Description
1. Introduction
The Pencan® 22G × 3 1/2″ (0.7 × 88 mm) spinal needle with introducer from B. Braun is the reference choice in anaesthesiology and operating theatre departments when seeking access to the subarachnoid space with a high-flow, safe and minimally traumatic gauge. Its atraumatic pencil-point bevel is indicated for spinal anaesthesia, lumbar spinal anaesthesia and diagnostic lumbar puncture, especially when the aim is to minimise the risk of post-dural puncture headache (PDPH). This 88 mm reference, supplied with an introducer, is the largest-gauge variant in the Pencan range, the most rigid and with the highest injection and CSF reflux flow, ideal when a rapid response of cerebrospinal fluid drip or the administration of more viscous solutions is required.
2. Technical explanation of the procedure
Spinal or subarachnoid anaesthesia involves the administration of a local anaesthetic into the cerebrospinal fluid (CSF), achieving a rapid, deep and reliable sensory and motor block, suitable for abdominal, urological, trauma and lower limb surgery. Unlike cutting-bevel needles such as the Quincke type, the pencil point separates the dural fibres rather than cutting them, which promotes spontaneous sealing of the dura mater and significantly reduces the incidence of post-puncture headache and neurological injury.
The 22G (0.7 mm) gauge offers the largest diameter in the Pencan family, with a reflux and injection flow far superior to the 25G and 27G gauges, and a rigidity that facilitates advancement through ligamentous planes, being especially valued in adult patients and in techniques requiring rapid confirmation of cannulation. The transparent hub with glass prism allows immediate identification of CSF reflux (the prism shines silver before reflux and becomes transparent as the fluid passes), ensuring correct positioning before injection. The obturator stylet with colour-coded mandrel ensures lumen patency and precise orientation during insertion, while the included introducer protects the needle during advancement through tissues and improves control and tactile sensitivity of the puncture.
3. Technical Specifications
| Brand / Line | B. Braun – Pencan® (spinal anaesthesia range, pencil-point) |
| Reference (SKU) | 4502035-13 (manufacturer ref. 254502035-13) |
| Gauge | 22G (outer diameter 0.70 mm) |
| Length | 88 mm (3 1/2 inches) |
| Tip type | Atraumatic pencil point |
| Introducer | Included |
| Material | Medical-grade stainless steel cannula; stainless steel mandrel; transparent hub with prism; colour-coded mandrel |
| Application | Spinal anaesthesia and diagnostic lumbar puncture |
| Sterility | Sterile, single-use, individual packaging (blister) |
| Connection | Standard Luer hub |
| Presentation | Box of 25 units |
Pencan pencil-point range (official B. Braun references):
| Gauge | Length | Introducer | Packaging | Manufacturer ref. |
|---|---|---|---|---|
| 27G | 88 mm (3 1/2″) | No | 25 units | 254502027-01 |
| 27G | 88 mm (3 1/2″) | Yes | 25 units | 254502051-13 |
| 27G | 103 mm (4″) | Yes | 25 units | 254502124-13 |
| 27G | 120 mm (4 3/4″) | No | 25 units | 254502132-13 |
| 25G | 88 mm (3 1/2″) | No | 25 units | 254502019-01 |
| 25G | 88 mm (3 1/2″) | Yes | 25 units | 254502043-13 |
| 25G | 103 mm (4″) | Yes | 25 units | 254502116-13 |
| 22G | 88 mm (3 1/2″) | Yes | 25 units | 254502035-13 |
4. Equivalences and Cross-References
B. Braun does not publish an official cross-reference table for the Pencan range; equivalences between brands must be verified field by field before use in tenders. By tip family (atraumatic pencil point, 22G gauge, with introducer), the following references from other manufacturers are comparable by category (not interchangeable 1:1):
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence Level | Technical Differences / Remarks |
|---|---|---|---|---|
| BD | Whitacre Pencil Point 22G × 3 1/2″ (0.70 × 90 mm), black hub | 405010 | Comparable by category (not interchangeable 1:1) | Same atraumatic tip family and 22G gauge; slightly longer length (90 mm vs 88 mm); usual presentation in boxes of 10-25 units depending on market |
| BD | Whitacre Pencil Point Spinal NRFit 22G × 3 1/2″ (0.70 × 90 mm) | 401995 | Comparable by category (not interchangeable 1:1) | Same atraumatic tip family and 22G gauge; NRFit connector (ISO 80369-6) versus the standard Luer cone of the Pencan; length 90 mm vs 88 mm |
Technical warnings: the pencil point (Pencan, Whitacre, Sprotte) is not equivalent to the cutting Quincke-type point (e.g., the Spinocan® line from B. Braun or BD Quincke): the incidence of post-puncture headache is different and they must not be substituted for each other without clinical evaluation. Other brands with a homologous pencil-point family in 22G gauge (Dahlhausen pencil point series, Vygon Whitacre, Pajunk Sprotte) are comparable by category; their specific codes are pending confirmation with each manufacturer before citing them. Always verify before substitution: gauge, length, tip type, presence of introducer, connector (Luer vs. NRFit, ISO 80369-6) and sterility of the actual product. There is no manufacturer-validated equivalence table; consult the technical department before use in tenders.
5. Selection tips and variants of interest
The Pencan 22G × 88 mm with introducer is the largest-gauge variant in the range, recommended when maximum CSF reflux and injection flow and greater cannula rigidity are prioritised, in adult lumbar approaches with standard insertion path. If you wish to further minimise dural trauma, consider the finer gauges in the same family: Pencan 25G × 88 mm without introducer (Ref. 4502019-01), with introducer (Ref. 4502043-13) or in long version (Ref. 4502116-13), and Pencan 27G × 88 mm without introducer (Ref. 4502027-01) or with introducer (Ref. 4502051-13). For patients with greater adipose panniculus or longer insertion path, consider the long formats of 103 mm or 120 mm available in the range. Verify the integrity of the sterile packaging before each use and dispose of the needle after a single puncture in an approved container for sharps and cutting waste. For volume orders, supply contracts or tenders, contact the technical-commercial team at Cahnos.




Reviews
There are no reviews yet.