, Bosch, Custo Med |
| Packaging | 1 unit |
| Units per box (web) | 1 |
| Commercialisation | Budget-friendly (B2B sale) |
4. Equivalences and Cross-References
Reference F6726P/9 corresponds to the official catalogue of manufacturer FIAB as listed in its section on ECG patient cables with inspectable manifold and forceps-type connection. No equivalence table validated by the manufacturer has been found that cross-references this exact configuration with identical codes from other brands; any substitution must be verified field by field (type of connector to the equipment, forceps termination, number of leads and electrocardiograph compatibility) before use in tendering.
| Reference FIAB | Compatibility | Observations |
|---|---|---|
| F6726P/9 | Siemens, Bosch, Custo Med | This product: inspectable manifold, forceps connection |
| F6726P | Mortara, BTL | Same construction series, different compatibility |
| F6726P/HP | HP | Same construction series, different compatibility |
| F6726/PMAC | Macquarie | Same construction series, different compatibility |
| F6726/PNK33 | Nihon-Kohden | Same construction series, different compatibility |
| F6726RP | Cardioline, Schiller and others | Same series, extended compatibility range |
Consult our technical-commercial department before choosing a reference from another brand for this equipment.
5. Selection tips and variants of interest
Before placing your order, confirm the exact model of your Siemens, Bosch or Custo Med electrocardiograph and the type of input connector on the equipment, as well as the terminal you usually use with your electrodes (forceps, button or pin). The F6726P/9 cable uses forceps on the patient side, making it suitable for forceps-type electrodes.
The F6726 series from FIAB offers variants for different equipment on the market (Mortara/BTL, HP, Macquarie, Nihon-Kohden, and an RP version with extended compatibility), so that the same construction solution can be adapted to your fleet of electrocardiographs. If your equipment belongs to another manufacturer, let us know the model and we will advise you on the correct FIAB reference. For maintenance contracts, service provisions or volume purchases, contact the technical-commercial team at Cahnos.







Reviews
There are no reviews yet.