ECG patient cable with inspectable manifold and forceps connection for Hellige electrocardiographs · FIAB Ref. F6267/9P

Price on request

ECG patient cable with inspectable manifold and forceps (pinch) connection terminals, reference F6267/9P from the Italian manufacturer FIAB, designed for use with electrocardiographs and devices of the Hellige family. Its inspectable manifold allows visual verification of the connections and the condition of the wiring, facilitating maintenance and early detection of possible points of poor signal in the electrocardiography station. The forceps-type connection ensures quick and firm attachment to ECG electrodes, with stable signal transmission during recording. It is supplied in a pack of 1 unit and is sold on quotation; contact our technical-commercial team for supply conditions and exact compatibility with your equipment model.

International shipping. Import duties and taxes are payable by the recipient.

Reference
FIAB-F6267-9P
Brand
FIAB

Description

1. Introduction

The ECG patient cable Ref. F6267/9P from FIAB is the connection accessory that your cardiology, diagnostics or occupational medicine department needs to keep your Hellige electrocardiograph operational with optimal recording quality. Manufactured by FIAB S.p.A. (Vicchio, Florence, Italy), a European leader in electrocardiography accessories, this cable combines an inspectable manifold with forceps (pinch) terminals to ensure reliable signal acquisition, simple assembly and easy maintenance in day-to-day care.

2. Technical explanation

The patient cable is the element of the recording chain that transmits the electrocardiographic signal captured by the electrodes placed on the patient’s chest and limbs to the recording equipment. The signal chain is: electrode → forceps (pinch) terminal → individual lead → manifold → electrocardiograph connector.

The distinctive feature of this reference is its inspectable manifold: the area where the leads converge has a transparent cover or direct access that allows the technician to visually verify the condition of the connections, detect accumulation of dirt, corrosion or micro-cuts in the wiring without having to disassemble the assembly. This periodic inspection reduces the risk of artefacts, signal interruptions and false readings, extending the useful life of the cable. The forceps (PINCH) terminals are fixed by pressure onto the electrodes, ensuring a firm mechanical contact and stable signal transmission during recording.

3. Technical Specifications

The manufacturer’s catalogue specifications for reference F6267/9P are detailed below:

Characteristic Value
Reference FIAB F6267/9P
Packaging 1 unit
Units per box (web) 1
Compatible with Hellige
Parameter Specification
Brand FIAB (FIAB SpA, Vicchio, Florencia — Italia)
SKU Cahnos FIAB-F6267-9P
Product type Patient cable for electrocardiography (ECG)
Distributor Inspectable (inspectable manifold)
Patient connection Forceps (PINCH)
Compatibility Electrocardiographs and Hellige devices
Categories FIAB ECG | Patient Cables | Inspectable Manifold | Pinch
Presentation 1 unit
Sales condition On quotation (no fixed price)

4. Equivalences and Cross-References

Reference F6267/9P corresponds to the official factory code FIAB, verified in the manufacturer’s catalogue (fiab.it, path ECG > Patient Cables > Inspectable Manifold > Pinch). No official equivalence table has been found in reliable sources that would allow this reference to be substituted 1:1 by cables from other manufacturers: ECG patient cables are accessories specific to the connector and configuration of each equipment family, so any substitution must be validated field by field (type of manifold, number of leads, electrode terminal and equipment-side connector) against the technical data sheet of the Hellige electrocardiograph and of the alternative manufacturer. Always consult with the technical department of Cahnos before establishing an equivalence in tender documents or bids.

5. Selection tips and variants of interest

Confirm the exact model of your Hellige electrocardiograph and the type of equipment-side connector before placing the order. Also verify the terminal of your usual electrodes: this reference features a forceps (PINCH) connection, suitable for electrodes with clip/forceps connection; if your practice uses snap electrodes or tab (TAB) electrodes, consider the adapters and the complementary ECG electrode range from the Cahnos catalogue. Take advantage of the inspectable manifold to establish a periodic review of the wiring: visually inspect the connection points, the integrity of the insulation and the condition of the terminals, and replace the cable at any sign of deterioration or loss of signal quality. Product sold on quotation; for institutional volumes, supplies or tenders, contact our technical-commercial team quoting reference FIAB-F6267-9P and the model of your equipment.

Additional information

Brand

FIAB

Packaging

1 unit

Manufacturer reference

F6267/9P

Manufacturer

FIAB SpA (Vicchio, Florence, Italy)

Product type

Patient cable for electrocardiography (ECG)

Patient connection

Forceps (PINCH)

Compatibility

Electrocardiographs and Hellige devices

Sales condition

Under quotation

Presentacion

Unit