Description
1. Introduction
The peripheral forceps electrode FIAB Ref. F9024ONI is the reference reusable solution for electrocardiographic recording in adult patients with obesity. Its forceps geometry is designed for larger-diameter limbs (wrists and ankles), ensuring a firm, stable and comfortable grip throughout the recording.
Manufactured by FIAB SpA (Vicchio, Florence, Italy), this electrode is part of the brand’s range of reusable peripheral electrodes and is ideal for cardiology practices, emergency departments, occupational medicine units and hospitals that need to replace or expand their supply of forceps for their electrocardiographs with guarantees of durability and hygiene.
2. Technical explanation of the electrode
Limb forceps are peripheral electrodes that are attached to the patient’s wrists and ankles to capture the electrocardiographic signal from the limb leads (I, II, III, aVR, aVL and aVF). This model incorporates a nickel-plated sensor, a metallic coating resistant to continuous use that offers stable electrical contact and a long service life, making it a robust, low-maintenance alternative to single-use electrodes.
Its forceps fixation system with an opening adapted to patients with obesity ensures adequate contact pressure without compressing the limb, minimising motion artefacts and promoting a clean trace even during prolonged recordings. As a reusable electrode, proper cleaning and disinfection after each use is sufficient to maintain optimal performance over many working cycles.
3. Technical Specifications
| Characteristic | Value |
|---|---|
| Reference FIAB | F9024ONI |
| Packaging | 4 units |
| Units per box (web) | 4 |
| Brand | FIAB |
| Manufacturer | FIAB SpA (Vicchio, Florence, Italy) |
| Type | Reusable peripheral forceps electrode for ECG (adult with obesity) |
| Sensor | Nickel-plated |
| Application | Resting and monitoring ECG; peripheral limb leads |
| Category FIAB | ECG > Reusable Electrodes > Peripheral > Adult Clamps |
| Sale | Subject to quotation (sold in complete boxes) |
Available references
| Reference | Description | Sales unit |
|---|---|---|
| F9024ONI | Peripheral forceps electrode for limbs of adults with obesity, nickel-plated sensor, for ECG | Box of 4 units |
4. Equivalences and Cross-References
There is no 1:1 equivalence table validated by the manufacturer relating reference F9024ONI to third-party codes. Within the FIAB family of reusable peripheral forceps itself, the same range offers variants that allow the size and sensor to be adapted to each service: the standard adult version F9024SSC (Ag/AgCl sensor, available at Cahnos), the version for patients with obesity with silver chloride sensor F9024OSSC, the nickel-plated adult version F9024NI and the paediatric version F9023SSC. Remember that, for patients with obesity, the specific size that ensures a firm grip must always be selected.
As a comparative reference by category (adult limb forceps with universal connection, not 1:1 interchangeable), the following are cited, verified in their manufacturers’ official catalogues: Medke K9205, Lessa 99.100.00, Moretti DRV170, Igibsa 14-EP01, Upnmed 40419A and Philips 40494E. Note that these references generally mount a silver chloride sensor (Ag/AgCl), so before any replacement, the sensor material, forceps dimensions, patient cable connector and regulatory classification must be confirmed with the technical-commercial department of Cahnos.
5. Selection tips and variants of interest
To choose the right forceps for your equipment fleet, first check the patient cable terminal of your electrocardiograph or monitor: the FIAB range with universal connection accepts 4.0 mm banana socket, 3.0 mm DIN plug and snap via its screw and clip system, covering virtually all equipment on the market.
As for the sensor, the nickel-plated finish of this reference offers a durable and economical surface; if your service requires superior signal quality, with lower polarisation and minimal distortion, the same size is available with a silver chloride sensor (SSC variant). To complete the service’s supply, combine these forceps with chest suction electrodes, patient cables and unipolar leads from the same range.
Given its reusable nature, always follow the manufacturer’s cleaning and disinfection instructions and periodically check the condition of the nickel-plated coating to maintain optimal signal quality and extend the electrode’s service life. For institutional orders, tenders or continuous supply contracts, contact our technical-commercial department to confirm compatibility and a formal quotation.





Reviews