Description
1. Commercial Introduction
Complete or renew the wiring of your electrocardiograph with this kit of 10 replacement unipolar leads from the Italian manufacturer FIAB, reference F5388/KIT. It is the complete set of individual lead wires with a 4 mm male plug connector and protection against defibrillation discharge of 4.7 KOhm, designed to replace worn leads of ECG patient cables that use this connection system. Manufactured by FIAB SpA (Vicchio, Florence, Italy), it guarantees stable transmission of the electrocardiographic signal in cardiology clinics, primary care, emergency departments and functional diagnostic centres. Product sold on quotation: consult our technical-commercial team to formalise your B2B conditions.
2. Technical explanation of the equipment
The unipolar lead (individual lead wire) is the conductive wire that connects each electrode placed on the patient to the main cable or distributor of the electrocardiograph. In this reference, the patient end is fitted with a 4 mm male connector (banana plug), the classic coupling system for reusable clip electrodes and for numerous 10-lead ECG patient cables.
The distinguishing feature of this kit is its protection against defibrillation discharge of 4.7 KOhm: the protection circuit limits the energy that could be transmitted to the electrocardiograph during defibrillation, helping to safeguard the equipment’s electronics and maintaining signal fidelity in the recording. The kit includes the standard lengths and colours to fully configure the patient leads.
3. Technical specifications and tables
The manufacturer’s specifications and the main technical data for this lead kit are detailed below:
Manufacturer’s specifications
| Characteristic | Value |
|---|---|
| Reference FIAB | F5388/KIT |
| Packaging | 1 unit |
| Units per box (web) | 1 |
Available references
| Reference | Description |
|---|---|
| FIAB-F5388-KIT | SKU Cahnos of the kit of 10 leads, 4 mm plug connector, 4.7 KOhm protection |
| F5388/KIT | Official manufacturer reference FIAB |
Product technical data
| Parameter | Value |
|---|---|
| Brand | FIAB |
| Manufacturer / original distributor | FIAB SpA (Vicchio, Florence, Italy) |
| Product type | Kit of 10 replacement unipolar leads for ECG |
| Patient end connector | Male 4 mm (plug) |
| Protection against defibrillation discharge | 4.7 KOhm |
| Number of leads | 10 |
| Kit composition | 6 leads of 100 cm + 4 leads of 120 cm |
| Colours of the 100 cm leads | Red, yellow, green, brown, black, violet |
| Colours of the 120 cm leads | Green, yellow, black, red |
| Classification in FIAB catalogue | ECG > Patient Cables > Accessories |
| Sales unit | Under quotation |
4. Equivalences and Cross-References
The reference FIAB F5388/KIT corresponds to the kit of 10 unipolar leads with 4 mm male connector and 4.7 KOhm protection, marketed by Cahnos under the SKU FIAB-F5388-KIT; both references identify the same product and it is supplied in a pack of 1 unit. No official equivalence table has been found in reliable sources that would allow this reference to be substituted 1:1 by leads from other manufacturers: lead wires are specific accessories of the connection system (patient terminal type and connector on the main cable side), so they must always be checked against the technical data sheet of your electrocardiograph or patient cable. Within the FIAB catalogue, and always without automatic interchangeability, there are other comparable references by category and connection system:
| Reference FIAB | Connection | Protection |
|---|---|---|
| F5388/KIT | 4 mm plug | 4.7 KOhm (this product) |
| F5388R/KIT | 4 mm plug | 10 KOhm |
| F5386/KIT | Pinch | 4.7 KOhm |
| F5386R/KIT | Pinch | 10 KOhm |
| F5377/KIT | 4 mm plug | Without protection |
| F5399/KIT | Snap | Without protection |
5. Selection tips and variants of interest
Check the connection system of your patient cable or electrocardiograph: this reference is fitted with a 4 mm male connector (plug) at the patient end and is intended for 10-lead equipment that uses this termination. Confirm the protection level required by your equipment fleet: 4.7 KOhm (ref. F5388/KIT), 10 KOhm (ref. F5388R/KIT) or without protection (ref. F5377/KIT). If your wiring uses another type of terminal, consider the equivalent kit with pinch connection (ref. F5386/KIT with 4.7 KOhm or F5386R/KIT with 10 KOhm) or with snap connection (ref. F5399/KIT). It is recommended to periodically check the condition of the insulation, contacts and flexibility of the leads, replacing them at any sign of deterioration, breakage or loss of signal quality. As this is a product sold on quotation, contact the technical-commercial department of Cahnos to confirm exact compatibility with your equipment and obtain a formalised quotation under B2B conditions.





Reviews
There are no reviews yet.